Cruise Ship: Celebrity Infinity Cruise Line: Celebrity Cruises Inspection Date: 01/04/2004 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 23
Site: Other-MAIN GALLEY
Violation: THE WASH TEMPERATURE FOR THE GLASSWASHER WAS 145° F. THE DATA PLATE STATES THE WASH TEMPERATURE SHOULD BE A MINIMUM OF 150° F.
Recommendation: 7.5.4.2.2 The temperature of the wash solution in spray type warewashers that use hot water to sanitize may not be less than: (1) For a stationary-rack, single-temperature machine, 74°C (165°F); (2) For a stationary-rack, dual-temperature machine, 66°C (150°F); (3) For a single-tank, conveyor, dual-temperature machine, 71°C (160°F); or (4) For a multitank, conveyor, multitemperature machine, 66°C (150°F).
Item No.: 21
Site: Other-MAIN GALLEY-HOT GALLEY
Violation: LOOSE PEELING SEALANT WAS NOTED IN THE VENTILATION HOOD AT THE TILTING PAN STATION.
Recommendation: 7.4.2.1.2 Nonfood-contact surfaces of equipment and utensils shall be designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
Item No.: 33
Site: Other-MAIN GALLEY
Violation: RECESSED GROUTING WAS NOTED AROUND THE DECK DRAINS.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 37
Site: Other-MAIN GALLEY - BAKERY
Violation: A HEAVY ACCUMULATION OF CONDENSATE WAS NOTED ON THE DECKHEAD ABOVE THE BAKING OVENS.
Recommendation: 7.7.6.1.1 All food preparation, warewashing, and toilet rooms shall have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item No.: 22
Site: Other-CREW GALLEY
Violation: THE PRESSURE GAUGE ON THE GLASS WASHER WAS READING 5 POUNDS PER SQUARE INCH (PSI) ABOVE THE 15-25 PSI RANGE.
Recommendation: 7.5.2.1.2 Pressure measuring devices that display the pressures in the water supply line for the fresh hot water sanitizing rinse shall have increments of 7 kilopascals (1 pounds per square inch) or smaller and shall be accurate to ± 14 kilopascals (± 2 pounds per square inch) in the 100-170 kilopascals (15-25 pounds per square inch) range.
Item No.: 33
Site: Other-STAFF MESS
Violation: THE CARPET WAS VERY WORN MAKING CLEANING DIFFICULT.
Recommendation: 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
Item No.: 19
Site: Other-PROVISIONS-BEVERAGE AREA
Violation: THREE BOXES OF OVA MILANO CHOCOLATE FAVORS WERE STORED ON THE DECK.
Recommendation: 7.3.3.5.1 Food shall be protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 08
Site: Other-POOL BAR
Violation: THE BACKFLOW PREVENTER HAD A CONTINUOUS LEAK AT THE MULTI-FLOW BEVERAGE DISPENSER STATION.
Recommendation: 5.7.2.2.1 Backflow prevention devices should be periodically inspected and any failed units shall be replaced.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
Item No.: 21
Site: Other-LIDO - HOT GALLEY
Violation: THE TWO DOUBLE DOOR HOT HOLDING CABINETS HAD MOUNTED THERMOMETERS WHICH COULD NOT BE VIEWED DUE TO CLOUDY COVERS.
Recommendation: 7.4.2.3.2 Ambient air temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be easily readable and accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit shall be accurate to ±3°F in the intended range of use.
Item No.: 33
Site: Other-LIDO - HOT GALLEY
Violation: BULKHEADS BELOW COOKING EQUIPMENT AND COUNTERS WERE SOILED WITH DIRT AND GREASE RESIDUE THROUGHOUT THE HOT SECTION.
Recommendation: 7.7.4.2.1 Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
Item No.: 33
Site: Other-LIDO - HOT GALLEY
Violation: THERE WAS AN OPEN PANEL AT THE BULKHEAD DIRECTLY BENEATH THE SOUP KETTLE.
Recommendation: 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair. Provide a stainless steel cover/door for this opening.
Item No.: 36
Site: Other-LIDO - BUFFET
Violation: SEVERAL LIGHT FIXTURES ALONG THE PORT AND STARBOARD BUFFET LINES WERE NOT FUNCTIONING.
Recommendation: Replace light bulbs that are not working.
Item No.: 24
Site: Other-LIDO - DISHWASH
Violation: THE FINAL HOT WATER SANITIZING RINSE TEMPERATURE OF THE IN-USE FLIGHT-TYPE DISHWASH MACHINE REACHED NO HIGHER THAN 159 °F AT THE DISH SURFACE.
Recommendation: 7.5.6.1.2 In a mechanical operation, the temperature of the fresh hot water sanitizing rinse as it enters the manifold may not be more than 90°C (194°F), or less than: (1) For a stationary rack, single temperature machine, 74°C (165°F); or (2) For all other machines, 82°C (180°F). (3) A utensil surface temperature of 71°C (160°F) as measured by an irreversible registering temperature indicator shall be achieved. (4) The maximum temperature of 90°C (194°F), does not apply to the high pressure and temperature systems with wand-type, hand-held, spraying devices used for the in-place cleaning and sanitizing of equipment such as meat saws.
Item No.: 22
Site: Other-LIDO - DISHWASH
Violation: PLATES WERE POSITIONED SO THEY OVERLAPPED IN THE CONVEYOR DISHWASH MACHINE, PREVENTING ALL SURFACES FROM BEING EXPOSED TO WASH AND RINSE WATER SPRAY. THIS ITEM WAS CORRECTED DURING THE INSPECTION.
