Cruise Ship: Seven Seas Navigator Cruise Line: Regent Seven Seas Inspection Date: 03/28/2005 Inspection Score: 95
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 08
Site: Potable Water-
Violation: THERE WERE MULTIPLE CONNECTION POINTS FOR HOSES AT BOTH THE FIRE MAIN AND SPRINKLER SYSTEM INTERNATIONAL SHORE CONNECTIONS. ONLY ONE FITTING ON EACH WAS PROTECTED WITH A REDUCED PRESSURE BACKFLOW PREVENTION DEVICE.
Recommendation: Place the reduced presssure backflow prevention device after all connections or install one device at each connection.
Item No.: 08
Site: Potable Water-
Violation: BLANK SPACES WERE NOTED IN THE PRODUCTION LOGS BETWEEN FREE CHLORINE RESIDUAL READINGS. THERE WAS NO INDICATION THAT PRODUCTION HAD STOPPED EVEN THOUGH THE LOG PROVIDED A SPACE FOR SUCH A NOTATION. IN ADDITION, SOME OF THE FREE CHLORINE READINGS DURING PRODUCTION WERE MORE THAN 4 HOURS APART.
Recommendation: Ensure that free residual halogen monitoring is performed at least hourly during the bunkering of potable water and performed at least once every 4 hours during the onboard production of potable water.
Item No.: 37
Site: Galley-MAIN GALLEY - SOUP KETTLE STATION
Violation: CONDENSATE WAS NOTED ABOVE THE OPEN TILTING PAN. WATER WAS BOILING IN THE OPEN TILTING PAN, POSSIBLY ACCOUNTING FOR THE CONDENSATE BUILD-UP.
Recommendation: Ensure that exhaust ventilation hood systems in food preparation and warewashing areas including components such as hoods, fans, guards, and ducting are designed to prevent grease or condensation from draining or dripping onto food, equipment, utensils, linens, and single-service and single-use articles.
Item No.: 08
Site: Potable Water-
Violation: THE POTABLE WATER LINES SUPPLYING THE SINK IN THE ENGINE WORKSHOP, AND MAIN LAUNDRY SINK WERE NOT STRIPED BLUE.
Recommendation: Ensure that potable water piping is painted light blue or striped with 15 cm (6 inches) light blue bands or a light blue stripe at fittings on each side of partitions, decks, and bulkheads and at intervals not to exceed 5 m (15 feet) in all spaces, except where the decor would be marred by such markings.
Item No.: 33
Site: Galley-MAIN GALLEY - SOUP KETTLE STATION
Violation: LOOSE SEALANT WAS NOTED IN THE VENTILATION HOOD ABOVE THE TILTING PAN.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 08
Site: Potable Water-
Violation: THE AIR GAP PROVIDED AT THE LAUNDRY TANK, IN THE MAIN LAUNDRY, WAS NOT TWO TIMES THE DIAMETER OF THE SUPPLY LINE.
Recommendation: Ensure that air gaps are at least twice the diameter of the delivery fixture opening and a minimum of 3 cm (1 inch).
Item No.: 08
Site: Potable Water-
Violation: THE SAMPLE POINT FOR TANK FW 4C DID NOT POINT DOWN.
Recommendation: Ensure that potable water tanks have sample valves which are turned down.
Item No.: 08
Site: Potable Water-
Violation: THERE WAS NO INDICATION FROM THE MAINTENANCE AND CLEANING RECORDS THAT THE POTABLE WATER TANKS WERE ADEQUATELY FLUSHED PRIOR TO BEING PUT BACK IN TO SERVICE.
Recommendation: Ensure that potable water tanks are inspected, cleaned, and disinfected during dry docks and wet docks, or every 2 years, whichever is less. Ensure that the disinfected parts of the system are flushed with potable water until the free residual halogen is 5.00 mg/L (ppm). Ensure that the documentation of the cleaning is maintained for 12 months and is available to the VSP for review during inspections.
Item No.: 21
Site: Galley-MAIN GALLEY - HOT LINE
Violation: THE PROTECTIVE COVER WAS MISSING FROM THE MOUNTED THERMOMETER ON THE BAIN MARIE, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 08
Site: Potable Water-
Violation: THERE WERE NUMEROUS READINGS OF 2.2 PPM FOR THE PRODUCED WATER. WHEN QUESTIONED THE ENGINEER INDICATED THAT THE READINGS MAY HAVE COME FROM THE ANALYZER WHICH HAD A SET POINT OF 2.2 PPM. THERE WERE NOT RECORDS TO INDICATED THAT THE ANALYZER WAS CALIBRATED PRIOR TO THE START OF BUNKERING OR PRODUCTION.
