Item No.:
*
|
|
Site:
Other-MEDICAL
|
|
Violation:
THE GASTROINTESTINAL ILLNESS SURVEILLANCE LOGS DID NOT INCLUDE CRUISES WHERE NO PASSENGERS OR CREW WERE ILL.
|
|
Recommendation:
Gastrointestinal illness logs must be completed even when there are zero cases.
|
|
|
Item No.:
06
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
THE CALIBRATION OF THE AUTOMATED CHLORINE ANALYZER WAS NOT BEING DONE BEFORE EACH BUNKERING. THE HOURLY CHECKS OF BUNKER CHLORINATION WAS NOT RECORDED.
|
|
Recommendation:
5.2.1.2.4
Halogen analyzer-chart recorders used in lieu of manual tests and logs shall be calibrated at the beginning of bunkering or production, and the calibration shall be recorded on the chart or in a log book.
5.2.1.2.2
Free residual halogen monitoring shall be performed at least hourly during the bunkering of potable water and performed at least once every 4 hours during the onboard production of potable water.
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
A BACKFLOW PREVENTER WAS NOT INSTALLED ON THE HIGH SALINITY DISCHARGE LINE FROM THE EVAPORATION PRODUCTION SYSTEM.
|
|
Recommendation:
A backflow preventer should be provided on the high salinity discharge from the production system.
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
POTABLE WATER TANKS DID NOT HAVE SAMPLE VALVES. POTABLE WATER LINES WERE NOT STRIPED BLUE.
|
|
Recommendation:
5.3.1.2.2
Potable water tanks shall have sample valves which are turned down.
5.3.2.1.1
Potable water piping shall be painted light blue or striped with 15 cm (6 inches) light blue bands or a light blue stripe at fittings on each side of partitions, decks, and bulkheads and at intervals not to exceed 5 m (15 feet) in all spaces, except where the decor would be marred by such markings.
|
|
|
Item No.:
07
|
|
Site:
Other-WATER
|
|
Violation:
THE POTABLE WATER TANKS ARE SKIN TANKS. AN INCOMPLETE VARIANCE REQUEST WAS SUBMITTED BY THIS VESSEL. THE POTABLE WATER TANKS ARE EQUIPPED WITH SALINITY METERS BUT ARE STILL NOT PROVIDED WITH AUDIBLE ALARMS.
|
|
Recommendation:
Submit a variance request that specifies that salinity meters, and audible alarms will be provided for each potable water tank. The alarms must sound in an area that is manned 24 hours/day. As part of the variance request a HACCP plan must be submitted that details what will be done should an alarm sound.
|
|
|
Item No.:
06
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
NO AUDIBLE ALARM FOR LOW CHLORINE IN THE DISTRIBUTION SYSTEM WAS PROVIDED. A BACKUP HALOGEN PUMP WITH AN AUTOMATIC SWITCH-OVER WAS NOT PROVIDED ON THE DISTRIBUTION SYSTEM. THE CHLORINE ANALYZER CHARTS DID NOT HAVE A RANGE FROM 0.0 TO 5.0 PPM. THE ANALYZER CHARTS WERE NOT BEING CHANGED DAILY.
|
|
Recommendation:
The distribution system should be provided with an audible low-level alarm that sounds in an area that is manned 24 hours/day. The water distribution system should be provided with a backup halogen pump with an automatic switch over. The chlorine analyzer charts should have a range from 0.0 to 5.0 ppm and the analyzer charts should be changed daily.
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
A COMPREHENSIVE CROSS-CONNECTION CONTROL PROGRAM HAS NOT BEEN DEVELOPED FOR THIS VESSEL.
|
|
Recommendation:
5.7.1.1.3
The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present:
(1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
|
|
|
Item No.:
41
|
|
Site:
Other-VENTILATION
|
|
Violation:
NO VENTILATION MAINTENANCE PLAN WAS AVAILABLE.
|
|
Recommendation:
9.2.1.2.3
Vessels shall have a plan to inspect and maintain heating, ventilation, and air conditioning systems in accordance with manufactures recommendations and industry standards.
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
BACKFLOW PREVENTION DEVICES WERE NOT PROVIDED ON THE POTABLE WATER SYSTEM AS DESCRIBED IN 5.7 OF THE OPERATIONS MANUAL.
|
|
Recommendation:
5.7.1.2.1
Backflow preventers shall be installed when air gaps are impractical or when water under pressure is required.
|
|
|
Item No.:
06
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
NO MICROBIOLOGICAL SAMPLING WAS BEING CONDUCTED.
|
|
Recommendation:
5.1.1.2.1
Where available, the vessel shall have a copy of the most recent microbiologic report from each port before bunkering potable water to verify that the water meets potable standards.
5.1.1.2.3
These records shall be maintained on the vessel for 12 months and shall be available to the VSP for review during inspections.
5.6.1.1.1
A minimum of four potable water samples per month shall be collected and analyzed for the presence of Escherichia coli. Samples shall be collected randomly from locations forward, aft, upper, and lower decks of the vessel.
5.6.1.1.2
Samples shall be analyzed utilizing a method accepted in Standard Methods for the Examination of Water and Wastewater.
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
A SAMPLE POINT FOR TESTING CHLORINE IN THE BUNKERED WATER WAS NOT PROVIDED.
|
|
Recommendation:
A sampling point for testing chlorine should be provided.