Recommendation: 7.5.5.3.3 Soiled items to be cleaned in a warewashing machine shall be loaded into racks, trays, or baskets or onto conveyors in a position that: (1) Exposes the items to the unobstructed spray from all cycles; and (2) Allows the items to drain.
Item No.: 22
Site: Other-LIDO - DISHWASH
Violation: THE MOUNTED FINAL RINSE THERMOMETER ON THE FLIGHT-TYPE DISHWASH MACHINE REGISTERED APPROXIMATELY 40 °F HIGHER THAN THE PLATE LEVEL TEMPERATURE, MAKING IT 20 °F OUT OF CALIBRATION.
Recommendation: 7.5.2.1.1 Water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit shall designed to be accurate to ±3°F in the intended range of use.
Item No.: 36
Site: Other-BACK GRILL
Violation: THE FLUORESCENT LIGHTS IN THE DECKHEAD OF THE SERVICE AREA WERE NOT SHIELDED OR SHATTER-RESISTANT.
Recommendation: 7.7.5.2.1 Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service, and single-use articles.
Item No.: 33
Site: Other-BACK GRILL
Violation: THE DECKHEAD PANELS OVER THE FRONT SERVICE SECTION WERE SOILED WITH A DIRT/GREASE RESIDUE.
Recommendation: 7.7.4.2.1 Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
Item No.: 36
Site: Other-ICE CREAM PARLOR PORT AND STARBOARD
Violation: THE FLUORESCENT LIGHTS IN THE DECKHEAD OF THE SERVICE AREA WERE NOT SHIELDED OR SHATTER-RESISTANT.
Recommendation: 7.7.5.2.1 Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service, and single-use articles.
Item No.: 22
Site: Other-SCULLERY - DECK 10
Violation: THE MOUNTED FINAL RINSE THERMOMETER FOR THE GLASSWASH MACHINE REGISTERED APPROXIMATELY 20 °F OUT OF CALIBRATION WHEN COMPARED TO THE PLATE LEVEL TEMPERATURE.
Recommendation: 7.5.2.1.1 Water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit shall designed to be accurate to ±3°F in the intended range of use.
Item No.: 41
Site: Other-CHILD ACTIVITY CENTER - FUN FACTORY
Violation: THE CHILDREN'S TOILET ROOM WAS NOT PROVIDED WITH A SUPPLY OF SANITARY WIPES.
Recommendation: Ensure that sanitary wipes are provided in the children's toilet room.
Item No.: 40
Site: Other-INTEGRATED PEST MANAGEMENT (IPM)
Violation: THERE WAS NO WRITTEN DOCUMENTATION THAT THE SECOND OFFICER WAS TRAINED, YET HE DOES USE/APPLY PESTICIDES.
Recommendation: Ensure written documentation of training is provided for all pesticide applicators.
Item No.: 02
Site: Other-MEDICAL
Violation: ON THE CRUISE OF 27 NOVEMBER TO 7 DECEMBER 2003 THERE WERE TWO PASSENGERS WHO WERE ISSUED ANTIDIARRHEAL MEDICATIONS BUT WERE NOT NOTED ON THE GASTROINTESTINAL ILLNESS SURVEILLANCE LOG FOR THAT CRUISE.
Recommendation: 4.1.2.1.3 The log shall list: (1) All reportable cases of gastrointestinal illness; (2) All passengers and crew members who are dispensed antidiarrheal medication from the master of the vessel, the medical staff, or other designated staff.
Item No.: 10
Site: Other-POOLS AND WHIRLPOOL SPAS
Violation: THERE WAS NO MONTHLY CORE SAMPLE COLLECTED FROM THE SPA SAND FILTERS AND INSPECTED FOR EXCESSIVE ORGANIC MATERIAL USING A SEDIMENTATION METHOD. A COPY OF A RECOMMENDED SEDIMENTATION METHOD WAS LEFT ON THE SHIP DURING THE INSPECTION.
Recommendation: Ensure monthly core samples are collected from the spa sand filters and are inspected for excessive organic material.
Item No.: 03
Site: Other-WATER PRODUCTION
Violation: A POTABLE WATER BUNKERING/PRODUCTION LOG REVIEW REVEALED THAT WHILE AT ANCHORAGE AT LAHAINA (11/22-25), KONA (11/21-22), AND HILO (11/20-21) THE SHIP WAS PRODUCING WATER THROUGH THE ONBOARD EVAPORATOR PLANTS IN CONJUNCTION WITH HEAT PRODUCED FROM THE GAS TURBINES. ALTHOUGH THIS WATER WAS REPORTED BY THE SHIP'S ENGINEERING STAFF TO BE USED TO FILL TECHNICAL LAUNDRY WATER TANKS ONLY, THE DOCUMENTATION OF THE PROCESS WAS IN THE POTABLE WATER PRODUCTION LOG BOOK WITH NO ENTRIES OF THE TANKS WHICH WERE FILLED.
Recommendation: 5.1.2.1.1 A distillation plant or other process that supplies water to the vessel's potable water system shall not operate in polluted or harbor areas. A distillation plant or other process that can be used to make potable water can not be operated in polluted or harbor areas even if it is to make non-potable or technical water. Using a distillation plant or other process in polluted or harbor areas can subject this equipment to contamination.