Recommendation: Ensure that halogen analyzer-chart recorders used in lieu of manual tests and logs are calibrated at the beginning of bunkering or production, and the calibration is recorded on the chart or in a log book.
Item No.: 33
Site: Galley-MAIN GALLEY - HOT LINE
Violation: LOOSE SEALANT WAS NOTED IN THE VENTILATION HOOD ABOVE THE GRILLS.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 10
Site: Other-WHIRLPOOLS
Violation: A CORE SAMPLE WAS NOT USED FOR THE MONTHLY SEDIMENTATION TESTS.
Recommendation: Ensure that the granular filters are opened at least monthly and examined for cracks, mounds, or holes in the filter media and a core sample of the filter media is inspected for excessive organic material accumulation using a recommended sedimentation method.
Item No.: 41
Site: Ventilation-
Violation: THE CONDENSATE DRAIN PANS WERE NOT ACCESSIBLE FOR INSPECTION.
Recommendation: Ensure that air handling unit condensate drain pans and collection systems are accessible for inspection, maintenance, and cleaning.
Item No.: 21
Site: Galley-MAIN GALLEY - ROOM SERVICE PANTRY
Violation: A CONTROL KNOB WAS MISSING ON THE CAPPUCCINO MACHINE, LEAVING AN OPENING, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 10
Site: Other-SWIMMING POOL AND WHIRLPOOLS
Violation: THE FECAL ACCIDENT PROCEDURE DID NOT TAKE IN TO ACCOUNT LOOSE STOOLS AND THE NEED TO INACTIVATE CRYPTOSPORIDIUM.
Recommendation: Ensure that the fecal accident procedure takes in to account loose stools and the need to inactivate cryptosporidium.
Item No.: 34
Site: Galley-MAIN GALLEY - ROOM SERVICE PANTRY
Violation: THE DRAIN WAS CLOGGED, RESULTING IN STANDING WATER ON THE DECK.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 10
Site: Other-WHIRLPOOLS
Violation: THE DRAIN COVERS FOR THE WHIRLPOOLS WERE NOT ANTI-VORTEX, ANTI-ENTRAPMENT, BY DESIGN.
Recommendation: Ensure that anti-vortex drain covers are provided on swimming pools and whirlpool spas.
Item No.: 10
Site: Other-WHIRLPOOLS
Violation: THE STANDARD PRECAUTIONS AND RISKS SIGN FOR THE WHIRLPOOLS WAS POSTED ON THE BULKHEAD UNDER THE STAIRWAY AND WAS NOT NEAR THE WHIRLPOOLS
Recommendation: Ensure that a sign is installed near the whirlpool spas that lists standard safety precautions and risks, warning against use by particularly susceptible people, such as those who are immunocompromised.
Item No.: 29
Site: Galley-PORTOFINO
Violation: A TROLLEY WAS STAGED IN FRONT OF THE HANDWASH SINK.
Recommendation: Ensure that handwashing facilities are used for no other purpose and are accessible at all times.
Item No.: 28
Site: Galley-PORTOFINO DISHWASH/GLASSWASH
Violation: THE CLEAN RAMP OF THE DISHWASH UNIT WAS SOILED WITH FOOD DEBRIS.
Recommendation: Ensure that warewashing machines; the compartments of sinks, basins, or other receptacles used for washing and rinsing equipment, utensils, or raw foods, or laundering wiping cloths; and drainboards are cleaned: (1) Before use; (2) Throughout the day at a frequency necessary to prevent recontamination of equipment and utensils and to ensure that the equipment performs its intended function; and (3) If used, at least every 24 hours.
Item No.: 38
Site: Galley-PORTOFINO DISHWASH/GLASSWASH
Violation: A "WASH HANDS OFTEN" SIGN WAS NOT POSTED OVER THE HANDWASH SINK.
Recommendation: Ensure that a sign stating "WASH HANDS OFTEN" in a language that the food employees understand is posted over handwashing sinks.
Item No.: 20
Site: Galley-PORTOFINO
Violation: SLOTTED FASTENERS WERE NOTED IN THE ICE/WATER CONTACT SURFACES OF THE UPPER COMPARTMENT OF THE ICE MACHINE, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Item No.: 36
Site: Buffet-PORTOFINO
Violation: THE LIGHT BULBS AT THE INFRARED LAMPS WERE NOT SHATTER-RESISTANT AND PROTRUDED FROM THE METAL SLEEVES.
