Cruise Ship: The World Cruise Line: ResidenSea Inspection Date: 02/24/2004 Inspection Score: 92
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE POTABLE WATER HOSES WERE NOT STORED WITH THE ENDS CAPPED OR COUPLED TOGETHER.
Recommendation: 5.3.3.2.5 Potable water hoses shall be stowed with the ends capped, on reels, or racks in potable water hose lockers.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE PORT WATER WAS NOT CONSISTENTLY TESTED FOR PH AND CHLORINE DEMAND PRIOR TO THE START OF BUNKERING WHEN THE VESSEL WAS IN PORT FOR MULTIPLE DAYS.
Recommendation: 5.2.1.2.1 A halogen demand test and pH shall be conducted on the shore-side water supply before starting the bunkering process to establish the correct halogen dosage.
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE CALIBRATION OF THE ANALYZER RECORDER FOR PRODUCTION AND BUNKERING WAS NOT CONDUCTED AT THE START OF BUNKERING AND PRODUCTION BUT RATHER AT A CERTAIN TIME DURING THE DAY.
Recommendation: 5.2.1.2.4 Halogen analyzer-chart recorders used in lieu of manual tests and logs shall be calibrated at the beginning of bunkering or production, and the calibration shall be recorded on the chart or in a log book.
Item No.: 07
Site: Other-POTABLE WATER
Violation: THE DISINFECTION OF THE POTABLE WATER TANKS WAS ACCOMPLISHED BY USING A 10 PPM SOLUTION FOR 24 HOURS.
Recommendation: 5.3.4.1.4 Disinfection following potential contamination shall be accomplished by increasing free residual halogen to at least 50 mg/L (ppm) throughout the affected area and maintaining this concentration for 4 hours.
Item No.: 08
Site: Other-POTABLE WATER
Violation: A COMPREHENSIVE CROSS-CONNECTION CONTROL PROGRAM ADDRESSING ALL CONNECTIONS TO THE POTABLE WATER SYSTEM HAS NOT BEEN DEVELOPED FOR THIS VESSEL.
Recommendation: 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 05
Site: Other-POTABLE WATER
Violation: THE FAR POINT ANALYZER CHART-RECORDER NOTED 2.14 WHILE A MANUAL TEST NOTED 0.99. A SECOND TEST NOTED 1.00 PPM WHILE THE ANALYZER CHART-RECORDER NOTED 2.21 PPM. THE ENGINEER'S TESTS NOTED 2.11 PPM AND 2.17 PPM, RESPECTIVELY. AS PER TECHNICAL SUPPORT AT HACH THE ENGINEER'S TEST KIT WAS NOT USED PROPERLY AND THE TEST SAMPLE SHOULD HAVE BEEN DILUTED IN ACCORDANCE WITH THE TEST KIT'S MANUAL INSTRUCTIONS.
Recommendation: 5.5.1.2.3 The free residual halogen measured by the halogen analyzer shall be ±0.2 mg/L (ppm) of the free residual halogen measured by the manual test. Ensure that the test kit is used in accordance with the manufacturer's instructions.
Item No.: 09
Site: Other-DECK 11 POOL
Violation: THE POOL WATER WAS TESTED AT 0.84 AND 0.79 PPM FREE CHLORINE.
Recommendation: 6.2.2.1.1 A free residual halogen of >1.0 and <3.0 mg/L (ppm) shall be maintained in recirculated swimming pools.
Item No.: 09
Site: Other-DECK 11 WHIRLPOOL SPA
Violation: THE WHIRLPOOL SPA WATER WAS TESTED AT 1.71 PPM FREE CHLORINE.
Recommendation: 6.3.2.1.1 Whirlpool spas shall maintain a free residual chlorine of >3.0 mg/L (ppm) and <10 mg/L (ppm), or a free residual bromine of >4.0 mg/L (ppm) and <10 mg/L (ppm).
Item No.: 09
Site: Other-DECK 5 WHIRLPOOL SPA
Violation: THE WHIRLPOOL SPA WATER WAS TESTED AT 1.44 PPM FREE CHLORINE.
Recommendation: 6.3.2.1.1 Whirlpool spas shall maintain a free residual chlorine of >3.0 mg/L (ppm) and <10 mg/L (ppm), or a free residual bromine of >4.0 mg/L (ppm) and <10 mg/L (ppm).
Item No.: 41
Site: Other-VENTILATION
Violation: ALTHOUGH THE DRAIN PAN WAS CLEAN IN AC-Z 1.11 THE VESSEL DOES NOT HAVE A PROCEDURE OR PLAN FOR CLEANING AIR CONDITIONING UNITS.
Recommendation: 9.2.1.2.2 Evaporative condensers shall be inspected at least annually and cleaned as necessary to remove scale and sediment. Cooling coils and condensate pans shall be cleaned as necessary to remove dirt and organic material. 9.2.1.2.3 Vessels shall have a plan to inspect and maintain heating, ventilation, and air conditioning systems in accordance with manufactures recommendations and industry standards.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE POTABLE WATER LINES SUPPLYING SINKS WERE NOT STRIPED BLUE IN AC ROOM 16 AND IN THE ENGINE ROOM AC ROOM.
Recommendation: 5.3.2.1.1 Potable water piping shall be painted light blue or striped with 15 cm (6 inches) light blue bands or a light blue stripe at fittings on each side of partitions, decks, and bulkheads and at intervals not to exceed 5 m (15 feet) in all spaces, except where the decor would be marred by such markings.
Item No.: 37
Site: Other-TIDES DISHWASH/GLASSWASH AREA
Violation: CONDENSATE WAS NOTED ON THE DECKHEAD AT THE SOILED END AND SOILED DROP-OFF NEAR THE DISHWASH UNIT.
Recommendation: 7.4.3.2.1 Ventilation hood systems and devices shall be sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 20
Site: Other-EAST GALLEY
Violation: SLOTTED FASTENERS WERE NOTED ON THE FRYER COILS.
Recommendation: 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: THE WORLD - CAS - [02/24/2004] .
Recommendation:
Item No.: 27
Site: Other-REGATTA PANTRY
Violation: A PINK SLIME MOLD WAS NOTED ON THE SEALANT BETWEEN THE UPPER COMPARTMENT AND THE ICE BIN OF THE MANITOWOC ICE MACHINE. THIS WAS NOTED ON THE NON-FOOD CONTACT SURFACES OF THE UNIT
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 29
Site: Other-REGATTA PANTRY
Violation: A SMALL PLASTIC CONTAINER OF SANITIZER SOLUTION WAS PARTIALLY BLOCKING THE HANDWASH SINK.
Recommendation: 7.7.1.3.1 Handwashing facilities shall be used for no other purpose and shall be accessible at all times.
Item No.: 22
Site: Other-MARINA GALLEY - DISHWASH
Violation: AN ERRATIC SPRAY PATTERN WAS NOTED AT THE FINAL RINSE SPRAY ARM.
Recommendation: Clean out the nozzles of the final rinse in the upper spray arm.
Item No.: 22
Site: Other-TIDES GALLEY - DISHWASH MACHINE
Violation: AN ERRATIC SPRAY PATTERN WAS NOTED AT THE FINAL RINSE SPRAY ARM. TWO OF THE BOTTOM FINAL RINSE NOZZLES WERE CLOGGED.
Recommendation: Clean out the nozzles for the upper and lower final rinse spray arms.