Item No.:
21
|
|
Site:
Other-MAIN GALLEY-SOUP STATION
|
|
Violation:
A LOOSE GASKET WAS NOTED AT THE BOTTOM OF THE LEFT TILT KETTLE.
|
|
Recommendation:
7.4.1.1.9
Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
33
|
|
Site:
Other-MAIN GALLEY-SOUP STATION
|
|
Violation:
A GAP WAS NOTED BETWEEN THE BULKHEAD AND THE CONTROL BOX FOR THE LEFT TILT KETTLE.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY-PASTRY
|
|
Violation:
THE FINISH WAS WORN AND PEELING ON THE STACK OVEN DOOR HANDLES.
|
|
Recommendation:
7.4.2.1.2
Nonfood-contact surfaces of equipment and utensils shall be designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
|
|
|
Item No.:
27
|
|
Site:
Other-MAIN GALLEY-PASTRY
|
|
Violation:
THE REFRIGERATOR DRIP PANS WERE SOILED.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY DISHWASH
|
|
Violation:
A LONG CURTAIN WAS NOTED BETWEEN THE RINSE AND FINAL RINSE COMPARTMENTS. A LABEL STATING "SHORT CURTAIN" WAS POSTED ON THE MACHINE AT THIS LOCATION.
THE ARM JUST PRIOR TO THE FINAL RINSE ARM IN THE DISHWASH UNIT (107) WAS NOT SPRAYING. AS PER THE ENGINEER THIS WAS A RINSE ARM.
THE FINAL RINSE SPRAY IN THE GLASSWASH UNIT WAS NOT ACTIVATED UNTIL THE RACK WAS HALF-WAY THROUGH THE COMPARTMENT.
|
|
Recommendation:
Ensure that the curtains are placed in the unit in accordance with the manufacturer's recommendations.
7.5.4.1.1
Warewashing equipment shall be maintained in good repair and proper adjustment including:
(1) Warewashing equipment shall be maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines. (2) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
|
|
|
Item No.:
16
|
|
Site:
Other-MAIN GALLEY-SALAD PANTRY
|
|
Violation:
CANTALOUPE WAS TESTED AT 46°F IN THE WALK-IN UNIT. PLASTIC PANS OF CANTALOUPE WERE STACKED ON TOP OF EACH OTHER IMPEDING AIR CIRCULATION. PORTIONS OF THE CANTALOUPE IN THIS PAN WERE BELOW 41°F. THE CANTALOUPE WAS CHOPPED DURING THE NIGHT SHIFT WHICH ENDED AT 6:30 A.M. THE COOLING OF THIS PRODUCT WAS NOT ADEQUATELY MONITORED.
|
|
Recommendation:
7.3.5.2.2
Potentially hazardous food shall be cooled within 4 hours to 5°C (41°F) or less, if prepared from ingredients at ambient temperature, such as reconstituted foods and canned tuna.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY-SALAD PANTRY
|
|
Violation:
THE INSIDE SURFACE OF THE MANHART CHOPPER LID WAS SLIGHTLY SOILED WITH FOOD RESIDUE.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
20
|
|
Site:
Other-MAIN GALLEY-PREPARATION AREA
|
|
Violation:
THE INSIDE SURFACE OF THE BUFFALO CHOPPER LID WAS PITTED MAKING IT DIFFICULT TO CLEAN.
|
|
Recommendation:
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
33
|
|
Site:
Other-MAIN GALLEY-PORT ELEVATOR
|
|
Violation:
THE DOOR TRACK WAS SOILED AT THE RIGHT ELEVATOR.
|
|
Recommendation:
7.7.4.2.1
Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
|
|
|
Item No.:
21
|
|
Site:
Other-DECK 2 & 3 DINING ROOM
|
|
Violation:
GAPS WERE NOTED AROUND THE FSS COUNTERS AND BOSE SPEAKER COUNTERS NEAR THE DECK. THESE WERE MIXED USE COUNTERS.
