Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seadream I Cruise Line: Sea Dream Yacht Club Inspection Date: 11/23/2003 Inspection Score: 87
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Other-GALLEY COFFEE STATION
Violation: THE BACKFLOW PREVENTION DEVICE ON THE COFFEE MACHINE'S WATER LINE WAS NOT VENTED. THIS WAS CORRECTED DURING THE SURVEY.
Recommendation: 5.7.1.2.1 Backflow preventers shall be installed when air gaps are impractical or when water under pressure is required.
Item No.: 20
Site: Other-FOOD SERVICE GENERAL
Violation: THE FOOD CONTACT SURFACES OF OLDER EQUIPMENT SUCH AS REFRIGERATORS HAD EXPOSED WIRING, COOLING COILS AND OTHER DIFFICULT TO CLEAN AREAS. THIS IS A REPEAT VIOLATION.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition. 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 21
Site: Other-FOOD SERVICE GENERAL
Violation: THE NON FOOD CONTACT SURFACES OF OLDER EQUIPMENT HAD DIFFICULT TO CLEAN FEATURES SUCH AS GAPS AND CREVICES. THIS IS A REPEAT VIOLATION.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 33
Site: Other-FOOD SERVICE GENERAL
Violation: THE DECKS, BULKHEADS AND DECKHEADS HAD GAPS AND OPEN SEAMS, EXPOSED WIRING AND PIPING MAKING THE AREAS DIFFICULT TO CLEAN. THIS IS A REPEAT VIOLATION.
Recommendation: 7.7.4.1.8 Surfaces subject to routine splashes, spillage or other soiling during normal use shall have easily cleanable features.
Item No.: 26
Site: Other-FOOD SERVICE GENERAL
Violation: PREVIOUSLY CLEANED AND STORED AS CLEAN FRYER COILS WERE SOILED WITH CARBONIZED GREASE RESIDUE.
Recommendation: 7.5.5.1.2 The food-contact surfaces of cooking equipment and pans shall be kept free of encrusted grease deposits and other soil accumulations.
Item No.: 33
Site: Other-MAIN GALLEY & GALLEY # 5
Violation: THE INTERIOR OF THE VENTILATION HOODS WERE SOILED WITH A GREASY RESIDUE.
Recommendation: 7.7.4.2.1 Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
Item No.: 26
Site: Other-DISHWASH CLEAN AREA
Violation: FOUR PREVIOUSLY CLEANED AND STORED AS CLEAN SHEET PANS WERE SOILED WITH DRIED FOOD DEBRIS.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 22
Site: Other-DISHWASH
Violation: THE FINAL RINSE TEMPERATURE GAUGE WAS MORE THAN 20° OUT OF CALIBRATION. THE DISH TEMPERATURE WAS 178° F AND THE FINAL RINSE TEMPERATURE GAUGE READ 210°F.
Recommendation: 7.5.4.1.1 Warewashing equipment shall be maintained in good repair and proper adjustment including: (1) Warewashing equipment shall be maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines. (2) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
Item No.: 20
Site: Other-BAKERY
Violation: THE FLOOR MIXER COLLAR WAS SEALED TO THE MIXER, MAKING IT DIFFICULT TO CLEAN.
Recommendation: 7.4.2.2.2 CIP equipment shall meet the following criteria: (1) It shall be designed and constructed so that cleaning and sanitizing solutions circulate throughout a fixed system and contact all interior food-contact surfaces, and the system is self-draining or capable of being completely drained of cleaning and sanitizing solutions; or (2) CIP equipment that is not designed to be disassembled for cleaning shall be designed with inspection access points to ensure that all interior food-contact surfaces throughout the fixed system are being effectively cleaned.
Item No.: 38
Site: Other-BAKERY
Violation: THE EQUIPMENT USED TO MAKE SHERBET WAS OUT OF ORDER AND WAS NO LONGER NEEDED.
Recommendation: 7.7.7.1.1 Only articles necessary for the food service operation shall be stored in food preparation, food storage, and warewashing areas.
Item No.: 16
Site: Other-COLD GALLEY STORAGE
Violation: THE INTERNAL TEMPERATURE OF ONE TRAY OF GROUND BEEF PATTIES WAS MEASURED WITH A DIAL STEM THERMOMETER AND REGISTERED A TEMPERATURE OF 48 °F AT 10:15 AM. THE GROUND BEEF PATTIES WERE PREPARED AT 2 AM. THIS TRAY WAS STORED ON THE BOTTOM SHELF OF THE REACH IN REFRIGERATION UNIT.
Recommendation: 7.3.5.3.1.1 Potentially hazardous food shall be maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above,; or (2) At 5°C (41°F) or less.
Item No.: 26
Site: Other-MEAT PREPARATION AREA
Violation: THE COUNTER MIXER COLLAR AND FOOD SPLASH AREAS WERE SOILED WITH DRIED FOOD DEBRIS.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 19
Site: Other-MEAT PREPARATION AREA
Violation: THE "FLY ZAPPER" ELECTROCUTION DEVICE WAS LOCATED ABOVE THE MEAT SAW.
Recommendation: 8.2.2.2.2 The insect devices shall not be located over food storage, preparation, and service areas. Dead insects and insect fragments shall be prevented from being impelled onto or falling on exposed food.