5.2.1.2.7
Water samples for halogen testing shall be obtained from a sample cock located on the bunker or production water line at least 3 m (10 feet) after the halogen injection point and before the storage tank.
|
|
|
Item No.:
10
|
|
Site:
Other-WHIRLPOOL SPA
|
|
Violation:
THE WHIRLPOOL SPA DID NOT HAVE AN AUTOMATED DOSING SYSTEM FOR HALOGEN AND PH ADJUSTMENT.
|
|
Recommendation:
Provide analyzer controlled chemical dosing for both pH and disinfection.
|
|
|
Item No.:
*
|
|
Site:
Other-GENERAL COMMENT
|
|
Violation:
ENSURE ALL ITEMS NOTED DURING CONSTRUCTION INSPECTION OF MAY 1, 2001 ARE COMPLETED.
|
|
Recommendation:
|
|
|
Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: SAFARI QUEST - CAS - [05/25/2002] .
|
|
Recommendation:
|
|
|
Item No.:
33
|
|
Site:
Other-GALLEY
|
|
Violation:
BULKHEADS AND DECKHEADS WERE NOT EASILY CLEANABLE.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
|
|
|
Item No.:
32
|
|
Site:
Other-GALLEY
|
|
Violation:
THERE WAS NO COVER FOR THE WASTE RECEPTACLE LOCATED IN THE GALLEY.
|
|
Recommendation:
7.7.2.1.3
Receptacles and waste-handling containers shall be kept covered when not in continuous use and after they are filled.
|
|
|
Item No.:
27
|
|
Site:
Other-GALLEY
|
|
Violation:
SOME OF THE INTERIORS OF THE CABINETS WERE SOILED.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Other-GALLEY
|
|
Violation:
SOME OF THE INTERIORS OF THE CABINETS WERE NOT EASILY CLEANABLE.
|
|
Recommendation:
7.4.2.2.6
Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
26
|
|
Site:
Other-GALLEY
|
|
Violation:
THE INTERIORS OF THE REACH-IN REFRIGERATOR AND FREEZER WERE SOILED.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Other-GALLEY
|
|
Violation:
THE INTERIOR SPACE OF THE MICROWAVE WAS SOILED WITH A FOOD RESIDUE.
|
|
Recommendation:
7.5.5.1.7
Cooking and baking equipment shall be cleaned as follows:
(1) The food-contact surfaces of cooking and baking equipment shall be cleaned at least every 24 hours.
(2) The cavities and door seals of microwave ovens shall be cleaned at least every 24 hours by using the manufacturer's recommended cleaning procedure.
|
|
|
Item No.:
21
|
|
Site:
Other-GALLEY
|
|
Violation:
THE PLATE HOLDER WAS NOT EASILY CLEANABLE.
|
|
Recommendation:
7.4.2.2.6
Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Other-GALLEY
|
|
Violation:
THERE WERE FOOD PARTICLES IN THE BOTTOM OF THE PLATE HOLDER.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
20
|
|
Site:
Other-GALLEY
|
|
Violation:
THE CUTTING BOARDS WERE PITTED AND SCORED.
|
|
Recommendation:
7.4.5.1.3
Surfaces such as cutting blocks and boards that are subject to scratching and scoring shall be resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
|
|
|
Item No.:
26
|
|
Site:
Other-GALLEY
|
|
Violation:
THE CUTTING BOARDS WERE STAINED AND SOILED WITH A FOOD RESIDUE.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Other-AFT REFRIGERATOR
|
|
Violation:
THERE WAS MOLD GROWTH ON THE GASKETS OF THE AFT REFRIGERATOR.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
19
|
|
Site:
Other-AFT STORAGE
|
|
Violation:
THERE WAS RAW MEAT STORED WITH RAW VEGETABLES IN AN IGLOO ICE CHEST.
|
|
Recommendation:
7.3.3.2.1(1)
Food shall be protected from cross-contamination by:
(1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food including other raw animal food such as fish for sushi or molluscan shellfish, or other raw ready-to-eat food such as vegetables, and cooked ready-to-eat food; so products do not physically touch, and so as to prevent dripping of one product into another.
|
|
|
Item No.:
33
|
|
Site:
Other-PROVISIONS
|
|
Violation:
THE DECK IN THIS AREA WAS COVERED WITH SOME FOOD PARTICLES.
|
|
Recommendation:
7.7.4.2.1
Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
|
|
|
Item No.:
18
|
|
Site:
Other-PROVISIONS
|
|
Violation:
THERE WAS AN AVOCADO THAT WAS SPOILED.
|
|
Recommendation:
7.3.3.2.1.1
Food shall be protected from cross-contamination by: (7) Separating damaged, spoiled, or recalled food being held on the vessel.
|
|
|
Item No.:
20
|
|
Site:
Other-GALLEY
|
|
Violation:
INTERIORS SPACES OF THE OVENS WERE NOT EASILY CLEANABLE.
|
|
Recommendation:
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
16
|
|
Site:
Other-GALLEY
|
|
Violation:
LARGE BULK SOFT CHEESES WERE NOT DATE MARKED AS REQUIRED AFTER OPENING.
|
|
Recommendation:
7.3.5.3.2
Refrigerated, ready-to-eat, potentially hazardous food:
(2) A container of refrigerated, ready-to-eat potentially hazardous food prepared and packaged by a food processing plant shall be clearly marked, at the time the original container is opened, to indicate the date by which the food shall be consumed which is, including the day the original container is opened, 7 calendar days or fewer after the original container is opened.
|
|
|
Item No.:
33
|
|
Site:
Other-BAR
|
|
Violation:
THE DECK UNDERNEATH THE ICE MACHINE WAS SOILED.
|
|
Recommendation:
7.7.4.2.1
Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
|
|
|
Item No.:
27
|
|
Site:
Other-BAR
|
|
Violation:
THE GASKETS ON THE BAR COOLER WERE SOILED WITH FOOD RESIDUE.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|