Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seven Seas Navigator Cruise Line: Regent Seven Seas Inspection Date: 08/24/2004 Inspection Score: 94
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 26
Site: Other-PORTOFINO GALLEY-POTWASH
Violation: SEVERAL PREVIOUSLY CLEANED AND STORED AS CLEAN PANS WERE NOTED SOILED ON THE CLEAN STORAGE SHELF.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 22
Site: Other-PORTOFINO GALLEY-GLASSWASH
Violation: THE DATA LABEL WAS MISSING FROM THE GLASSWASH MACHINE.
Recommendation: 7.5.2.2.3 A warewashing machine shall be provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: 26
Site: Other-PORTOFINO GALLEY
Violation: THE ICE MACHINE CUBER WAS SOILED.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 20
Site: Other-PORTOFINO GALLEY
Violation: THE BIN AND CUBER AREA OF THE ICE MACHINE WAS HEAVILY CORRODED IN AREAS.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Item No.: 26
Site: Other-PORTOFINO BUFFET LINE
Violation: NUMEROUS (MORE THAN TEN) PREVIOUSLY CLEANED PLATES WERE NOTED SOILED AND WERE ON THE BUFFET LINE FOR SERVICE.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 34
Site: Other-POOL BAR
Violation: THE WATER INLET LINE TO THE ICE MACHINE FILTER WAS CRACKED AND LEAKED INTO THE TECHNICAL AREA.
Recommendation: 7.7.3.3.1 A plumbing system in a food area shall be maintained in good repair.
Item No.: 19
Site: Other-POOL BAR
Violation: THE LEAKING FILTER IN THE TECHNICAL AREA OF THE ICE MACHINE WAS DRIPPING WATER INTO THE ICE BIN. THE ICE MACHINE WAS TAKEN OUT OF SERVICE.
Recommendation: 7.3.3.5.2 Food may not be stored: (1) In locker rooms; (2) In toilet rooms; (3) In dressing rooms; (4) In garbage rooms; (5) In mechanical rooms; (6) Under sewer lines that are not continuously sleeve welded; (7) Under leaking water lines, including leaking automatic fire sprinkler heads, or under lines on which water has condensed; (8) Under open stairwells; or (9) Under other sources of contamination from nonfood items such as ice blocks, ice carvings and flowers.
Item No.: 26
Site: Other-NAVIGATOR LOUNGE
Violation: THE INTERIOR FOOD CONTACT SURFACES OF THE BLENDER AND BLENDER COVER WERE SOILED.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE POTABLE WATER PIPE EXTENDED INTO THE FLOOD RIM OF THE TECHNICAL WATER FUNNEL, RESULTING IN THE AIR GAP NOT MAINTAINED.
Recommendation: 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems. 5.7.1.2.2 Air gaps shall be at least twice the diameter of the delivery fixture opening and a minimum of 3 cm (1 inch).
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME: SEVEN SEAS NAVIGATOR - CAS - [INSPECTION DATE: 08/24/2004] .
Recommendation:
Item No.: 20
Site: Other-DECK 5 VEGETABLE PREPARATION
Violation: THE CUTTING BOARDS WERE SEVERELY PITTED AND SCORED, WHICH MADE CLEANING DIFFICULT.
Recommendation: 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 22
Site: Other-MAIN GALLEY - POTWASH
Violation: THE POTWASH MACHINE HAS BEEN OUT-OF-SERVICE FOR OVER A WEEK.
Recommendation: 7.5.4.1.1 Warewashing equipment shall be maintained in good repair and proper adjustment including: (1) Warewashing equipment shall be maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines. (2) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
Item No.: *
Site: Other-COMMENT
Violation: THE INTERIOR FOOD CONTACT AND NON-FOOD CONTACT SURFACES OF THE ICE MACHINES WERE SEVERELY CORRODED. RECOMMEND THAT THE ICE MACHINES BE REPLACED OR RETROFITTED TO PROVIDE SMOOTH EASILY CLEANABLE SURFACES.
Recommendation:
Item No.: 26
Site: Other-PORTOFINO GALLEY-DISHWASH
Violation: SEVERAL PREVIOUSLY CLEANED PLATES AND BOWLS WERE NOTED SOILED AND STORED ON THE CLEAN DISHWARE SHELF.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 33
Site: Other-PORTOFINO BUFFET
Violation: THE FLOOR DRAIN WAS SOILED BENEATH THE BUFFET LINE AND STANDING STAGNATE LIQUID WAS PRESENT.
Recommendation: 7.7.4.2.1 Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
Item No.: 26
Site: Other-POOL BAR
Violation: THE ICE BIN AND CUBER AREA OF THE ICE MACHINE WAS SOILED.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 33
Site: Other-POOL BAR
Violation: STAGNATE LIQUID WAS NOTED BENEATH THE SERVICE BUFFET LINE AT THE POOL GRILL. THE FLOOR DRAIN WAS CLOGGED AND SOILED.
Recommendation: 7.7.4.2.1 Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
Item No.: 19
Site: Other-NAVIGATOR LOUNGE
Violation: TRAYS OF ROLLS AND CUT MELON WERE LOCATED ON A TABLE IN THE NAVIGATOR BAR WITHOUT A SNEEZE GUARD TO PROTECT THE FOOD FROM COUGHS AND SNEEZES.
Recommendation: 7.3.3.6.1 Food on display shall be protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
Item No.: 20
Site: Other-FOOD SERVICE GENERAL
Violation: CUTTING BOARDS WERE NOTED PITTED AND SCORED, WHICH MADE CLEANING DIFFICULT.
Recommendation: 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 26
Site: Other-BEVERAGE STATION
Violation: A CORROSION RESIDUE WAS NOTED ON THE FOOD CONTACT SURFACES OF THE PLASTIC ICE CHUTES IN ICE MACHINES #2 AND #3.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 20
Site: Other-BEVERAGE STATION
Violation: CORROSION WAS NOTED ON THE INSIDE OF THE ICE BIN OF MACHINE #3.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Item No.: 22
Site: Other-CREW GALLEY - WAREWASH
Violation: THE MECHANIZED CONVEYOR BELT ON THE WAREWASH MACHINE WAS NOT FUNCTIONING PROPERLY. MANY RACKS WOULD HAVE TO BE PLACED INTO THE UNIT IN ORDER TO MOVE ONE THROUGH THE WASH CYCLE.
Recommendation: 7.5.4.1.1 Warewashing equipment shall be maintained in good repair and proper adjustment including: (1) Warewashing equipment shall be maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines. (2) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
Item No.: 33
Site: Other-PROVISIONS
Violation: THE DECKING IN THE PROVISION HALLWAYS WAS NOT EASY TO CLEAN DUE TO THE ROUGH FEATURES OF THE PAINTED STEEL DECK.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program