Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: CRYSTAL SYMPHONY - CAS - 3/22/2004.
|
|
Recommendation:
|
|
|
Item No.:
01
|
|
Site:
Other-MEDICAL
|
|
Violation:
THE LAST TWO 24-HOUR GASTROINTESTINAL ILLNESS REPORTS SENT ON 3/21/04 AND 3/3/04, RESPECTIVELY, WERE APPROXIMATELY 1-2 HOURS LATE. THE FRONT OFFICE MANAGER WAS ADVISED THAT THE REPORTS COULD BE SENT UP TO 30 HOURS PRIOR TO ARRIVAL.
|
|
Recommendation:
4.2.1.1.1
The master, the medical staff, or other designated staff of a vessel destined for a U.S. port from a foreign port shall submit at least one standardized gastrointestinal illness report based on the number of reportable cases in the gastrointestinal illness log to the VSP no less than 24 hours, but not more than 30 hours before the vessel's expected arrival at the U.S. port.
|
|
|
Item No.:
07
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
THE CONTACT TIME FOR THE POTABLE WATER TANK DISINFECTION WAS NOT RECORDED IN THE TANK CLEANING LOG.
|
|
Recommendation:
5.3.4.1.4
Disinfection following potential contamination shall be accomplished by increasing free residual halogen to at least 50 mg/L (ppm) throughout the affected area and maintaining this concentration for 4 hours.
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
THE VESSEL DID NOT HAVE A CROSS-CONNECTION CONTROL PLAN. ONLY TWO OF THE REDUCED PRESSURE ASSEMBLIES ON THE SHIP WERE TESTED. THESE ARE ON THE EVAPORATORS.
|
|
Recommendation:
5.7.1.1.3
The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present:
(1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
5.7.2.2.2
Backflow prevention devices requiring testing, for example reduced pressure backflow preventer and double check valves with test cocks, shall be inspected and tested with a test kit at least annually. Test results showing the pressure differences on both sides of the valves shall be maintained for each device.
|
|
|
Item No.:
16
|
|
Site:
Other-TRIDENT SNACK BAR
|
|
Violation:
CONTAINERS OF TUNA SALAD AND HAM WERE AT 47°F IN UNDERCOUNTER REFRIGERATION UNIT #1201. THESE PRODUCTS WERE ON TEMPERATURE CONTROL AND WERE PREPARED ON THE 20TH OF MARCH (2 DAYS PRIOR TO THE INSPECTION).
|
|
Recommendation:
7.3.5.3.1.1
Potentially hazardous food shall be maintained:
(1) At 60°C (140°F) [roasts 54°C (130°F)] or above,; or (2) At 5°C (41°F) or less.
|
|
|
Item No.:
19
|
|
Site:
Other-LIDO
|
|
Violation:
THE LIDO BUFFET SNEEZE SHIELDS WERE OPEN ON THE ENDS. THE FOOD STORED BENEATH WAS NOT PROTECTED FROM CONTAMINATION.
|
|
Recommendation:
7.3.3.6.1
Food on display shall be protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
|
|
|
Item No.:
19
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
PUFF PASTRY WAS STORED UNCOVERED ON A ROLLING RACK IN THE PASTRY AREA.
|
|
Recommendation:
7.3.3.5.1
Food shall be protected from contamination by storing the food:
(1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
20
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
CORROSION WAS NOTED IN THE BIN AND IN THE UPPER COMPARTMENT OF ICE MACHINE GMS 21-32.
|
|
Recommendation:
7.4.1.1.2
Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be:
(1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
|
|
|
Item No.:
20
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
THE COLLAR ON THE SMALL MIXER LOCATED IN THE COFFEE/SOUP STATION COULD NOT BE REMOVED FOR CLEANING.
THIS WAS CORRECTED DURING THE INSPECTION.
|
|
Recommendation:
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
20
|
|
Site:
Other-TRIDENT BAR
|
|
Violation:
CORROSION WAS NOTED ON THE BACK WALL OF THE ICE MACHINE BIN. IT APPEARED THAT WATER WAS DRIPPING INTO THE BIN FROM THE EXTERIOR SEAM WHERE THE CUBER PORTION JOINS THE BIN.
|
|
Recommendation:
7.4.1.1.2
Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be:
(1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
|
|
|
Item No.:
20
|
|
Site:
Other-TRIDENT SNACK BAR
|
|
Violation:
CONTAINERS OF TUNA SALAD AND HAM WERE AT A TEMPERATURE OF 47° F IN UNDERCOUNTER REFRIGERATION UNIT #2001. THESE PRODUCTS HAD BEEN PREPARED ON MARCH 20, 2004. OTHER PRODUCTS IN THE REFRIGERATOR WERE TESTED AT THE PROPER TEMPERATURES. THE PRACTICE USED TO COOL THESE PRODUCTS WAS NOT ADEQUATE TO MAINTAIN PROPER FOOD TEMPERATURES.
|
|
Recommendation:
7.3.5.2.5.2
Cooling shall be accomplished using one or more of the following methods based on the type of food being cooled:
(2) When placed in cooling or cold-holding equipment, food containers in which food is being cooled shall be arranged in the equipment to provide maximum heat transfer through the container walls; and loosely covered, or uncovered if protected from overhead contamination, during the cooling period to facilitate heat transfer from the surface of the food.
|
|
|
Item No.:
20
|
|
Site:
Other-TRIDENT SNACK BAR
|
|
Violation:
THE GREASE DRIP PAN AREA OF THE GRILL WAS NOT SEALED, MAKING IT DIFFICULT TO CLEAN.
|
|
Recommendation:
7.4.1.1.2
Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be:
(1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
THE DOOR ON REFRIGERATOR GMS 22-33 WAS NOT CLOSING PROPERLY.
|
|
Recommendation:
6.3.2.2.3
Nonfood-contact equipment shall be maintained in good repair and proper adjustment including:
(2) Equipment components such as doors, seals, hinges, fasteners, and kick plates shall be kept intact, tight, and adjusted in accordance with manufacturer's specifications.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
TWO OF THE SPRAY NOZZLES ON THE FINAL RINSE ARM IN THE DISHWASH MACHINE WERE NOT FUNCTIONING. THE MACHINE WAS IN USE AT THE TIME OF THE INSPECTION.
|
|
Recommendation:
7.5.4.1.1
Warewashing equipment shall be maintained in good repair and proper adjustment including:
(1) Warewashing equipment shall be maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines. (2) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
|
|
|
Item No.:
26
|
|
Site:
Other-TRIDENT BAR
|
|
Violation:
BOTH DRINK MIXING PITCHERS WERE SOILED. THE INTERIOR BLADE GASKETS AND THE LIDS WERE ALSO SOILED.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
27
|
|
Site:
Other-TRIDENT SNACK BAR
|
|
Violation:
GREASE WAS DRIPPING FROM BENEATH THE GRILL ONTO THE COUNTER. GREASE RESIDUE WAS NOTED ON THE BACK WALL AND UNDERSIDE OF THE GRILL.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
33
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
CRACKED AND BROKEN DECK TILES, RECESSED GROUT, GAPS, SEAMS, AND PEELING SEALANT WERE NOTED ON THE DECKS, BULKHEADS, AND DECKHEADS THROUGHOUT THE FOOD SERVICE AREAS.
|
|
Recommendation:
7.7.4.2.3
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
THE DECK WAS SOILED WITH FOOD DEBRIS IN THE PASTRY DRY STORES AREA.
|
|
Recommendation:
7.7.4.2.1
Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
|
|