Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: National Geographic Sea Bird Cruise Line: Lindblad Expeditions Inspection Date: 08/24/2003 Inspection Score: 94
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 33
Site: Other-MAIN GALLEY
Violation: THE DECKS AND BULKHEADS CONTAINED GAPS, CREVICES, AND OTHER NON-EASILY CLEANABLE FEATURES.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 20
Site: Other-MAIN GALLEY
Violation: THE CUTTING BOARDS WERE SCRATCHED AND PITTED MAKING THE SURFACES NON- EASILY CLEANABLE.
Recommendation: 7.4.5.1.3 Surfaces such as cutting blocks and boards that are subject to scratching and scoring shall be resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
Item No.: 27
Site: Other-MAIN GALLEY
Violation: THE BOTTOM INTERIOR OF THE LANG OVENS WERE SOILED WITH FOOD AND DEBRIS.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 16
Site: Other-MAIN GALLEY
Violation: THE RISOTTO STORED IN THE REACH-IN REFRIGERATOR WAS PREPARED THREE DAYS EARLIER AND HAD A TEMPERATURE READING OF 47° F.
Recommendation: 7.3.5.3.1.1 Potentially hazardous food shall be maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above,; or (2) At 5°C (41°F) or less.
Item No.: 16
Site: Other-DRY STORE ROOM
Violation: THE INTERNAL TEMPERATURE READING OF THE SWISS CHEESE STORED IN THE REACH-IN REFRIGERATOR WAS 46° F.
Recommendation: 7.3.5.3.1.1 Potentially hazardous food shall be maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above,; or (2) At 5°C (41°F) or less.
Item No.: 20
Site: Other-FOOD SERVICE GENERAL
Violation: SEVERAL REFRIGERATION UNITS WERE NOT BEING MAINTAINED IN A STATE OF REPAIR TO PROVIDE ADEQUATE COOLING TEMPERATURES FOR THE FOODS INSIDE OF THE UNITS.
Recommendation: 7.4.5.1.1.1 Food-contact equipment shall be maintained in good repair and proper adjustment including: (1) Equipment shall be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 19
Site: Other-PROVISIONS FREEZER
Violation: THREE SMALL PANS OF BAKED CHOCOLATE CAKE WERE STORED UNCOVERED UNDER THE FAN UNIT.
Recommendation: 7.3.3.5.1 Food shall be protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program