Cruise Ship: Safari Quest Cruise Line: Un-Cruise Adventures Inspection Date: 08/10/2002 Inspection Score: 87
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE HALOGEN ANALYZER-CHART RECORDER WAS NOT INSTALLED AT A DISTANT POINT IN THE POTABLE WATER DISTRIBUTION SYSTEM. IT WAS INSTALLED IN THE ENGINE ROOM. THE HALOGEN ANALYZER-CHART RECORDER CHARTS DID NOT HAVE A RANGE OF O.O PPM TO 5.0 PPM. THE CHARTS WERE NOT CONSISTENTLY DATED AND INITIALLED ON A DAILY BASIS. THERE WERE DATES MISSING AND SOME CHARTS WERE NOT DATED OR INITIALED. IN ADDITION, SOME CHARTS HAD THE SAME DATES. THE DAILY CALIBRATION OF THE HALOGEN ANALYZER CHART-RECORDER WAS NOT RECORDED ON THE CHARTS OR IN A LOG.
Recommendation: 5.5.1.1.1 A halogen analyzer-chart recorder shall be installed at a distant point in the potable water distribution system where a significant water flow exists. 5.5.2.1.1 Halogen analyzer-chart recorder charts shall have a range of 0.0 to 5.0 mg/L (ppm) and have a recording period of 24 hours. 5.5.2.2.1 Halogen analyzer-chart recorder charts shall be changed, initialed, and dated daily. Charts shall contain notations of any unusual water events in the potable water system. 5.5.1.2.1 The halogen analyzer-chart recorder shall be properly maintained, operated, and calibrated daily in accordance with the manufacturer's instructions. 5.5.1.2.2 The calibration shall be recorded on the chart or in a log book.
Item No.: 07
Site: Other-POTABLE WATER
Violation: THE VESSEL HAS TWO POTABLE WATER TANKS. BOTH TANKS ARE SKIN TANKS. THE VESSEL IS IN THE PROCESS OF COMPLETING THE WORK TO FULFILL THE VARIANCE REQUEST. THE SALINITY METERS AND ALARMS WERE IN PLACE. A HACCP PLAN ON WHAT TO DO SHOULD AN ALARM SOUND WAS NOT AVAILABLE.
Recommendation: 5.3.1.1.1 Potable water tanks shall not share a common wall with the hull of the vessel or with tanks containing non-potable water or other liquids.
Item No.: 08
Site: Other-POTABLE WATER
Violation: A COMPREHENSIVE CROSS-CONNECTION CONTROL PROGRAM (PLAN) HAS NOT BEEN DEVELOPED FOR THIS VESSEL. A HOSE WAS CONNECTED TO A THREADED HOSE-BIB IN THE ENGINE ROOM UNDER THE STRB GENERATOR WITHOUT A BACKFLOW PREVENTION DEVICE. THE FILL LINE FOR THE HOT TUB WAS NOT FITTED WITH A BACKFLOW PREVENTION DEVICE.
Recommendation: 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems. 5.7.1.2.1 Backflow preventers shall be installed when air gaps are impractical or when water under pressure is required.
Item No.: 08
Site: Other-POTABLE WATER
Violation: MAINTENANCE RECORDS INCLUDING CLEANING AND DISINFECTION WERE NOT AVAILABLE FOR THE POTABLE WATER TANKS.
Recommendation: 5.3.4.1.2 Potable water tanks shall be inspected, cleaned, and disinfected during dry docks and wet docks, or every 2 years, whichever is less. 5.3.4.1.3 Documentation of the cleaning shall be maintained for 12 months and shall be available to the VSP for review during inspections.
Item No.: 08
Site: Other-POTABLE WATER
Violation: SAMPLE VALVES WERE NOT INSTALLED ON THE POTABLE WATER TANKS.
Recommendation: 5.3.1.2.2 Potable water tanks shall have sample valves which are turned down.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE POTABLE WATER FILLING LINE WAS NOT LABELED. THE CAP FOR THE FILL LINE WAS NOT SECURED WITH A NON-CORRODING CHAIN.
Recommendation: 5.3.2.1.5 Each potable water filling line shall be painted light blue and clearly marked "POTABLE WATER FILLING" in letters at least 13 mm (0.5 inch) high, stamped on a non-corrosive label plate or the equivalent and located at or near the point of hose connection. 5.3.2.1.4 The potable water filling line shall have a screw cap or plug fastened by a non-corroding chain to an adjacent bulkhead or surface in such a manner that the cap or plug shall not touch the deck when hanging free.
