Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seadream I Cruise Line: Sea Dream Yacht Club Inspection Date: 12/16/2001 Inspection Score: 90
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 27
Site: Other-OUTDOOR CAFÉ
Violation: FOOD RESIDUE AND OTHER SOIL WAS NOTED IN DIFFICULT TO CLEAN AREAS TO THE RIGHT OF PREP STATION, SEAMS BETWEEN MICROWAVE AND ITS MOUNTING BRACKE,T ABOVE GRILL STATION, AND ALSO UNDER AND AROUND THE TOASTER STATION. (SEE GENERAL COMMENTS ABOUT CONSTRUCTION OF NON-FOOD CONTACT AREAS.)
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 26
Site: Other-OUTDOOR CAFÉ
Violation: A SMALL AMOUNT OF FOOD SOIL WAS FOUND ON SEVERAL SERVICE UTENSILS IN THE CLEAN STORAGE AREA.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 07
Site: Other-POTABLE WATER SYSTEM
Violation: TWO FORWARD POTABLE WATER TANKS HAVE A COMMON BULKHEAD WITH THE HULL OF THE SHIP. A SALINITY METER IS IN USE TO DETERMINE IF SEAWATER SEEPS INTO POTABLE WATER. CALIBRATIONS ARE DONE ON THE UNIT, BUT NOT RECORDED. VERIFY VARIANCE HAS BEEN SUBMITTED OUTLINING THESE PROCEDURES AND MAINTAIN A COPY OF THE VARIANCE ON THE SHIP.
Recommendation: 5.3.1.1.1 Potable water tanks shall not share a common wall with the hull of the vessel or with tanks containing non-potable water or other liquids.
Item No.: 03
Site: Other-POTABLE WATER SYSTEM
Violation: CARE SHOULD BE TAKEN ABOUT OPERATING THE SHIP'S REVERSE OSMOSIS PLANT AND EVAPORATORS CLOSE TO SHORE WITH GIVEN ITINERARIES. AVOID PRODUCTION IN HARBORS AND OTHER POLLUTED AREAS.
Recommendation: 5.1.2.1.1 A distillation plant or other process that supplies water to the vessel's potable water system shall not operate in polluted or harbor areas.
Item No.: 41
Site: Other-FAN ROOMS
Violation: THE UPPER DECK FAN ROOM CONDENSATION PAN HAD A BUILD-UP OF ORGANIC MATERIAL ON THE SURFACE..
Recommendation: 9.2.1.2.1 Air handling units shall be kept clean.
Item No.: 08
Site: Other-POTABLE WATER SYSTEM
Violation: THE INTERNATIONAL SHORE CONNECTION FOR THE FIRE SYSTEM WAS NOT PROTECTED WITH A REDUCED PRESSURE ASSEMBLY BACKFLOW PREVENTER.
Recommendation: Install the appropriate reduced pressure backflow preventer for the fire system.
Item No.: 20
Site: Other-FOOD SERVICE GENERAL
Violation: FOOD CONTACT AND SPLASH SURFACES OF EQUIPMENT SUCH AS REACH-IN COOLERS AND COOKING EQUIPMENT HAD DIFFICULT TO CLEAN FEATURES.
Recommendation: 7.4.5.1.1.1 Food-contact equipment shall be maintained in good repair and proper adjustment including: (1) Equipment shall be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 21
Site: Other-FOOD SERVICE GENERAL
Violation: MOUNTING OF FOOD SERVICE EQUIPMENT DID NOT PROVIDE ADEQUATE CLEANING AREAS AROUND THEM. SOME FOOD EQUIPMENT HAD DIFFICULT TO CLEAN GAPS AND SEAMS AROUND THEM.
Recommendation: 7.4.4.1.1 Equipment that is fixed because it is not easily movable shall be installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, under and above the equipment; (2) Spaced from adjoining equipment, bulkhead, and deckhead at a distance of not more than 1 millimeter or 1/32 inch; or (3) Sealed to adjoining equipment or bulkhead, if the equipment is exposed to spillage or seepage. 7.4.5.1.2 Nonfood-contact equipment shall be maintained in good repair and proper adjustment including: (1) Equipment shall be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 33
Site: Other-FOOD SERVICE GENERAL
Violation: DRAIN LINES, SUPPORT BRACKETS, ADJACENT CABLING, WIRING AND PLUMBING MOUNTED ON BULKHEADS AND DECKS MADE FOOD AREAS DIFFICULT TO CLEAN.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning. 7.7.4.1.7 Exposed utility service lines and pipes, including lines for fire detection and protection systems, shall be installed so they do not obstruct or prevent cleaning.
Item No.: 21
Site: Other-MAIN GALLEY
Violation: NO THERMOMETER WAS PROVIDED IN THE REACH-IN REFRIGERATOR
Recommendation: 7.4.2.4.9.1 Temperature measuring devices shall conform to the following guidelines: (1) In a mechanically refrigerated or hot-food storage unit, the sensor of a temperature measuring device shall be located to measure the air temperature in the warmest part of a mechanically refrigerated unit and in the coolest part of a hot-food storage unit.
Item No.: 21
Site: Other-MAIN GALLEY
Violation: BROKEN THERMOMETERS WERE FOUND IN REACH-IN REFRIGERATORS.
Recommendation: 7.4.5.2.1.3 Ambient air temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
Item No.: 19
Site: Other-MAIN GALLEY
Violation: RAW EGG WHITES WERE STORED UNCOVERED.
Recommendation: 7.3.3.2.1.1 Food shall be protected from cross-contamination by: (4) Storing the food in packages, covered containers, or wrappings.
Item No.: 16
Site: Other-MAIN GALLEY
Violation: SALMON APPETIZER ON CRACKERS MADE THE DAY BEFORE WERE STORED IN THE DAILY USE REFRIGERATOR AT 51°F.
Recommendation: 7.3.5.3.1.1 Potentially hazardous food shall be maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above,; or (2) At 5°C (41°F) or less.
Item No.: 27
Site: Other-MAIN GALLEY
Violation: A COOKING PAN WAS SOILED WITH DRIED FOOD RESIDUE.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Other-MAIN GALLEY
Violation: SEVERAL PLACES IN THE DECK AND DRAINAGE AREAS WERE IN DISREPAIR.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 27
Site: Other-MAIN GALLEY
Violation: THE COOKING OIL STORAGE AREA WAS HEAVILY SOILED WITH SPILLED OIL.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 19
Site: Other-PROVISIONS
Violation: PEELED POTATOES WERE STORED IN A CONTAINER UNDER THE CONDENSATION PLATE OF THE COOLING UNIT. CONDENSATION WAS NOTICED DRIPPING INTO THE CONTAINER OF POTATOES.
Recommendation: 7.3.3.5.1 Food shall be protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 16
Site: Other-CREW GALLEY
Violation: MILK IN CONTAINER WAS STORED AT 61°F IN THE COLD TOP REFRIGERATOR.
Recommendation: 7.3.5.3.1.1 Potentially hazardous food shall be maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above,; or (2) At 5°C (41°F) or less.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation:
Recommendation: In developing the Corrective Action Statement for this inspection, critical-item deficiencies (designated with Yes in Critical Column (worth 3 - 5 points), whether debited or not, should include standard operating procedures and monitoring procedures implemented to prevent the recurrence of the critical deficiency. Prepare Corrective Action Statement as a word processing or spreadsheet file which will be sent to USPHS / VSP as an email message attachment. Please email Corrective Action Statement to: vsp@cdc.gov Use email message subject line: SEA DREAM I - CAS - 12-16-2001.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program