Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Costa Mediterranea Cruise Line: Costa Crociere S.P.A. Inspection Date: 03/29/2005 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 21
Site: Galley-SAUCE STATION
Violation: THE LABELS WERE PEELING FROM THE SIDES OF THE CONTROL PANELS FOR THE KETTLES, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 21
Site: Galley-HOT GALLEY
Violation: THE LABEL WAS PEELING FROM THE GROOVED GRILL, PB00115, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 20
Site: Food Service General-
Violation: SLOTTED FASTENERS WERE NOTED IN THE FOOD CONTACT AREAS OF THE FRYERS, ,MAINLY ON THE TEMPERATURE PROBE MOUNTS, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
Item No.: 26
Site: Galley-POTWASH
Violation: SEVERAL SOILED PANS WERE STORED AS CLEAN IN THE STORAGE RACKS.
Recommendation: Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 33
Site: Galley-VEGETABLE SECTION
Violation: A LOOSE BULKHEAD PANEL WAS NOTED BEHIND OVEN 4811.011.055, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 21
Site: Galley-VEGETABLE SECTION
Violation: THE LABELS WERE PEELING FROM THE SIDES OF THE KETTLE CONTROL PANEL, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 20
Site: Galley-DECK 2 COFFEE PANTRY
Violation: THE BULK MILK DISPENSING TUBES WERE 2 1/2-3 INCHES LONG.
Recommendation: Ensure that the bulk milk container dispensing tube is cut on the diagonal leaving no more than 3 centimeters (1 inch) protruding from the chilled dispensing head.
Item No.: 28
Site: Galley-DISHWASH CLEAN STORAGE AREA
Violation: THE PLATES IN THE TROLLEY WERE NOT STORED COVERED OR INVERTED.
Recommendation: Ensure that clean equipment and utensils are stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 30
Site: Galley-TOILET ROOM
Violation: TOILET TISSUE WAS NOT PROVIDED IN THE TOILET ROOM.
Recommendation: Ensure that a supply of toilet tissue is provided at each toilet at all times.
Item No.: 37
Site: Galley-TOILET ROOM
Violation: THIS AREA WAS VERY HOT AND DID NOT HAVE ADEQUATE VENTILATION.
Recommendation: Ensure that all food preparation, warewashing, and toilet rooms have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item No.: 26
Site: Galley-POTWASH
Violation: TWO PANS WERE SOILED AND STORED AS CLEAN.
Recommendation: Ensure that food-contact surfaces of equipment and utensils are clean to sight and touch.
Item No.: 21
Site: Galley-
Violation: THE LABEL WAS PEELING FROM THE SIDE OF THE KETTLE CONTROL PANEL, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 34
Site: Buffet-STAFF MESS
Violation: THE HANDWASH SINK WAS OUT OF ORDER.
Recommendation: Ensure that a plumbing system in a food area is maintained in good repair.
Item No.: 21
Site: Provisions-
Violation: WOODEN PALLETS WERE NOTED IN THE LIQUOR STORE AND WATER STORE. THESE PALLETS WERE POROUS, MAKING CLEANING DIFFICULT.
Recommendation: Ensure that nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning are constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 16
Site: Food Service General-
Violation: THERE WAS NO INDICATION THAT THE COLD SMOKED SALMON WAS CERTIFIED PARASITE FREE OR FROZEN TO THE TIME AND TEMPERATURE REQUIRED FOR PARASITE DESTRUCTION.
Recommendation: Before service in ready-to-eat form, ensure that raw, raw-marinated, partially cooked, or marinated-partially cooked fish other than molluscan shellfish: (1) Are frozen throughout to a temperature of -20°C (-4°F) or below for 168 hours (7 days) in a freezer; or -35°C (-31°F) or below for 15 hours in a blast freezer.
Item No.: 20
Site: Room Service-DECK 6 PANTRY
Violation: THE BULK MILK DISPENSING TUBE WAS 2 INCHES LONG AND WAS NOT CUT AT AN ANGLE. THIS WAS CORRECTED DURING THE INSPECTION.
Recommendation: Ensure that the bulk milk container dispensing tube is cut on the diagonal leaving no more than 3 centimeters (1 inch) protruding from the chilled dispensing head.
Item No.: 41
Site: Children Area-
Violation: THE PROCEDURE ON WHAT TO DO SHOULD A CHILD DEVELOP SYMPTOMS OF A COMMON INFECTIOUS CHILDHOOD DISEASE WAS EXPLAINED VERBALLY BUT WAS NOT FULLY DETAILED IN WRITING.
Recommendation: Ensure that the child-activity center has a written policy on procedures to be followed when a child develops symptoms of an infectious illness while at the center.
Item No.: 02
Site: Medical-
Violation: NEW CREWMEMBERS ARE NOT CURRENTLY QUESTIONED ABOUT SYMPTOMS OF GASTROINTESTINAL ILLNESS DURING THE 72 HOURS PRIOR TO BOARDING THE VESSEL.
Recommendation: Ensure that the reportable cases includes those crew members with a symptom onset time of up to 3 days before boarding the vessel.
Item No.: 24
Site: Buffet-LIDO MAIN LINE CENTER BUFFET
Violation: THE CHLORINE CONCENTRATION WAS MEASURED AT LESS THAN 50 PPM IN A SANITIZE BUCKET. THE CHLORINE CONCENTRATION WAS MEASURED AT GREATER THAN 200 PPM IN A SANITIZE BUCKET.
Recommendation: Ensure that a chlorine solution used as a sanitizing solution has a concentration between 50 mg/L (ppm) and 200 mg/L (ppm).
Item No.: 27
Site: Buffet-LIDO MAIN LINE
Violation: A SMALL AMOUNT OF FOOD DEBRIS WAS FOUND IN THE PLATE SPIDER.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Buffet-LIDO COFFEE STATION - PIZZERIA
Violation: A PREVIOUSLY CLEANED PLATE SPIDER WAS SOILED.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 26
Site: Galley-LIDO DISHWASH AREA
Violation: A FEW PREVIOUSLY CLEANED EATING UTENSILS WERE FOUND SOILED AND STORED AS CLEAN.
Recommendation: Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 27
Site: Buffet-LIDO BACK LINE (RIGHT)
Violation: THE UNDERCOUNTER CABINET WAS SOILED.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 27
Site: Buffet-LIDO BACK LINE (RIGHT)
Violation: THE PREVIOUSLY CLEANED PLATE SPIDER CABINET WAS SOILED.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 26
Site: Galley-LIDO POOLSIDE GRILL
Violation: STANDING WATER WAS NOTED INSIDE THE UNDERCOUNTER REFRIGERATOR.
Recommendation: Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 20
Site: Galley-LIDO CENTER GRILL
Violation: THE HEATING COIL TO THE DEEP FAT FRYER WAS CORRODED AND PITTED MAKING CLEANING DIFFICULT.
Recommendation: Ensure that materials used in the construction of multiuse utensils and food-contact surfaces of equipment are: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program