Item No.:
33
|
|
Site:
Food Service General-GALLEY AND VERANDA LIDO
|
|
Violation:
THE PAINTED DECKING BENEATH COUNTERS AND LARGE EQUIPMENT PIECES WAS FRACTURING AND THE SURFACE WAS ROUGH, BROKEN, AND DIFFICULT TO CLEAN.
|
|
Recommendation:
Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
|
|
|
Item No.:
33
|
|
Site:
Galley-VERANDA - PORTSIDE GALLEY
|
|
Violation:
THE DECK/BULKHEAD JUNCTURE DIRECTLY BELOW THE COUNTER IN THE STARBOARD/AFT CORNER WAS SOILED WITH A SIGNIFICANT BLACK MOLD RESIDUE.
|
|
Recommendation:
Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
|
|
|
Item No.:
16
|
|
Site:
Food Service General-VERANDA - PANTRY AND OFFICERS MESS
|
|
Violation:
THE UNDERCOUNTER REACH-IN REFRIGERATORS LABELED DAY STORES/24 HOURS/45 °F HAD INDIVIDUAL PACKAGES OF YOGURT WITH NO MARKINGS OR LABELS INDICATING THE TIME AND DATE WHEN THEY SHOULD BE DISCARDED. THIS WAS CORRECTED DURING THE INSPECTION. THERE WAS ALSO AN UNLABELED CONTAINER OF SLICED CHEESE INSIDE THE OFFICERS MESS DAY STORE REFRIGERATOR.
|
|
Recommendation:
Ensure that refrigerated, ready-to-eat, potentially hazardous food is held at 7°C (45°F) up to 24 hours in existing short term holding refrigeration equipment provided: (1) The equipment is designated by a permanent label affixed to it indicating the maximum allowable product temperature is 7°C (45°F) and the maximum allowable storage time is 24 hours; (2) All containers of potentially hazardous foods placed in the unit must be labeled with a date and time by which food is to be used or discarded; (3) Potentially hazardous foods when placed in the equipment is to be at 5°C (41°F) or less; and (4) When the equipment is upgraded or replaced, it is to be with equipment that can maintain the potentially hazardous food at 5°C (41°F) or less.
|
|
|
Item No.:
36
|
|
Site:
Other-THE RESTAURANT DINING ROOM
|
|
Violation:
THE ARTIFICIAL LIGHT LEVEL AT ALL OF THE WAITER STATIONS WAS LESS THAN THE MINIMUM 220 LUX (20 FOOT CANDLES).
|
|
Recommendation:
Ensure that the light intensity is at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
|
|
|
Item No.:
17
|
|
Site:
Provisions-FISH FREEZER
|
|
Violation:
COLD-SMOKED SCOTTISH SALMON IS SERVED, BUT THERE WAS NO WRITTEN CERTIFICATION ON THE PACKAGING OR FROM THE SUPPLIER THAT THE FISH WAS FROZEN TO A TEMPERATURE AND TIME SUFFICIENT TO DESTROY PARASITES. THERE WAS ALSO NO ONBOARD RECORDS OF FREEZING TO PROVE THIS RESULT.
|
|
Recommendation:
Ensure that, if raw, raw-marinated, partially cooked, or marinated-partially cooked fish are served in ready-to-eat form: (1) The person in charge records the freezing temperature and time to which the fish are subjected and retains the records on the vessel for 90 calendar days beyond the time of service or sale of the fish; or (2) If the fish are frozen by a supplier, a written agreement or statement from the supplier stipulating that the fish supplied are frozen to a safe temperature and a time.
|
|
|
Item No.:
20
|
|
Site:
Galley-
|
|
Violation:
THE UNDERCOUNTER, TWO DOOR, REACH-IN REFRIGERATOR #13 WAS STILL OUT OF ORDER. THIS UNIT WAS POSTED OUT OF ORDER IN THE PREVIOUS INSPECTION OF 11 DECEMBER 2004 AND WAS REPORTEDLY 2 MONTHS OUT OF ORDER AT THAT TIME.
|
|
Recommendation:
Repair or replace this unit as soon as possible.
|
|
|
Item No.:
21
|
|
Site:
Galley-HOT GALLEY
|
|
Violation:
THE LEFT SIDE RANGE TOP WAS WARPED SEVERELY, RESULTING IN LARGE GAPS BETWEEN THE TOP AND THE FOUNDATION BELOW. THIS ITEM WAS ALSO NOTED ON THE INSPECTION CONDUCTED 11 DECEMBER 2004.
|
|
Recommendation:
Replace the warped range top.
|
|
|
Item No.:
40
|
|
Site:
Integrated Pest Management-INTEGRATED PEST MANAGEMENT (IPM)
|
|
Violation:
ALTHOUGH THE PEST MANAGEMENT PROGRAM IS WORKING WELL, THE IPM PLAN DESCRIBES ACTIVE MONITORING AND RECORDKEEPING IN A SIGHTING REPORT. IN FACT, THE FIRE WATCH MAKES NIGHTLY ACTIVE PEST MONITORING INSPECTIONS, BUT THERE WAS NO SPECIFIC SIGHTING REPORT FOUND.
|
|
Recommendation:
Update the IPM plan to reflect what is actuall happening on active monitoring inspections and include the log form for completion.
|
|
|
Item No.:
08
|
|
Site:
Potable Water-GARBAGE ROOM - DECK 2
|
|
Violation:
THE POTABLE WATER PIPE IN THE OVERHEAD WAS NOT BLUE STRIPED TO INDICATE POTABLE WATER.
|
|
Recommendation:
Ensure that potable water piping is painted light blue or striped with 15 cm (6 inches) light blue bands or a light blue stripe at fittings on each side of partitions, decks, and bulkheads and at intervals not to exceed 5 m (15 feet) in all spaces, except where the decor would be marred by such markings.
|
|
|
Item No.:
41
|
|
Site:
Ventilation-AIR-CONDITIONING FAN ROOMS
|
|
Violation:
THE CONDENSATE COLLECTION UNITS INSIDE THE 7 FAN ROOMS WERE DIFFICULT TO ACCESS FOR INSPECTION AND MAINTENANCE AND COULD NOT BE REVIEWED DURING THIS INSPECTION.
|
|
Recommendation:
Installation of sight inspection windows, doors with latches, or other visual means should be undertaken to ensure these collection pans can be easily accessed for inspection and maintenance.
|
|
|
Item No.:
*
|
|
Site:
Other-COMMENT
|
|
Violation:
OVERALL MANAGEMENT, OPERATION, AND RECORDKEEPING IN THE VARIOUS FOOD, HOTEL, AND WATER/TECHNICAL DEPARTMENTS WAS VERY GOOD.
|
|
Recommendation:
|
|