Cruise Ship: Caribbean Princess Cruise Line: Princess Cruises Inspection Date: 10/02/2004 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE LOCATIONS OF THE FOUR MONTHLY E. COLI TESTS WERE NOT CHANGED EVERY MONTH.
Recommendation: 5.6.1.1.1 A minimum of four potable water samples per month shall be collected and analyzed for the presence of Escherichia coli. Samples shall be collected randomly from locations forward, aft, upper, and lower decks of the vessel.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE PH TEST RESULTS FROM THE SHORE SIDE WATER SUPPLY WERE NOT RECORDED PRIOR TO BUNKERING.
Recommendation: 5.2.1.2.1 A halogen demand test and pH shall be conducted on the shore-side water supply before starting the bunkering process to establish the correct halogen dosage.
Item No.: 10
Site: Other-WHIRLPOOL SPAS
Violation: A CORE SAMPLE WAS NOT CONDUCTED ON THE FILTER MEDIA ON A MONTHLY BASIS.
Recommendation: 6.3.1.1.5 The granular filters shall be opened at least monthly and examined for cracks, mounds, or holes in the filter media. A core sample of the filter media shall be inspected for excessive organic material accumulation using a recommended sedimentation method.
Item No.: 20
Site: Other-LIDO GALLEY
Violation: SOFT SEALANT WAS NOTED ON THE BACK PLATE OF THE MEAT SLICER.
Recommendation: Remove this soft sealant and replace with a hard food grade sealant.
Item No.: 25
Site: Other-MAIN GALLEY
Violation: FOUR DAMP WIPING CLOTHS WERE NOT STORED IN THE SANITIZING SOLUTION.
Recommendation: 7.3.3.4.4.2 Wiping cloths shall be restricted to the following: (2) Cloths used for wiping food spills shall be dry and used for wiping food spills from tableware and single-service articles or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment.
Item No.: 30
Site: Other-CAFÉ CARIBE PANTRY
Violation: A COVERED WASTE RECEPTACLE WAS NOT PROVIDED IN THE TOILET ROOM.
Recommendation: 7.7.1.2.5 Easily cleanable covered receptacles shall be provided for hygiene waste materials.