Recommendation: Ensure that an infrared or other heat lamp is protected against breakage by a shield surrounding and extending beyond the bulb so that only the face of the bulb is exposed.
Item No.: 19
Site: Buffet-PORTOFINO
Violation: A SNEEZE SHIELD WAS NOT PROVIDED AT THE FISH CARVING STATION. FRUITS SUCH AS GRAPES, APPLES, PEACHES, AND NECTARINES WERE NOT PLACED UNDER A SNEEZE SHIELD.
Recommendation: Ensure that food on display is protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
Item No.: 24
Site: Galley-MAIN GALLEY - DISHWASH AREA
Violation: THE MEASURED FINAL RINSE TEMPERATURE ON THE FLIGHT TYPE DISHWASHER WAS AT 140° F DURING MULTIPLE THE MOUNTED FINAL RINSE THERMOMETER DISPLAYED 140° F AS WELL. THE MOUNTED PRESSURE GAUGE DISPLAYED A READING OF 0.6 BAR. THE LAST TIME THE CREW RECORDED MANUAL FINAL RINSE TEMPERATURE READINGS WAS AT 0700. THE TESTS CONDUCTED BY THE INSPECTOR WAS AT 1030. ACCORDING TO GALLEY PERSONNEL, IT APPEARS THAT A DROP IN PRESSURE MAY HAVE RESULTED IN THE LOW FINAL RINSE TEMPERATURE MEASUREMENTS. THE MACHINE WAS IN ACTIVE USE AT THE TIME OF THE INSPECTION.
Recommendation: In a mechanical operation, ensure that the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F), or less than: (1) For a stationary rack, single temperature machine, 74°C (165°F); or (2) For all other machines, 82°C (180°F); or (3) A utensil surface temperature of 71°C (160°F) as measured by an irreversible registering temperature indicator shall be achieved. (4) The maximum temperature of 90°C (194°F), does not apply to the high pressure and temperature systems with wand-type, hand-held, spraying devices used for the in-place cleaning and sanitizing of equipment such as meat saws.
Item No.: 36
Site: Buffet-PORTOFINO BUFFET SERVICE SIDE
Violation: INADEQUATE LIGHTING WAS NOTED ALONG THE WORKING AREA OF THE SERVICE SIDE OF THE BUFFET.
Recommendation: Ensure that the light intensity is at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 33
Site: Buffet-PORTOFINO BUFFET SERVICE SIDE
Violation: THE BULKHEAD-DECK JUNCTURE WAS NOT ADEQUATELY COVED, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that bulkhead and deck junctures are coved.
Item No.: 24
Site: Galley-MAIN GALLEY - POT WASH AREA
Violation: THE FINAL RINSE TEMPERATURE MEASURED 144° F ON THREE SEPARATE POT WASH CYCLES. THE MACHINE WAS IN ACTIVE USE AT THE TIME OF THE INSPECTION.
Recommendation: In a mechanical operation, ensure that the temperature of the fresh hot water sanitizing rinse as it enters the manifold is not more than 90°C (194°F), or less than: (1) For a stationary rack, single temperature machine, 74°C (165°F); or (2) For all other machines, 82°C (180°F); or (3) A utensil surface temperature of 71°C (160°F) as measured by an irreversible registering temperature indicator shall be achieved. (4) The maximum temperature of 90°C (194°F), does not apply to the high pressure and temperature systems with wand-type, hand-held, spraying devices used for the in-place cleaning and sanitizing of equipment such as meat saws.
Item No.: 20
Site: Buffet-PORTOFINO COFFEE STATION
Violation: THE SILVER FINISH WAS WORN INSIDE THE WATER PITCHER, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Item No.: 21
Site: Buffet-PORTOFINO COFFEE STATION
Violation: A THERMOMETER WAS NOT PROVIDED INSIDE THE REFRIGERATOR SECTION OF THE COFFEE MACHINE.
Recommendation: Ensure that cold or hot holding equipment used for potentially hazardous food is designed to include and is equipped with at least one integral or affixed temperature measuring device that is located to allow easy viewing of the device's temperature display.
