|
|
|
Item No.:
*
|
|
Site:
Other-MEDICAL COMMENT
|
|
Violation:
THERE NEEDS TO BE SOME DOCUMENTATION THAT INDICATES CREW MEMBERS ARE ISOLATED FOR 72 HOURS WHEN THEY ARE DIAGNOSED WITH A GASTROINTESTINAL ILLNESS.
|
|
Recommendation:
|
|
|
Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
|
|
Recommendation:
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER - POOP DECK
|
|
Violation:
THERE WAS A HOSE WITH A NOZZLE ATTACHED TO A DECK TAP THAT DIDN'T HAVE THE APPROPRIATE BACKFLOW PREVENTER INSTALLED.
|
|
Recommendation:
Install the appropriate continuous pressure backflow device on this deck tap.
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
THE SHIP DOES HAVE REDUCE PRESSURE BACKFLOW ASSEMBLIES FOR THE INTERNATIONAL SHORE CONNECTIONS; HOWEVER, THEY ARE NOT PERMANENTLY INSTALLED ON THE LINES.
|
|
Recommendation:
Install these backflow preventers as a permenant fixture.
|
|
|
Item No.:
15
|
|
Site:
Other-PROVISIONS - DRY STORES
|
|
Violation:
A FEW CANS WERE NOTED WITH MINOR DENTS. THERE WAS ONE CAN THAT HAD A SEVERE DENT IN THE SIDE OF THE CAN.
|
|
Recommendation:
7.3.2.2.5
Food packages shall be in good condition and protect the integrity of the contents so that the food is not exposed to adulteration or potential contaminants. Canned goods with dents on end or side seams may not be used.
|
|
|
Item No.:
20
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
THE FOOD CONTACT SURFACES OF OLDER EQUIPMENT SUCH AS REFRIGERATORS HAD EXPOSED WIRES, COOLING COILS AND OTHER DIFFICULT TO CLEAN FEATURES.
|
|
Recommendation:
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints.
|
|
|
Item No.:
21
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
THE NON-FOOD CONTACT SURFACES OF THE OLDER EQUIPMENT HAD DIFFICULT TO CLEAN FEATURES SUCH AS GAPS, SEAMS AND HOLES.
|
|
Recommendation:
7.4.2.2.6
Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY - HOT GALLEY
|
|
Violation:
THERE WAS A DIFFICULT TO CLEAN GAP BETWEEN THE NEWLY INSTALLED STEAM KETTLE AND THE ADJACENT UNDERCOUNTER REFRIGERATION UNIT.
|
|
Recommendation:
Profile this gap with a stainless steel strip.
|
|
|
Item No.:
21
|
|
Site:
Other-CREW MESS
|
|
Violation:
THE INTERIOR SPACE OF THE VITALITY JUICE MACHINE WAS DIFFICULT TO CLEAN DUE TO EXPOSED PIPING AND WIRING.
|
|
Recommendation:
7.4.2.2.6
Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY - DISHWASH MACHINE
|
|
Violation:
THE SHORT CURTAIN WAS NOT PLACE IN-BETWEEN THE FINAL RINSE CYCLE AND THE HOT WATER SANITIZING CYCLE.
|
|
Recommendation:
7.5.2.2.4
Warewashing machine wash and rinse tanks shall be equipped with baffles, curtains, or other means to minimize internal cross-contamination of the solutions in wash and rinse tanks.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY - DISHWASH
|
|
Violation:
THE FINAL SANITIZING SPRAY NOZZLES HAD AN ERRATIC SPRAY PATTERN.
|
|
Recommendation:
Unclog the final rinse nozzles.
|
|
|
Item No.:
22
|
|
Site:
Other-CREW MESS
|
|
Violation:
THE SANITIZING SOLUTION IN THE BUCKET WAS DIRTY.
|
|
Recommendation:
7.5.4.1.5
The wash, rinse, and sanitize solutions shall be maintained clean.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY - POTWASH
|
|
Violation:
THE POT WASH AREAS HAS BEEN CONVERTED INTO A CLEAN POT STORAGE AREA WITH ONLY THE SANITIZE SINK REMAINING BUT NOT BEING USED. POT SCRUBBING IS DONE IN THE DISHWASH AREA BUT THERE IS ONLY AN OVERHEAD SPRAY AND NO SINK. THEN THE POTS AND PANS ARE RUN THROUGH THE DISHWASHING MACHINE TO COMPLETE THE WASHING AND SANITIZING OF THESE ITEMS.
|
|
Recommendation:
The current procedure may not be adequate to properly sanitize the larger pots that are used in the galley.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY - DISHWASH
|
|
Violation:
A FEW PEVIOUSLY CLEANED CUPS AND EGG HOLDERS WERE FOUND SOILED WITH A FOOD RESIDUE.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY - CLEAN STORAGE AREA
|
|
Violation:
CLEAN POTS AND TONGS WERE NOTED HANGING IN DIRECT CONTACT WITH THE BULKHEAD.
|
|
Recommendation:
7.5.7.3.1
Cleaned equipment and utensils, laundered linens, and single-service and single-use articles shall be stored:
(1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
29
|
|
Site:
Other-MAN BAR AND PIANO BAR
|
|
Violation:
THE HANDWASH STATION FOR EACH OF THESE BARS WAS LOCATED IN THE PANTRIES. THIS REQUIRED PASSING THROUGH NORMALLY CLOSED DOORS WITH HANDLES.
|
|
Recommendation:
7.7.1.1.2
The handwashing facility shall be located within 8 m (25 feet) of all parts of the area and should not be located in an adjacent area that requires passage through a closed door.
|
|
|
Item No.:
33
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
THE DECKS IN THE MAIN GALLEY, THE BULKHEADS AND DECKHEADS IN THE OLDER FOOD AREAS HAD OPEN SEAMS, EXPOSED WIRES AND PIPING AND OTHER DIFFICULT TO CLEAN FEATURES.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
|
|
|
Item No.:
40
|
|
Site:
Other-INTERGRADED PEST MANAGEMENT
|
|
Violation:
THE LOGS INDICATE THAT NIGHTLY MONITORING IS BEING PERFORMED; HOWEVER, THE PLAN DID NOT MENTION IT. THE LOGS WOULD ALSO INDICATE THAT THE EFFECTIVENESS OF THE PESTICIDES WOULD BE EVALUATED, BUT THE PLAN DID NOT MENTION THIS.
|
|
Recommendation:
8.1.1.1.2
The Integrated Pest Management Plan shall set a schedule for periodic monitoring inspections including some at night.
8.1.2.1.1
The Integrated Pest Management Plan shall include a record of pesticides used and their effectiveness.
|
|