Item No.:
20
|
|
Site:
Food Service General-
|
|
Violation:
SLOTTED FASTENERS WERE NOTED IN THE ICE/WATER CONTACT SURFACES OF THE UPPER COMPARTMENT AT THE ICE MACHINES, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Replace slotted fasteners with fasteners that have smooth, easily cleanable surfaces.
|
|
|
Item No.:
33
|
|
Site:
Food Service General-
|
|
Violation:
THERE WERE SEVERAL AREAS THAT HAD WORN GROUT AROUND DECK TILES AND PEELING SOFT SEALANT. LOOSE PROFILE STRIPS WERE NOTED IN SEVERAL AREAS.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
29
|
|
Site:
Galley-
|
|
Violation:
ICE WAS DUMPED IN TO THE HANDWASH SINK NEAR THE PORT SIDE ICE MACHINE AREA.
|
|
Recommendation:
Ensure that handwashing facilities are used for no other purpose and are accessible at all times.
|
|
|
Item No.:
21
|
|
Site:
Galley-LIDO PREPARATION
|
|
Violation:
A SMALL AMOUNT OF LOOSE SEALANT WAS NOTED INSIDE AN UNDERCOUNTER STORAGE UNIT.
|
|
Recommendation:
Remove loose sealant.
|
|
|
Item No.:
26
|
|
Site:
Galley-PASTRY
|
|
Violation:
EXCESS WATER WAS NOTED IN THE MIXER COLLAR.
|
|
Recommendation:
Remove excess water from the mixer collar.
|
|
|
Item No.:
25
|
|
Site:
Galley-PASTRY
|
|
Violation:
THE MOIST CLOTH WAS NOT FULLY IMMERSED IN THE SANITIZE SOLUTION FOR THE 3-BUCKET SYSTEM.
|
|
Recommendation:
Ensure that dry or wet cloths that are used with raw animal foods are kept separate from cloths used for other purposes, and wet cloths used with raw animal foods are kept in a separate sanitizing solution.
|
|
|
Item No.:
29
|
|
Site:
Galley-GARDE MANGER
|
|
Violation:
A PLATE TROLLEY WAS STAGED IN FRONT OF THE HANDWASH SINK.
|
|
Recommendation:
Ensure that handwashing facilities are used for no other purpose and are accessible at all times.
|
|
|
Item No.:
15
|
|
Site:
Galley-LIDO PANTRY
|
|
Violation:
A CAN OF PRUNE JUICE WAS NOTED SEVERELY DENTED ON THE TOP SEAM. THE CAN WAS FOUND INSIDE THE WALK-IN REFRIGERATOR. THE CAN OF PRUNE JUICE WAS DISCARDED.
|
|
Recommendation:
Ensure that food packages are in good condition and protect the integrity of the contents so that the food is not exposed to adulteration or potential contaminants. Canned goods with dents on end or side seams may not be used.
|
|
|
Item No.:
14
|
|
Site:
Galley-GARDE MANGER
|
|
Violation:
A FOOD HANDLER WAS WEARING TWO RINGS ON ONE FINGER WHILE HANDLING FOOD.
|
|
Recommendation:
While preparing food, ensure that food employees do not wear jewelry on their arms and hands.
|
|
|
Item No.:
20
|
|
Site:
Galley-GARDE MANGER
|
|
Violation:
A GOUGE WAS NOTED IN THE HARD SEALANT ALONG THE BACK PLATE OF THE SLICER, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that multiuse food-contact surfaces are: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
28
|
|
Site:
Buffet-LIDO BUFFET
|
|
Violation:
A SMALL AMOUNT OF FOOD DEBRIS WAS NOTED IN A STORAGE CABINET WHERE CLEAN PLATES WERE BEING STORED.
|
|
Recommendation:
Ensure that cleaned equipment and utensils, laundered linens, and single-service and single-use articles are stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
|
|
|
Item No.:
33
|
|
Site:
Galley-HOT GALLEY
|
|
Violation:
LOOSE SOFT SEALANT WAS NOTED ALONG THE DECK UNDER THE CENTER HANDWASH SINK, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Repair or replace loose sealant.
|
|
|
Item No.:
24
|
|
Site:
Buffet-LIDO BUFFET
|
|
Violation:
THE SANITIZER SOLUTION IN THE WIPING CLOTH SANITIZER CONTAINER WAS BELOW 50 PPM.