Item No.: 33
Site: Galley-MAIN GALLEY - POT WASH AREA
Violation: CRACKED DECK TILES AND EXCESS GROUT WAS NOTED IN THIS AREA.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Buffet-PORTOFINO DINING ROOM-BUFFET LOCKER
Violation: ITEMS WERE STORED DIRECTLY ON THE DECK, MAKING CLEANING OF THE DECK DIFFICULT. THIS LOCKER WAS NOT PROPERLY FINISHED FOR STORAGE. THE BULKHEADS WERE NOT FINISHED TO BE DURABLE AND EASY TO CLEAN.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 31
Site: Buffet-PORTOFINO DINING ROOM-BUFFET LOCKER
Violation: CHEMICAL SANITIZERS AND FUEL CANS WERE STORED WITH FOOD ITEMS AND CLEAN WATER PITCHERS.
Recommendation: Ensure that poisonous or toxic materials used in food area cleaning and maintenance are stored so they cannot contaminate food, equipment, utensils, linens, and single-service and single-use articles by separating the poisonous or toxic materials by storing in a cleaning materials locker.
Item No.: 37
Site: Galley-MAIN GALLEY - POT WASH AREA
Violation: CONDENSATE WAS NOTED INSIDE THE LIGHT FIXTURE IN FRONT OF THE POT WASH. THERE WAS AN OPENING AT ONE END OF THE FLUORESCENT LIGHT FIXTURE.
Recommendation: Ensure that all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item No.: 15
Site: Galley-CREW GALLEY
Violation: A CAN OF APRICOT HALVES WAS NOTED DENTED ALONG THE TOP SEAM. THIS ITEM WAS DISPOSED OF DURING THE INSPECTION.
Recommendation: Ensure that food packages are in good condition and protect the integrity of the contents so that the food is not exposed to adulteration or potential contaminants. Canned goods with dents on end or side seams may not be used.
Item No.: 19
Site: Pantry-ROOM SERVICE PANTRIES
Violation: GARBAGE CANS WERE STAGED DIRECTLY IN FRONT OF STORAGE RACKS OF CANNED SODA.
Recommendation: Ensure that food is protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 16
Site: Galley-CREW GALLEY
Violation: A PAN OF HARD BOILED EGGS WAS MEASURED BETWEEN 48-50° F. THESE ITEMS WERE REMOVED FOR QUICK CHILLING.
Recommendation: Ensure that potentially hazardous food is maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above, or (2) At 5°C (41°F) or less.
Item No.: 28
Site: Pantry-GALLELEO
Violation: CLEANED URNS WERE NOT STORED INVERTED TO DRAIN. WATER WAS NOTED IN THESE UNITS.
Recommendation: After cleaning and sanitizing, ensure that equipment and utensils are air-dried or adequately drained before contact with food. Ensure that clean equipment and utensils are stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 26
Site: Pantry-GALLELEO
Violation: THE NOZZLES OF THE URNS WERE NOT DISASSEMBLED DURING CLEANING. THE NOZZLES WERE HEAVILY ENCRUSTED WITH RESIDUE.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 33
Site: Galley-CREW GALLEY - HOT GALLEY
Violation: THE PAINT IN THE SCUPPER WELLS IN FRONT OF THE TILTING PANS AND STEAM KETTLE WAS FAILING, LEAVING A ROUGHENED SURFACE, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 36
Site: Bar-NAVIGATOR LOUNGE
Violation: SOME OF THE LIGHT FIXTURES WERE OUT OF ORDER AND NOT FITTED WITH LIGHTBULBS. INADEQUATE LIGHTING WAS NOTED IN THIS AREA.
Recommendation: Ensure that the light intensity is at least 220 Lux (20 foot candles) on food preparation surfaces, and at a distance of 75 centimeters (30 inches) above the deck in food preparation areas, handwashing facilities, warewashing areas, equipment, and utensil storage, pantries, toilet rooms, and consumer self-service areas.
Item No.: 33
Site: Bar-NAVIGATOR LOUNGE
Violation: STAGNANT WATER WAS NOTED IN THE TECHNICAL COMPARTMENT UNDER THE SPEED RACK.
Recommendation: Ensure that decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, are cleaned as often as necessary.
Item No.: 33
Site: Provisions-PROVISIONS - FISH PREPARATION
Violation: LOOSE DECK TILES AND RECESSED GROUT WAS NOTED AT THE THRESHOLD OF FISH THAW WALK-IN UNIT #7.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Food Service General-BARS AND PORTOFINO
Violation: SOME OF THE TECHNICAL SPACES UNDER THE COUNTERS HAD ROUGH SURFACES THAT WERE DIFFICULT TO CLEAN.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 33
Site: Food Service General-FOOD SERVICE GENERAL
Violation: EXCESS GROUT WAS NOTED ON DECK TILES IN SEVERAL FOOD PREPARATION AND FOOD STORAGE AREAS.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.