Cruise Ship: Island Princess Cruise Line: Princess Cruises Inspection Date: 12/16/2003 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: ISLAND PRINCESS - CAS - 12/16/2003.
Recommendation:
Item No.: *
Site: Other-RECORD KEEPING
Violation: THE LOGS AND RECORD KEEPING FOR THE POTABLE WATER, AND POOLS AND SPAS WERE EXCELLENT.
Recommendation:
Item No.: 08
Site: Other-BARS GENERAL
Violation: THE INTERMEDIATE ATMOSPHERIC VENTS ON NUMEROUS CARBONATION UNIT BACKFLOW PREVENTERS HAD PLASTIC PLUGS INSTALLED PREVENTING THEM FROM OPERATING AS DESIGNED.
Recommendation: Remove the plastic plugs.
Item No.: 21
Site: Other-HORIZON GRILL - BUFFET LINE
Violation: LOOSE AND PEELING SEALANT WAS NOTED WITHIN THE EXHAUST HOODS OVER THE PORT AND STARBOARD OMELET STATIONS.
Recommendation: Remove the peeling sealant in these areas. If the seams between the stainless steel panels are less than 1 mm there is no requirement to seal them with sealant. If greater than 1 mm it is recommended that they be covered by a stainless steel profile.
Item No.: 21
Site: Other-MAIN GALLEY DECK 5 / BUTCHER SHOP
Violation: THE ECOLAB FLEX PAK DISH DETERGENT HOLDER HAD DAMAGED PLASTICIZED SUPPORTS THAT WERE CORRODING. THE UNIT WAS LESS THAN 30 DAYS OLD.
Recommendation: Provide a detergent holder that meets the same requirements as all other galley equipment. 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 34
Site: Other-PROVISIONS / VEGETABLE FREEZER
Violation: THE CONDENSATE DRAIN LINE FROM THE CONDENSER UNIT ADJACENT TO THE DOOR WAS LEAKING. A PLASTIC CONTAINER WAS POSITIONED ON THE DECK UNDER THE UNIT TO COLLECT THE LEAKING CONDENSATE.
Recommendation: Repair the leaking drain line.
Item No.: 37
Site: Other-MAIN GALLEY DECK 5 / POT WASH AREA
Violation: CONDENSATION WAS NOTED DRIPPING FROM THE INSIDE OF THE EXHAUST HOOD OVER THE POTWASHING MACHINE AND ONTO THE CLEAN LANDING.
Recommendation: Ensure that the exhaust hood extraction is properly balanced to remove the steam coming from the pot wash machine, allow the complete draining of the potwash machine before opening the doors to remove the pots and pans.