|
|
Recommendation:
7.4.2.2.6
Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
33
|
|
Site:
Other-DECK 2 & 3 DINING ROOMS
|
|
Violation:
THE DECK WAS SOILED BEHIND THE FSS AND BOSE COUNTERS WHERE GAPS WERE NOTED BETWEEN THE COUNTERS AND THE DECKS.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
|
|
|
Item No.:
26
|
|
Site:
Other-DECK 2 WINE CELLAR
|
|
Violation:
SEVERAL GLASSES WERE SOILED AND STORED AS CLEAN.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Other-DECK 3 DINING ROOM PANTRY
|
|
Violation:
FOOD RESIDUE WAS NOTED IN THE BOTTOM COMPARTMENT OF THE WARMER DRAWERS.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Other-CREW GALLEY
|
|
Violation:
THE LABELS WERE PEELING OFF THE FRONT OF THE GROOVED GRILL MAKING THIS AREA DIFFICULT TO CLEAN. THIS WAS CORRECTED DURING THE INSPECTION.
|
|
Recommendation:
7.4.1.1.9
Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
36
|
|
Site:
Other-CREW MESS
|
|
Violation:
THE COATING WAS WORN ON SEVERAL SHATTER-RESISTANT BULBS IN THE HOT STATION.
|
|
Recommendation:
7.7.5.2.1
Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service, and single-use articles.
|
|
|
Item No.:
28
|
|
Site:
Other-CREW MESS
|
|
Violation:
THE PLATES WERE NOT STORED COVERED OR INVERTED ON THE SERVICE LINE.
|
|
Recommendation:
7.5.7.3.2
Clean equipment and utensils shall be stored:
(1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
36
|
|
Site:
Other-PETTY OFFICERS MESS
|
|
Violation:
ONE BULB IN THE HOT STATION WAS NOT SHATTER-RESISTANT.
|
|
Recommendation:
7.7.5.2.1
Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service, and single-use articles.
|
|
|
Item No.:
26
|
|
Site:
Other-PETTY OFFICERS MESS
|
|
Violation:
MILK RESIDUE WAS NOTED IN THE MILK DISPENSING TUBE FOR THE COFFEE MACHINE. THIS TUBE WAS SOAKING IN A PAN OF WATER THAT WAS SAID TO HAVE A DETERGENT IN IT.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch. At a minimum the tube and fittings must be washed, rinsed, and sanitized every 4 hours given the fact that time is used as a control for the milk.
|
|
|
Item No.:
36
|
|
Site:
Other-OFFICERS MESS
|
|
Violation:
TWO BULBS WERE NOT SHATTER-RESISTANT IN THE HOT STATION.
|
|
Recommendation:
7.7.5.2.1
Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service, and single-use articles.
|
|
|
Item No.:
20
|
|
Site:
Other-PETTY OFFICERS AND OFFICERS MESS
|
|
Violation:
THE UNDERCOUNTER REFRIGERATION UNIT THERMOMETERS NOTED 50°F IN BOTH OF THESE MESS ROOMS. THE REFRIGERATION UNITS WERE EMPTY AT THE TIME OF THE INSPECTION.
|
|
Recommendation:
7.4.3.1.1
Equipment for cooling and heating food, and holding cold and hot food, shall be sufficient in number and capacity to maintain specified potentially hazardous food temperatures.
|
|
|
Item No.:
26
|
|
Site:
Other-CREW POTWASH
|
|
Violation:
TWO CONE STRAINERS THAT WERE STORED AS CLEAN WERE SLIGHTLY SOILED WITH FOOD RESIDUE.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
28
|
|
Site:
Other-STAFF MESS
|
|
Violation:
THE PLATES AND BOWLS WERE NOT STORED COVERED OR INVERTED ON THE SERVICE LINE.
|
|
Recommendation:
7.5.7.3.2
Clean equipment and utensils shall be stored:
(1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
20
|
|
Site:
Other-PROVISIONS-VEGETABLE PREPARATION
|
|
Violation:
THE COVERS OF THE POTATO PEELERS WERE CRACKED MAKING THEM DIFFICULT TO CLEAN.
|
|
Recommendation:
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
33
|
|
Site:
Other-CANOPY BAR STARBOARD
|
|
Violation:
THE DECK AROUND THE SLIDING DOOR WAS SOILED. THIS AREA WAS DIFFICULT TO CLEAN DUE TO LIMITED ACCESS.
|
|
Recommendation:
7.7.4.2.1
Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
|
|
|
Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: CARNIVAL SPIRIT - CAS - [02/11/2004] .
|
|
Recommendation:
|
|
|
Item No.:
24
|
|
Site:
Other-LIDO GALLEY
|
|
Violation:
THE PANS PLACED IN THE SANITIZE SINK IN THE POTWASH WERE NESTED, SO THAT THE FOOD-CONTACT SURFACES OF SOME OF THE PANS WERE NOT IN FULL CONTACT WITH THE WATER.