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE DISTRIBUTION SYSTEM WAS NOT PROVIDED WITH A BACK-UP HALOGEN PUMP WITH AN AUTOMATIC SWITCHOVER SHOULD THE PRIMARY PUMP FAIL.
Recommendation: 5.4.1.2.3 At least one backup halogen pump shall be available with automatic switchover to maintain the free residual halogen in the event that the primary pump fails.
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE LOW LEVEL ALARM FOR HALOGEN IN THE DISTRIBUTION SYSTEM IS IN THE PROCESS OF BEING INSTALLED. WORK ON THIS HAS NOT YET BEEN COMPLETED.
Recommendation: Complete this work as soon as possible.
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE CALIBRATION OF THE BUNKER SYSTEM ANALYZER WAS NOT RECORDED AS REQUIRED.
Recommendation: 5.2.1.2.4 Halogen analyzer-chart recorders used in lieu of manual tests and logs shall be calibrated at the beginning of bunkering or production, and the calibration shall be recorded on the chart or in a log book.
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE LATEST MICROBIOLOGIC TEST RESULTS FOR THE PORT WATER WAS NOT AVAILABLE. FOUR SAMPLES WERE NOT COLLECTED ON THE VESSEL EACH MONTH AND TESTED FOR THE PRESENCE OF E. COLI.
Recommendation: 5.1.1.2.1 Where available, the vessel shall have a copy of the most recent microbiologic report from each port before bunkering potable water to verify that the water meets potable standards. 5.1.1.2.3 These records shall be maintained on the vessel for 12 months and shall be available to the VSP for review during inspections. 5.6.1.1.1 A minimum of four potable water samples per month shall be collected and analyzed for the presence of Escherichia coli. Samples shall be collected randomly from locations forward, aft, upper, and lower decks of the vessel. 5.6.1.1.2 Samples shall be analyzed utilizing a method accepted in Standard Methods for the Examination of Water and Wastewater. 5.6.1.2.1 Sample results shall be maintained with the halogen analyzer-chart recorder charts, shall be retained for at least 12 months, and shall be available to the VSP for review during inspections.
Item No.: 10
Site: Other-WHIRLPOOL SPA
Violation: AN AUTOMATED HALOGENATION SYSTEM WAS NOT PROVIDED. DURING MANUAL TESTING THE HALOGEN RESIDUAL WAS NOT TESTED HOURLY. THE NEW HALOGEN ANALYZER-CHART RECORDER WAS NOT CALIBRATED DAILY AND WAS OUT OF INK AT THE TIME OF THE INSPECTION. THE RAISING OF THE CHLORINE RESIDUAL TO 10 PPM FOR 1 HOUR WAS NOT CONSISTENTLY CONDUCTED AT THE END OF THE DAY. THE WHIRLPOOL WAS BEING EMPTIED WEEKLY RATHER THAN DAILY AS REQUIRED.
Recommendation: 6.3.1.2.1 The whirlpool spa water shall be changed daily. 6.3.2.1.1 The free residual halogen shall be increased to at least 10.0 mg/L (ppm) in whirlpool spas and circulated for at least 1 hour at the end of each day. 6.3.2.1.3 Halogenation systems shall be operated and maintained in good repair in accordance with the manufacturer's recommendations. Provide an automated halogenation system for the whirlpool spa. 6.3.2.2.3 Halogen analyzer-chart recorders used in lieu of manual tests and logs shall be calibrated daily, and the calibration shall be recorded on the chart or in a log book. 6.3.2.2.2 Residual halogen logs shall be maintained with residuals measured and recorded hourly during operation.
Item No.: 01
Site: Other-MEDICAL
Violation: DURING THE 07/27-08/03/2002 CRUISE 3 OUT OF 18 PASSENGERS WERE LISTED AS ILL IN THE GASTROINTESTINAL ILLNESS LOG. THE VESSEL DID NOT MAKE A SPECIAL REPORT FOR THIS CRUISE.
Recommendation: 4.2.2.1.1 The master, or designated corporate representative, of a vessel with an international itinerary destined for a U.S. port shall submit a special report at any time during a cruise, including between two U.S. ports, when: (1) The cumulative percentage of reportable cases entered in the gastrointestinal illness surveillance log, reaches 2% among passengers or 2% among crew; and (2) The vessel is within 15 days of expected arrival at a U.S. port. 4.2.2.1.2 Daily reports of illness status shall be submitted as requested by the VSP following the initial submission of a special report. 4.2.2.2.1 A telephone notification to the VSP shall accompany a special 2% report.