Item No.: 26
Site: Other-MEAT PREPARATION AREA
Violation: THE MEAT GRINDER ATTACHMENT WAS SOILED WITH EXCESSIVE DRIED MEAT RESIDUE.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 32
Site: Other-SOLID WASTE CONTAINERS
Violation: NUMEROUS OPEN REFUGE BAGS WERE STORED ON THE BACK DECK, ALONG WITH WET CARDBOARD BOXES AND BROKEN WINE BOTTLES. NUMEROUS FLIES WERE OBSERVED IN THIS AREA. PROVISIONS WERE BEING LOADED OVER, ON TOP OF AND AROUND THIS REFUSE. BOXES OF FOOD AND OR CHEMICALS WERE SITTING ON TOP OF, BESIDE OR AMONG ONE ANOTHER AND THE BAGS OF REFUSE. A COVERED CONTAINER WAS NOT AVAILABLE FOR REFUSE STORAGE.
Recommendation: 7.7.2.1.4 A receptacle or waste-handling container shall be provided in each area of the vessel or premise where refuse is generated or commonly discarded or where recyclables are placed. 7.7.2.2.3 The garbage and refuse storage room shall be located so as to prevent contamination in food preparation, storage, and utensil washing areas. 7.7.2.2.4 The garbage and refuse storage room shall be maintained in good repair and kept clean.
Item No.: 15
Site: Other-DAIRY REFRIGERATION UNIT
Violation: NUMEROUS CASES OF NON GRADE A MILK AND HALF AND HALF DAIRY PRODUCTS WERE OBSERVED IN THE DAIRY COOLER ("ST. THOMAS DAIRY"). THE CHEF WAS INFORMED THAT THIS PRODUCT SHOULD NOT BE SERVED AND RETURNED TO THE VENDOR.
Recommendation: 7.3.2.2.4 Eggs and milk products shall be received as follows: (1) Liquid, frozen, and dry eggs and egg products shall be obtained pasteurized. (2) Fluid and dry milk and milk products complying with Grade A standards as specified in law shall be obtained pasteurized. (3) Frozen milk products, such as ice cream, shall be obtained pasteurized as specified in 21 CFR 135 Frozen Desserts. (4) Cheese shall be obtained pasteurized unless alternative procedures to pasteurization are specified in the CFR, such as 21 CFR 133 Cheeses and Related Cheese Products, for curing certain cheese varieties.
Item No.: 19
Site: Other-CREW MESS
Violation: THE SALAD BAR FOOD GUARD DID NOT EXTEND FAR ENOUGH ON THE END TO PROTECT THE FOOD STORED BELOW.
Recommendation: 7.3.3.6.1 Food on display shall be protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
Item No.: 26
Site: Other-PANTRY 3
Violation: ONE PREVIOUSLY CLEANED AND STORED AS CLEAN SOILED GLASS WAS OBSERVED IN THE CLEAN DISH RACK.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE HALOGENATION ANALYZER CHART RECORDER WAS NOT CALIBRATED BEFORE USE BEFORE BUNKERING AND/OR PRODUCTION OF POTABLE WATER.
Recommendation: 5.5.2.2.1 Halogen analyzer-chart recorder charts shall be changed, initialed, and dated daily. Charts shall contain notations of any unusual water events in the potable water system.
Item No.: 08
Site: Other-POTABLE WATER
Violation: SEVERAL OF THE SHOWER BACKFLOW PREVENTION DEVICES WERE NOT VENTED.
Recommendation: 5.7.1.2.1 Backflow preventers shall be installed when air gaps are impractical or when water under pressure is required.
Item No.: 40
Site: Other-INTEGRATED PEST MANAGEMENT
Violation: NIGHT TIME INSPECTIONS WERE NOT BEING DOCUMENTED IN THE ACTIVE SURVEILLANCE LOG.
Recommendation: 8.1.1.1.2 The Integrated Pest Management Plan shall set a schedule for periodic monitoring inspections including some at night.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE VESSEL HAD TWO REDUCED PRESSURE ASSEMBLIES BOLTED TO A LEDGE BELOW THE INTERNATIONAL SHORE CONNECTION PIPE LINE. STAFF STATED THAT THE DEVICES WERE TESTED ANNUALLY BUT NOT INSTALLED IN LINE.
Recommendation: 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 07
Site: Other-POTABLE WATER TANKS
Violation: THE VESSEL HAS APPLIED FOR A VARIANCE TO USE SKIN TANKS. CONDUCTIVITY METERS HAVE BEEN INSTALLED IN EACH TANK.
Recommendation: 5.3.1.1.1 Potable water tanks shall not share a common wall with the hull of the vessel or with tanks containing non-potable water or other liquids.
Item No.: 41
Site: Other-VENTILATION
Violation: THE VENTILATION CONDENSATE COLLECTION PANS WERE NOT VISIBLE WITHOUT DISASSEMBLING THE UNIT. THIS MAKES THE CLEANING OF THE UNIT DIFFICULT.
Recommendation: 9.2.1.1.1 Air handling unit condensate drain pans and collection systems shall be accessible for inspection, maintenance, and cleaning.
Item No.: *
Site: Other-COMMENT
Violation: THE VESSEL WAS VERY CLEAN AND WELL ORGANIZED WITH A FEW EXCEPTIONS. THE POTABLE WATER AND POOL RECORDS WERE EXCELLENT. NUMEROUS AREAS WERE DIFFICULT TO CLEAN DUE TO THE AGE OF THE VESSEL AND EQUIPMENT. THE STAFF SHOULD BE COMMENDED FOR THE JOB THEY DO WITH THE EQUIPMENT THEY HAVE.
Recommendation:
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: -SEA DREAM 1 - CAS - [INSPECTION DATE 11/23/2003] .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program