|
|
Recommendation:
Ensure that the pans are not nested in the final rinse compartment.
|
|
|
Item No.:
37
|
|
Site:
Other-LIDO GALLEY
|
|
Violation:
HEAVY CONDENSATE WAS NOTED ON A VENT ABOVE THE SANITIZE SINK IN THE POTWASH AREA.
|
|
Recommendation:
7.7.6.1.2
Ventilation hood systems and devices shall operate effectively to prevent grease and condensate from collecting on the bulkheads and deckheads and remove contaminants generated by equipment located under them.
|
|
|
Item No.:
25
|
|
Site:
Other-LIDO GALLEY
|
|
Violation:
A WET WIPING CLOTH WAS NOTED IN AN EMPTY BUCKET IN THE POTWASH AREA.
|
|
Recommendation:
7.3.3.4.4.4
Wiping cloths shall be restricted to the following:
(4) Wet wiping cloths used with a freshly made sanitizing solution and dry wiping cloths shall be free of food debris and visible soil.
|
|
|
Item No.:
26
|
|
Site:
Other-LIDO BUFFET
|
|
Violation:
ONE SOILED SPOON WAS NOTED IN AN UNDERCOUNTER CABINET IN THE TASTE OF NATIONS SERVICE AREA.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
28
|
|
Site:
Other-LIDO BUFFET
|
|
Violation:
BOWLS ON THE BUFFET LINE WERE NOT STORED COVERED OR INVERTED. THE BUFFET WAS CLOSED AT THE TIME OF THE INSPECTION.
|
|
Recommendation:
7.5.7.3.2
Clean equipment and utensils shall be stored:
(1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
36
|
|
Site:
Other-LIDO BUFFET GENERAL
|
|
Violation:
MOST OF THE LIGHTS OVER THE COUNTERS AND SERVICE AREAS WERE NOT SHIELDED OR SHATTER-RESISTANT.
|
|
Recommendation:
7.7.5.2.1
Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service, and single-use articles.
|
|
|
Item No.:
10
|
|
Site:
Other-POOLS
|
|
Violation:
A SHEPHERD'S HOOK WAS NOT PROVIDED AT THE MIDDLE POOL. THIS WAS CORRECTED DURING THE INSPECTION.
|
|
Recommendation:
6.4.1.2.1
Easy access shepherd's hook and approved floatation device shall be provided at a prominent location near each public swimming pool.
|
|
|
Item No.:
05
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
THE HALOGEN ANALYZER ON DECK 8 NOTED 0.78 PPM WHILE A MANUAL TEST NOTED 0.28 PPM. THE ENGINEER'S TEST NOTED 0.66 PPM. LATER DURING THE INSPECTION THE HALOGEN ANALYZER ON DECK 8 NOTED 0.74 PPM WHILE A MANUAL TEST NOTED 0.27 PPM.
THE HALOGEN ANALYZER ON DECK 9 NOTED 0.61 PPM WHILE A MANUAL TEST NOTED 0.25 PPM.
THREE OF THE VESSEL'S CHLORINE TEST KITS WERE CHECKED USING THE MANUFACTURER'S SECONDARY STANDARDS KIT AND WERE FOUND TO BE BEYOND THE TOLERANCE ALLOWED FOR EACH STANDARD.
|
|
Recommendation:
5.5.1.2.3
The free residual halogen measured by the halogen analyzer shall be ±0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
|
|
|
Item No.:
06
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
THE HALOGEN ANALYZER-CHART RECORDER CHARTS HAD A RANGE OF 0-50 PPM FOR NUMEROUS DAYS.
|
|
Recommendation:
5.5.2.1.1
Halogen analyzer-chart recorder charts shall have a range of 0.0 to 5.0 mg/L (ppm) and have a recording period of 24 hours.
|
|
|
Item No.:
41
|
|
Site:
Other-VENTILATION
|
|
Violation:
THE CONDENSATE DRAIN PANS AND COLLECTION SYSTEMS IN ALL OF THE AIR HANDLING UNITS WERE NOT ACCESSIBLE FOR INSPECTION, MAINTENANCE, AND CLEANING.
|
|
Recommendation:
9.2.1.1.1
Air handling unit condensate drain pans and collection systems shall be accessible for inspection, maintenance, and cleaning.
|
|