Item No.: 33
Site: Other-FOOD SERVICE GENERAL
Violation: THE DECKS, BULKHEADS, AND DECKHEADS WERE DIFFICULT TO CLEAN DUE TO THEIR CONSTRUCTION.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning. 7.7.4.1.3 Bulkhead and deck junctures shall be coved. 7.7.4.1.4 Bulkheads and deckheads shall have smooth, hard finishes, and light colored surfaces. 7.7.4.1.8 Surfaces subject to routine splashes, spillage or other soiling during normal use shall have easily cleanable features.
Item No.: 21
Site: Other-FOOD SERVICE GENERAL
Violation: THE NON-FOOD CONTACT SURFACES OF EQUIPMENT WERE DIFFICULT TO CLEAN DUE TO GAPS, OPEN SEAMS, AND OTHER FEATURES.
Recommendation: 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 20
Site: Other-FOOD SERVICE GENERAL
Violation: THE FOOD CONTACT SURFACES OF EQUIPMENT WERE DIFFICULT TO CLEAN DUE TO GAPS, OPEN SEAMS, EXPOSED COILS AND OTHER FEATURES. DOMESTIC EQUIPMENT WAS NOTED AS FOLLOWS: BAR-DOMESTIC REFRIGERATOR GALLEY-DOMESTIC TOASTER, RICE COOKER, MIXER, FREEZER, AND REFRIGERATOR.
Recommendation: 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches. 7.4.2.5.1 Food-contact surfaces of food equipment shall comply with American National Standards Institute (ANSI) or other internationally accredited food-equipment sanitation standards for materials, design, and construction.
Item No.: 38
Site: Other-GALLEY
Violation: AN ADEQUATE SPACE WAS NOT PROVIDED FOR STORING ITEMS SUCH AS BROOMS, MOPS, AND BUCKETS. BROOMS AND MOPS WERE STORED ON THE DECK BETWEEN THE FREEZER AND THE BULKHEAD.
Recommendation: 7.7.7.1.2 Maintenance tools such as mops, brooms, and similar items shall be stored in a designated locker so they do not contaminate food; food-contact surfaces of utensils; and equipment; linens, and single-service and single-use articles. 7.7.7.1.3 Maintenance tools such as mops, brooms, and similar items shall be stored in an orderly manner that facilitates cleaning of the area used for storing the maintenance tools. 7.7.7.1.4 After use, mops shall be placed in a position that allows them to air-dry without soiling walls, equipment, or supplies.
Item No.: 19
Site: Other-GALLEY
Violation: RAW SHELL EGGS WERE STORED OVER READY-TO-EAT FOODS IN THE REACH-IN REFRIGERATOR. AN OPEN PACKAGE OF HOT DOGS WAS STORED DIRECTLY ON PACKAGES OF RAW BACON.
Recommendation: 7.3.3.2.1(1) Food shall be protected from cross-contamination by: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food including other raw animal food such as fish for sushi or molluscan shellfish, or other raw ready-to-eat food such as vegetables, and cooked ready-to-eat food; so products do not physically touch, and so as to prevent dripping of one product into another.
Item No.: 30
Site: Other-GALLEY
Violation: A "WASH HANDS OFTEN" SIGN WAS NOT POSTED OVER THE HANDWASH SINK.
Recommendation: 7.7.1.1.7 A sign stating "WASH HANDS OFTEN" in a language that the food employees understand shall be posted over handwashing sinks.
Item No.: 21
Site: Other-GALLEY
Violation: RAW WOOD WAS NOTED UNDER THE CLEAN RAMP OF THE WAREWASH AREA.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 40
Site: Other-GALLEY
Violation: AN OPEN DOOR TO THE EXTERIOR WAS NOTED THAT WAS NOT PROVIDED WITH A SCREEN.
Recommendation: 8.2.1.1.2 Entry points where pests may enter the food areas shall be protected.
Item No.: 22
Site: Other-GALLEY/BAR
Violation: A TEST KIT OR TEST STRIPS WERE NOT PROVIDED FOR TESTING THE HALOGEN RESIDUAL IN THE WAREWASH MACHINE AND SANITIZING BUCKETS.
Recommendation: 7.5.3.3.1 A test kit or other device that accurately measures the concentration in mg/L (ppm) of sanitizing solutions shall be provided.
Item No.: 31
Site: Other-GALLEY
Violation: THE SANITIZING SOLUTION BOTTLE FOR THE WAREWASH UNIT WAS NOT LABLED.
Recommendation: 7.6.1.1.1 Original containers of poisonous or toxic materials and personal-care items shall bear a legible manufacturer's label.