|
|
Recommendation:
Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
|
|
|
Item No.:
16
|
|
Site:
Galley-HOT GALLEY
|
|
Violation:
POLENT TARTS WERE TESTED AT 44.4°F IN WALK-IN REFRIGERATOR 32. THE THERMOMETER IN THE UNIT NOTED 44°F. THE TARTS HAD BEEN PLACED IN THIS UNIT LESS THAN 1 HOUR PRIOR AND WERE REMOVED FOR BLAST CHILLING.
|
|
Recommendation:
Ensure refrigerated potentially hazardous foods are maintained below 41°F.
|
|
|
Item No.:
34
|
|
Site:
Galley-HOT GALLEY
|
|
Violation:
A LEAK WAS NOTED AT THE FAUCET OF THE HANDWASH SINK NEAR WALK-IN REFRIGERATOR 32.
|
|
Recommendation:
Repair potable water leak at the faucet of the handsink.
|
|
|
Item No.:
33
|
|
Site:
Galley-TRIDENT SNACK BAR
|
|
Violation:
THE SURFACE IN THE TECHNICAL COMPARTMENT BENEATH THE FOOD PREPARATION COUNTER WAS ROUGH, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Galley-HOT GALLEY
|
|
Violation:
A LOOSE PROFILE STRIP WAS NOTED ALONG THE LEFT SIDE OF THE DOORWAY OF WALK-IN REFRIGERATOR 30, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Replace the loose profile strip.
|
|
|
Item No.:
26
|
|
Site:
Galley-HOT GALLEY
|
|
Violation:
EXCESS WATER WAS NOTED IN THE MIXER COLLAR ADJACENT TO THE BLAST CHILLER.
|
|
Recommendation:
Remove excess water from the mixer collar.
|
|
|
Item No.:
33
|
|
Site:
Provisions-PROVISIONS CORRIDOR
|
|
Violation:
THE DECK WAS ROUGH MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
15
|
|
Site:
Provisions-DRY STORES
|
|
Violation:
A DAMAGED CAN OF MUSTARD HAD TABLE ALONG THE DAMAGED SEAL. THE CAN WAS REMOVED FOR DISCARD.
|
|
Recommendation:
Ensure that food packages are in good condition and protect the integrity of the contents so that the food is not exposed to adulteration or potential contaminants. Canned goods with dents on end or side seams may not be used.
|
|
|
Item No.:
33
|
|
Site:
Provisions-WINE STORES 4
|
|
Violation:
A LOOSE PROFILE STRIP WAS NOTED ALONG THE TOP OF THE DOORWAY, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
Repair the loose profile strip.
|
|
|
Item No.:
19
|
|
Site:
Provisions-PROVISIONS CORRIDOR
|
|
Violation:
TWO TORN BAGS OF FLOUR WERE NOTED IN THE CORRIDOR. THIS AREA WAS USED FOR STORAGE. PAPER DEBRIS WAS NOTED ON SEALED BAGS OF JASMINE RICE. THESE ISSUES WERE CORRECTED DURING THE INSPECTION.
|
|
Recommendation:
Ensure that food is protected from cross-contamination by: (4) Storing the food in packages, covered containers, or wrappings.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-SWIMMING POOL
|
|
Violation:
THE SWIMMING POOL LOGS DID NOT DOCUMENT WHEN THE CREW POOL WAS CLOSED. THE LOG WAS BLANK (NO ENTRIES) ON THE DAYS IN QUESTION.
|
|
Recommendation:
Ensure that entries are made in the swimming pool log when the pool is closed for maintenance or low halogen levels.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-
|
|
Violation:
THERE WAS NOT INDICATION THAT THE COLD SMOKED SALMON WAS PARASITE FREE OR FROZEN TO THE TIME AND TEMPERATURE REQUIRED FOR PARASITE DESTRUCTION.
|
|
Recommendation:
Before service in ready-to-eat form, ensure that raw, raw-marinated, partially cooked, or marinated-partially cooked fish other than molluscan shellfish: (1) Are frozen throughout to a temperature of -20°C (-4°F) or below for 168 hours (7 days) in a freezer; or -35°C (-31°F) or below for 15 hours in a blast freezer.
|
|
|
Item No.:
16
|
|
Site:
Galley-MESS AND GALLEY
|
|
Violation:
THE TIME CONTROL PLAN DID NOT INDICATE THAT THE FOODS IN THE GALLEY HOT STATION WERE ON TIME CONTROL. THE STAFF STATED THAT THE FOODS IN THIS STATION WERE ON TIME CONTROL. ALL OF THE FOODS TESTED WERE ABOVE 140°F.
