|
|
|
Item No.:
28
|
|
Site:
Other-DINING ROOM
|
|
Violation:
CASES OF SINGLE SERVICE ITEMS WERE STORED ON THE DECK.
|
|
Recommendation:
7.5.7.3.1
Cleaned equipment and utensils, laundered linens, and single-service and single-use articles shall be stored:
(1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and
(3) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
38
|
|
Site:
Other-MAIN GALLEY SILVER CLEANING
|
|
Violation:
THE MOP WAS NOT HUNG TO DRY AFTER USE.
|
|
Recommendation:
7.7.7.1.4
After use, mops shall be placed in a position that allows them to air-dry without soiling walls, equipment, or supplies.
|
|
|
Item No.:
30
|
|
Site:
Other-MAIN GALLEY TOILET ROOM
|
|
Violation:
THE "WASH HANDS AFTER USING THE TOILET" SIGN WAS POSTED OUT SIDE OF THE TOILET ROOM.
|
|
Recommendation:
7.7.1.2.3
Signs shall be conspicuously posted on the bulkhead adjacent to the door of the toilet, reading "WASH HANDS AFTER USING TOILET " in a language that the food employees understand.
|
|
|
Item No.:
30
|
|
Site:
Other-MAIN GALLEY TOILET ROOM
|
|
Violation:
TOILET TISSUE WAS NOT PROVIDED.
|
|
Recommendation:
7.7.1.3.5
A supply of toilet tissue shall be provided at each toilet at all times.
|
|
|
Item No.:
33
|
|
Site:
Other-MAIN GALLEY-TOILET ROOM
|
|
Violation:
THE VINYL FLOOR COVERING WAS IN DISREPAIR MAKING CLEANING DIFFICULT.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
THERE WERE A FEW AREAS WHERE EXCESS WATER WAS NOTED ON THE DECK.
|
|
Recommendation:
7.7.4.2.1
Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
|
|
|
Item No.:
16
|
|
Site:
Other-MAIN GALLEY-COFFEE STATION
|
|
Violation:
PITCHERS OF CREAM AND MILK WERE TESTED AT 46°F IN THE UNDERCOUNTER REFRIGERATION UNIT. THESES ITEMS WERE ON TIME CONTROL AND HAD BEEN OUT FOR THE BREAKFAST SERVICE. ACCORDING TO THE LOG THEY WERE TO BE DISCARDED BY 9 A.M. WHICH WAS 3 HOURS AFTER THEY WERE REMOVED FROM TEMPERATURE CONTROL. THE TEMPERATURE OF THESE ITEMS WAS TAKEN AT 9:15 A.M.
|
|
Recommendation:
7.3.5.3.5
If time only, rather than time in conjunction with temperature, is used as the public health control for a working supply of potentially hazardous food before cooking, or for ready-to-eat potentially hazardous food that is displayed or held for service for immediate consumption:
(1) The food shall be marked or otherwise identified to indicate the time that is 4 hours past the point in time when the food is removed from temperature control; (2) The food shall be cooked and served, served if ready-to-eat, or discarded, within 4 hours from the time when the food is removed from temperature control; and (3) The food in unmarked containers or packages or marked to exceed a 4 hour limit shall be discarded.
7.3.5.3.6
Written procedures that ensure compliance with these guidelines shall be maintained on the vessel and made available to the VSP, upon request.
If the vessel plan call for 3 hours rather than 4 hour then this should be adhered to. In addition, if pitchers of cream and milk are out for service then placed in the refrigerator they should be identified as being on time control to differentiate them from the other items in the unit that are not on time control.
|
|
|
Item No.:
30
|
|
Site:
Other-MAIN GALLEY-COFFEE STATION
|
|
Violation:
A "WASH HANDS OFTEN" SIGN WAS NOT POSTED OVER THE HANDWASH SINK.
|
|
Recommendation:
7.7.1.1.7
A sign stating "WASH HANDS OFTEN" in a language that the food employees understand shall be posted over handwashing sinks.
|
|
|
Item No.:
19
|
|
Site:
Other-MAIN GALLEY-HOT GALLEY
|
|
Violation:
AN IN USE WHISK WAS STORED IN A PITCHER OF STANDING WATER. THIS WATER WAS NOT AT 140°F.
|
|
Recommendation:
7.3.3.4.2.4
During pauses in food preparation or dispensing, food preparation and dispensing utensils shall be stored:
(4) In running water of sufficient velocity to flush particulates to the drain, if used with moist food such as ice cream or mashed potatoes.
7.3.3.4.2
During pauses in food preparation or dispensing, food preparation and dispensing utensils shall be stored:
(6) In a container of water if the water is maintained at a temperature of at least 60°C (140°F) and the container is frequently cleaned and sanitized.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY-HOT GALLEY
|
|
Violation:
THE LABELS WERE PEELING FROM THE FRONT OF THE FRYERS MAKING CLEANING DIFFICULT.
|
|
Recommendation:
7.4.1.1.9
Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
38
|
|
Site:
Other-MAIN GALLEY-HOT GALLEY
|
|
Violation:
A WIRE CLEANING BRUSH WAS STORED IN THE OVEN.
|
|
Recommendation:
7.7.7.1.2
Maintenance tools such as mops, brooms, and similar items shall be stored in a designated locker so they do not contaminate food; food-contact surfaces of utensils; and equipment; linens, and single-service and single-use articles.
|
|
|
Item No.:
27
|
|
Site:
Other-MAIN GALLEY-HOT GALLEY
|
|
Violation:
THE REFRIGERATION UNIT TECHNICAL COMPARTMENTS ACROSS FROM THE COOKING STATIONS WERE SOILED WITH GREASE.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
16
|
|
Site:
Other-MAIN GALLEY-COLD GALLEY
|
|
Violation:
IT WAS NOT CLEAR FROM A REVIEW OF THE LOGS THAT FOODS WERE COOLED FROM 140°F TO 70°F IN 2 HOURS. THE LOG DID NOT INDICATE THE TEMPERATURES OF THE FOODS WHEN PLACED IN THE BLAST CHILLER. IN ADDITION, THE FOOD ITEMS LISTED IN THE LOG WERE AT TIMES VERY GENERAL. ON THE DATE OF THE INSPECTION THE LOG INDICATED POTATOES AND THIS VESSEL COOLS DOWN SEVERAL DIFFERENT TYPES OF POTATO PREPARATIONS.
|
|
Recommendation:
7.3.5.2.1
Cooked potentially hazardous food shall be cooled:
(1) Within 2 hours, from 60°C (140°F) to 21°C (70°F); and (2) Within 4 hours, from 21°C (70°F) to 5°C (41°F) or less.
|
|
|
Item No.:
28
|
|
Site:
Other-PASTRY AND BAKERY
|
|
Violation:
THE UNDER SURFACE OF THE DOUGH ROLLER BELTS WERE WET.
|
|
Recommendation:
7.5.7.3.2
Clean equipment and utensils shall be stored:
(1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY-DISHWASH
|
|
Violation:
THE NEEDLE ON THE FINAL RINSE TEMPERATURE GAUGE CYCLED PAST 220°F. THE FINAL RINSE WAS TESTED AT 172°F.
|
|
Recommendation:
7.5.2.1.1
Water temperature measuring devices:
(1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit shall designed to be accurate to ±3°F in the intended range of use.
|
|
|
Item No.:
27
|
|
Site:
Other-BAKERY
|
|
Violation:
THE OVEN HANDLES WERE SOILED.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
34
|
|
Site:
Other-CREW GALLEY
|
|
Violation:
THE WATER WAS DRAINING VERY SLOWLY FROM THE HANDWASH SINK BOWL CAUSING IT TO FILL UP DURING HANDWASHING. THIS SINK WAS LOCATED NEAR THE ENTRANCE TO THE GALLEY FROM THE CORRIDOR.
|
|
Recommendation:
7.7.3.3.1
A plumbing system in a food area shall be maintained in good repair.
|
|
|
Item No.:
27
|
|
Site:
Other-CREW GALLEY
|
|
Violation:
THE DISCHARGE PIPE IN THE FRYER CABINET WAS SOILED WITH CONGEALED GREASE.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
26
|
|
Site:
Other-CREW GALLEY
|
|
Violation:
A LARGE AMOUNT OF EXCESS WATER WAS NOTED IN THE OVENS.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
37
|
|
Site:
Other-CREW GALLEY
|
|
Violation:
A LARGE AMOUNT OF EXCESS CONDENSATE WAS NOTED ON THE EDGES OF THE RATIONAL OVEN HOOD. THIS AREA WAS DIRECTLY OVER THE DOOR OF THE OVEN. THE CONDENSATE WAS LOCATED IN AN AREA WHERE IT COULD DRIP ON THE FOOD ITEMS AS THEY WERE PLACED IN TO OR REMOVED FROM THE OVENS.
|
|
Recommendation:
7.4.2.4.1
Exhaust ventilation hood systems in food preparation and warewashing areas including components such as hoods, fans, guards, and ducting shall be designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
|
|
|
Item No.:
21
|
|
Site:
Other-CREW MESS
|
|
Violation:
THE HANDLE WAS SPLIT ON A SERVING UTENSIL MAKING CLEANING DIFFICULT. THIS SERVING UTENSIL WAS IN A STORAGE BIN. THIS WAS CORRECTED DURING THE INSPECTION.
|
|
Recommendation:
7.4.1.1.9
Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
26
|
|
Site:
Other-CREW MESS
|
|
Violation:
A PREVIOUSLY CLEANED PLASTIC PITCHER WAS SOILED WITH OIL RESIDUE. A PREVIOUSLY CLEANED PLASTIC PITCHER HAD A STRONG VINEGAR ODOR.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
7.4.1.1.1
Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment may not allow the migration of deleterious substances or impart colors, odors, or tastes to food and under normal use conditions shall be safe.
|
|
|
Item No.:
15
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
THE SHELLSTOCK TAGS WERE REMOVED FROM THE CONTAINERS IN WHICH THEY WERE RECEIVED PRIOR TO USE. NOT ALL OF THE TAGS WERE FILLED IN PROPERLY.
THE RECORD KEEPING SYSTEM THAT WAS IN USE HAD A COLUMN FOR INDICATING WHEN THE SHELLSTOCK WAS SERVED. THERE WAS NO DATE FILLED IN FOR THE SHELLSTOCK RECEIVED ON 4/15/2004, 5/17/2004, 6/14/2004, AND 6/26/2004.
THERE WERE A FEW DATES WHEN THE TAGS WERE NOT AVAILABLE FOR SHELLSTOCK THAT WAS RECORDED AS RECEIVED. AS PER THE PROVISIONS MASTER THE SHELLSTOCK WAS DISCARDED. THERE WAS NO INDICATION IN THE LOG THAT THIS WAS THE CASE.
|
|
Recommendation:
7.3.2.3.2
Shellstock shellfish tags shall:
(1) Remain attached to the container in which the shellstock are received until the container is empty. (2) Be maintained by retaining shellstock tags or labels for 90 calendar days from the date the container is emptied by using an approved record keeping system that keeps the tags or labels in chronologic order correlated to the date when the shellstock are served.
7.3.2.1.7
Fish and Molluscan Shellfish Sources:
(1) Fish that are received for service shall be commercially and legally caught or harvested or otherwise approved for service by the VSP. (2) Molluscan shellfish that are recreationally caught may not be received for service. (3) Molluscan shellfish shall be obtained from sources according to law and the requirements specified in the U.S. Department of Health and Human Services, Public Health Service, Food and Drug Administration, National Shellfish Sanitation Program Guide for the Control of Molluscan Shellfish or equivalent standards; and received in interstate commerce shall be from sources that are listed in the FDA Interstate Certified Shellfish Shippers List or equivalent foreign certified shellfish listing.
|
|
|
Item No.:
16
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
THE SALMON USED FOR GRAVLAX WAS RECORDED AS FROZEN TO -20°C FROM 09/03/2004-09/09/2004. THIS WAS SIX DAYS AND NOT THE SEVEN DAYS REQUIRED.
|
|
Recommendation:
7.3.4.2.1
Before service in ready-to-eat form, raw, raw-marinated, partially cooked, or marinated-partially cooked fish other than molluscan shellfish:
(1) Shall be frozen throughout to a temperature of -20°C (-4°F) or below for 168 hours (7 days) in a freezer; or -35°C (-31°F) or below for 15 hours in a blast freezer.
|
|
|
Item No.:
21
|
|
Site:
Other-PROVISIONS-VEGETABLE PREPARATION
|
|
Violation:
THE WALK-IN DOOR HANDLE WAS ROUGH MAKING CLEANING DIFFICULT. THE HANDLE WAS REPLACED DURING THE INSPECTION.
|
|
Recommendation:
7.4.1.1.9
Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
33
|
|
Site:
Other-PROVISIONS CORRIDOR-DECK 4
|
|
Violation:
THE DECK HAD ROUGH PATCHES WHERE THE FINISH WAS DAMAGED MAKING CLEANING DIFFICULT.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
|
|
|
Item No.:
19
|
|
Site:
Other-BISTRO
|
|
Violation:
THE SNEEZE GUARD WAS TOO HIGH TO ADEQUATELY PROTECT THE FOODS.
|
|
Recommendation:
7.3.3.6.1
Food on display shall be protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
|
|
|
Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: CRYSTAL SYMPHONY - CAS - [09/21/2004] .
|
|
Recommendation:
|
|
|
Item No.:
06
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
ON 5/30 AND 7/1, THE HALOGEN ANALYZER CHART RECORDER CHARTS FOR THE DISTRIBUTION SYSTEM WERE LEFT ON THE RECORDER FOR LONGER THAN 24 HOURS.
|
|
Recommendation:
5.5.2.2.1
Halogen analyzer-chart recorder charts shall be changed, initialed, and dated daily. Charts shall contain notations of any unusual water events in the potable water system.
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
ON 8/7, 8/15, AND 8/21 THE PH AND HALOGEN DEMAND TESTS FROM THE SHORE SIDE WATER SUPPLY WERE NOT RECORDED. ON 7/18, THE PH TEST FROM THE SHORE SIDE WATER SUPPLY WAS NOT RECORDED PRIOR TO BUNKERING.
THE PRESSURE DIFFERENCES FOR THE REDUCED PRESSURE BACKFLOW PREVENTION DEVICES WERE NOT RECORDED.
THE VESSEL WAS IN THE PROCESS OF DEVELOPING A CROSS-CONNECTION CONTROL PROGRAM.
|
|
Recommendation:
5.2.1.2.1
A halogen demand test and pH shall be conducted on the shore-side water supply before starting the bunkering process to establish the correct halogen dosage.
5.7.2.2.2
Backflow prevention devices requiring testing, for example reduced pressure backflow preventer and double check valves with test cocks, shall be inspected and tested with a test kit at least annually. Test results showing the pressure differences on both sides of the valves shall be maintained for each device.
5.7.1.1.3
The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present:
(1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
|
|
|
Item No.:
10
|
|
Site:
Other-WHIRLPOOL SPAS
|
|
Violation:
THERE WERE SEVERAL DAYS SINCE THE LAST INSPECTION WHEN THE PH LEVELS IN THE WHIRLPOOLS WAS TOO HIGH. NO CORRECTIVE ACTIONS WERE WRITTEN IN THE LOGS TO ADDRESS THIS.
A CORE SAMPLE WAS NOT USED FOR THE MONTHLY SEDIMENTATION TEST FOR THE GRANULAR FILTERS. IT WAS STATED THAT THE TEST WAS DONE BY TAKING A CUP AND SCOOPING THE SAND OUT OF THE FILTER.
|
|
Recommendation:
6.3.1.2.2
The whirlpool spa water shall be maintained with a pH between 7.2 and 7.8.
6.3.1.1.5
The granular filters shall be opened at least monthly and examined for cracks, mounds, or holes in the filter media. A core sample of the filter media shall be inspected for excessive organic material accumulation using a recommended sedimentation method.
|
|
|
Item No.:
34
|
|
Site:
Other-TRIDENT ICE CREAM BAR
|
|
Violation:
A LEAK WAS NOTED AT THE FAUCET OF THE DIPPER WELL.
|
|
Recommendation:
Repair the leak.
|
|
|
Item No.:
20
|
|
Site:
Other-TRIDENT BAR PANTRY
|
|
Violation:
PEELING SEALANT WAS NOTED IN THE BIN OF THE ICE MACHINE MAKING CLEANING DIFFICULT.
|
|
Recommendation:
7.4.1.1.2
Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be:
(1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
22
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
THE DATA PLATES ON THE GLASSWASH MACHINES IN ROOM SERVICE PANTRY DECK 7 FORWARD AND THE COVE BAR PANTRY ONLY LISTED THE WASH AND RINSE TEMPERATURES AND NOT THE CYCLE TIMES.
|
|
Recommendation:
7.5.2.2.3
A warewashing machine shall be provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the:
(1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
|
|