Item No.: 33
Site: Other-GALLEY
Violation: THE DECK WAS SOILED UNDER EQUIPMENT.
Recommendation: 7.7.4.2.1 Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
Item No.: 19
Site: Other-GALLEY
Violation: MEASURING CUPS WERE STORED IN THE FLOUR AND SUGAR WITH THE HANDLES IN CONTACT WITH THE FOOD.
Recommendation: 7.3.3.4.2.1 During pauses in food preparation or dispensing, food preparation and dispensing utensils shall be stored: (1) In the food with their handles above the top of the food and the container.
Item No.: 21
Site: Other-GALLEY
Violation: CARBOARD CONTAINERS WERE RE-USED TO STORE ITEMS SUCH AS PLASTIC BAGS.
Recommendation: 7.4.2.1.2 Nonfood-contact surfaces of equipment and utensils shall be designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
Item No.: 26
Site: Other-GALLEY
Violation: THE OVENS WERE ENCRUSTED WITH FOOD RESIDUE. THESE OVENS WERE SAID TO BE CLEANED WEEKLY.
Recommendation: 7.5.5.1.7 Cooking and baking equipment shall be cleaned as follows: (1) The food-contact surfaces of cooking and baking equipment shall be cleaned at least every 24 hours. (2) The cavities and door seals of microwave ovens shall be cleaned at least every 24 hours by using the manufacturer's recommended cleaning procedure.
Item No.: 27
Site: Other-GALLEY
Violation: THE DUCT FOR THE DOWN-DRAFT HOOD WAS DUST LADEN AND SOILED.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 20
Site: Other-GALLEY
Violation: THE INDUCTION COOK-TOP WAS CRACKED.
Recommendation: 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 28
Site: Other-GALLEY
Violation: THE UTENSIL DRAWERS AND CONTAINERS WERE SLIGHTLY SOILED. THE BOTTOM OF THE PLATE HOLDER WAS SOILED.
Recommendation: 7.5.7.3.1 Cleaned equipment and utensils, laundered linens, and single-service and single-use articles shall be stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 19
Site: Other-DRY STORES
Violation: COFFEE WAS STORED UNDER THE CLOTHES DRYER. SOILED CLOTHING WAS STORED AGAINST FOOD ITEMS. FOOD WAS STORED ON THE DECK. AN OPEN BAG OF CEREAL WAS NOTED ON A SHELF.
Recommendation: 7.3.3.5.1 Food shall be protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 21
Site: Other-DRY STORES
Violation: THE SHELVING WAS NOT CONSTRUCTED OF EASY TO CLEAN MATERIALS.
Recommendation: 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Other-DRY STORES
Violation: A PORTION OF THE BULKHEAD WAS CONSTRUCTED OF PAINTED PARTICLE BOARD.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 36
Site: Other-DRY STORES
Violation: THE LIGHTING WAS INSUFFCIENT IN THIS AREA. THE LIGHT BULBS WERE NOT SHIELDED.
Recommendation: 7.7.5.1.2 The light intensity shall be at least 110 Lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning. 7.7.5.2.1 Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service, and single-use articles.
Item No.: 37
Site: Other-DRY STORES
Violation: EXCESS MOISTURE WAS NOTED DRIPPING OFF THE BULKHEADS. THIS ROOM IS ALSO THE LAUNDRY FACILITIES.
Recommendation: 7.7.6.1.2 Ventilation hood systems and devices shall operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
Item No.: 38
Site: Other-DRY STORES
Violation: UNUSED EQUIPMENT WAS STORED ON THE DECK.
Recommendation: 7.7.7.1.1 Only articles necessary for the food service operation shall be stored in food preparation, food storage, and warewashing areas.
Item No.: 30
Site: Other-BAR
Violation: A PAPER TOWEL DISPENSER WAS NOT PROVIDED. A "WASH HANDS OFTEN" SIGN WAS NOT POSTED OVER THE HANDWASH SINK.
Recommendation: 7.7.1.1.6 A handwashing facility shall include a sink, soap dispenser, single-use towels dispenser, and waste receptacle. 7.7.1.1.7 A sign stating "WASH HANDS OFTEN" in a language that the food employees understand shall be posted over handwashing sinks.
Item No.: 26
Site: Other-BAR
Violation: A HEAVY COATING OF MOLD WAS NOTED IN THE ICE/WATER CONTACT SURFACES OF THE MACHINE.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 08
Site: Other-BAR
Violation: THE CARBONATOR WAS NOT FITTED WITH A VENTED BACKFLOW PREVENTION DEVICE.