|
|
Recommendation:
Amend the time control plan to reflect that foods in the galley hot station are on time control.
|
|
|
Item No.:
37
|
|
Site:
Galley-
|
|
Violation:
CONDENSATE WAS NOTED IN THE HOOD ABOVE THE FOODS IN THE HOT LINE. THE WATER WAS BOILING IN THIS UNIT.
|
|
Recommendation:
Ensure that containers of boiling water remain closed to prevent condensate collection above food items on the hot line.
|
|
|
Item No.:
36
|
|
Site:
Buffet-CREW MESS
|
|
Violation:
THE BULBS BEHIND THE SERVICE LINE WERE NOT SHIELDED OR SHATTER-RESISTANT.
|
|
Recommendation:
Install bulbs that are shieelded or shatter-resistant in this area.
|
|
|
Item No.:
36
|
|
Site:
Bar-GENERAL
|
|
Violation:
THE OVERHEAD BULBS WERE NOT ADEQUATELY SHIELDED AND WERE NOT SHATTER-RESISTANT.
|
|
Recommendation:
Ensure the overhead bulbs in this area are adequately shielded or are shatter-resistant.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-SWIMMING POOL
|
|
Violation:
THE VESSEL DOES HAVE DOCUMENTATION THAT THE POTABLE WATER TANKS HAVE BEEN INSPECTED, CLEANED AND DISINFECTED IN ACCORDANCE WITH THE VSP OPERATIONS MANUAL. THE WORK PROCEDURE FOR CLEANING AND DISINFECTING POTABLE WATER TANKS WAS ADEQUATE, HOWEVER, THERE WAS NO DOCUMENTATION THAT THESE TANKS WERE ACTUALLY DISINFECTED AT 50 PPM FOR 4 HOURS.
|
|
Recommendation:
Ensure that disinfection following potential contamination is accomplished by increasing free residual halogen to at least 50 mg/L (ppm) throughout the affected area and maintaining this concentration for 4 hours. Document that the potable water tanks were disinfected to the above mentioned criteria.
|
|
|
Item No.:
41
|
|
Site:
Children Area-
|
|
Violation:
THE PROCEDURE ON WHAT TO DO SHOULD A CHILD DEVELOP SYMPTOMS OF A COMMON INFECTIOUS CHILDHOOD DISEASE WHILE AT THE CENTER WAS INCOMPLETE. THE HOTEL DIRECTOR EXPLAINED THE DETAILED PROCEDURE VERBALLY.
|
|
Recommendation:
Completely document the procedures for the handling of children who develop symptoms of common childhood infectious diseases.
|
|
|
Item No.:
34
|
|
Site:
Galley-
|
|
Violation:
THE WATER WAS DRAINING VERY SLOWLY FROM THE HANDWASH SINK NEAR THE ENTRANCE TO THE GALLEY FROM THE CORRIDORL. THIS WAS WRITTEN DURING THE LAST INSPECTION.
|
|
Recommendation:
Ensure that a plumbing system in a food area is maintained in good repair.
|
|
|
Item No.:
30
|
|
Site:
Galley-TOILET ROOM
|
|
Violation:
TOILET TISSUE WAS NOT PROVIDED IN THE TOILET ROOM. THIS WAS WRITTEN DURING THE LAST INSPECTION.
|
|
Recommendation:
Ensure an adequate supply of toilet tissue is provided in the toilet room.
|
|
|
Item No.:
10
|
|
Site:
Recreational Water Facilities-SWIMMING POOL/WHIRLPOOL SPA
|
|
Violation:
A CORE SAMPLE WAS NOT USED FOR THE MONTHLY SEDIMENTATION TEST. THE DESCRIPTION OF THE TEST PROVIDED BY THE POOL/SPA OPERATOR INDICATED A GRAB SAMPLE WAS TAKEN INSTEAD OF THE REQUIRED CORE SAMPLE. THE CORRECT PROCEDURE WAS EXPLAINED TO THE POOL/SPA STAFF DURING THIS INSPECTION. THIS IS A REPEAT ITEM FROM THE PREVIOUS INSPECTION.
|
|
Recommendation:
Ensure that the granular filters are opened at least monthly and examined for cracks, mounds, or holes in the filter media and a core sample of the filter media is inspected for excessive organic material accumulation using a recommended sedimentation method.
|
|