Recommendation: Install a vented backflow prevention device on the potable water line immediately prior to the carbonator.
Item No.: 21
Site: Other-BAR
Violation: A THERMOMETER WAS NOT PROVIDED IN THE SANYO REFRIGERATOR.
Recommendation: 7.4.2.4.9.2 Temperature measuring devices shall conform to the following guidelines: (2) Cold or hot holding equipment used for potentially hazardous food shall be designed to include and shall be equipped with at least one integral or affixed temperature measuring device that is located to allow easy viewing of the device's temperature display.
Item No.: 16
Site: Other-BAR
Violation: MILK WAS TESTED AT 57°F AND YOGURT WAS TESTED AT 54°F IN THE SANYO REFRIGERATOR. THERE WAS ONE CONTAINER OF MILK AND THREE OF YOGURT. THESE ITEMS WERE DISCARDED.
Recommendation: 7.3.5.3.1.1 Potentially hazardous food shall be maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above,; or (2) At 5°C (41°F) or less.
Item No.: 31
Site: Other-GALLEY
Violation: PLANT FOOD WAS STORED UNDER THE HANDWASH SINK WITH CLEANSERS.
Recommendation: 7.6.2.2.1 Only poisonous or toxic materials that are required for the operation and maintenance of a food areas of the vessel, such as for the cleaning and sanitizing of equipment and utensils and the control of insects and rodents, shall be allowed in the food areas of the vessel.
Item No.: 20
Site: Other-BAR
Violation: THE CUTTING BOARD WAS BADLY WORN.
Recommendation: 7.4.5.1.3 Surfaces such as cutting blocks and boards that are subject to scratching and scoring shall be resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
Item No.: 33
Site: Other-BAR
Violation: THE DECK WAS SOILED UNDER EQUIPMENT.
Recommendation: 7.7.4.2.1 Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
Item No.: 21
Site: Other-BAR
Violation: THE NON-FOOD CONTACT SURFACES WERE DIFFICULT TO CLEAN DUE TO GAPS BETWEEN EQUIPMENT.
Recommendation: 7.4.4.1.1 Equipment that is fixed because it is not easily movable shall be installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, under and above the equipment; (2) Spaced from adjoining equipment, bulkhead, and deckhead at a distance of not more than 1 millimeter or 1/32 inch; or (3) Sealed to adjoining equipment or bulkhead, if the equipment is exposed to spillage or seepage.
Item No.: 36
Site: Other-BAR
Violation: THE DECKHEAD MOUNTED LIGHT BULBS WERE NOT SHIELDED OR SHATTER-RESISTANT.
Recommendation: 7.7.5.2.1 Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service, and single-use articles.
Item No.: 10
Site: Other-WHIRLPOOL SPA
Violation: A PRECAUTIONS AND RISKS SIGN WAS NOT POSTED AT THE WHIRLPOOL SPA.
Recommendation: 6.4.1.1.3 A sign shall be installed near the whirlpool spas that lists standard safety precautions and risks, warning against use by particularly susceptible people, such as those who are immunocompromised.
Item No.: 19
Site: Other-BAR
Violation: A SNEEZE GUARD WAS NOT PROVIDED FOR FOODS ON DISPLAY AT THE BAR COUNTER.
Recommendation: 7.3.3.6.1 Food on display shall be protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
Item No.: 40
Site: Other-INTEGRATED PEST MANAGEMENT
Violation: THE VESSEL HAS NOT DEVELOPED AN INTEGRATED PEST MANAGEMENT PLAN.
Recommendation: 8.1.1.1.1 Each vessel shall develop an Integrated Pest Management Plan to address effective monitoring and control strategies for pests aboard the vessel. 8.1.1.1.2 The Integrated Pest Management Plan shall set a schedule for periodic monitoring inspections including some at night. 8.1.1.1.3 The Integrated Pest Management Plan shall include provisions for active monitoring including pest sighting logs for the operational areas of the vessel and training for crew members in charge of log completion. 8.1.1.1.4 The Integrated Pest Management Plan shall include passive surveillance procedures such as glue traps and other monitoring tools, as well as location of each. A monitoring log on passive surveillance procedures shall be maintained. 8.1.2.1.1 The Integrated Pest Management Plan shall include a record of pesticides used and their effectiveness. 8.1.2.1.3 The training of the pest-control personnel shall be documented in the Integrated Pest Management Plan. 8.1.2.1.4 The Integrated Pest Management Plan shall establish health and safety procedures to protect the passengers and crew.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT INSTRUCTIONS
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SAFARI QUEST - CAS - [08/10/2002] .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory