Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Club Med 2 Cruise Line: Club Med Marine Inspection Date: 03/21/2005 Inspection Score: 92
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 40
Site: Integrated Pest Management-PLAN DEVELOPMENT
Violation: THE WRITTEN INTEGRATED PEST MANAGEMENT PLAN IS INCOMPLETE, IN THAT IT DOES NOT DESCRIBE CONDUCTING INSPECTIONS FOR PESTS DURING PROVISIONING OF FOOD AND SUPPLIES, IT DOES NOT ESTABLISH ANY ACTIVE MONITORING FOR LIVE PESTS IN THE OPERATIONAL AREAS OF THE SHIP, AND IT DOES NOT SPECIFY THAT SOME OF THOSE INSPECTIONS SHOULD BE CONDUCTED AT NIGHT.
Recommendation: Update the IPM plan to require active inspections for pests during provisioning and active monitoring inspections for live pests, including some night inspections.
Item No.: 07
Site: Potable Water-ENGINE ROOM REVERSE OSMOSIS MINERALIZER UNIT
Violation: THE DRAIN PIPE FOR THE MINERALIZER HAD A TUBE ATTACHED WHICH EXTENDED THE LINE BELOW THE DECK GRATING. WHEN THE HOSE WAS TRACED IT WAS SUBMERGED IN STAGNANT, FILTHY WASTEWATER IN THE BILGE. THE HOSE WAS REMOVED IMMEDIATELY, RESTORING THE AIR-GAP FOR THE MINERALIZER DRAIN.
Recommendation: Include air-gap (non-technical) backflow prevention points in the ship"s summary of devices and ensure they are inspected as other devices are inspected to determine that the gap still exists and is in good condition.
Item No.: 08
Site: Potable Water-POTABLE WATER TANKS
Violation: THE WRITTEN AND ELECTRONIC RECORDS OF THE POTABLE WATER TANK CLEANING AND DISINFECTION WAS NOT SPECIFIC ABOUT THE HALOGEN USED TO DISINFECT, THE CONCENTRATION AND CONTACT TIME USED, AND THERE WAS NO DESCRIPTION OF THE PROCESS OF REMOVING THE DISINFECTANT BY FLUSHING OR OTHER MEANS PRIOR TO REFILLING THE TANK WITH POTABLE WATER AGAIN. THE WRITTEN TANK DISINFECTION PROCEDURE WAS EQUALLY LACKING IN DETAIL ABOUT WHAT IS DONE.
Recommendation: Ensure that the disinfected parts of the system are flushed with potable water until the free residual halogen is 5.00 mg/L (ppm).
Item No.: 06
Site: Potable Water-POTABLE WATER DISTRIBUTION SYSTEM
Violation: THE POTABLE WATER DISTRIBUTION HALOGENATION MONITORING CHARTS HAD NO NOTATIONS OF CALIBRATION OR CALIBRATION CHECKS, AND THERE WAS NO SEPARATE LOG WHERE THIS INFORMATION WAS RECORDED.
Recommendation: Ensure that the halogen analyzer-chart recorder is properly maintained, operated, and calibrated daily in accordance with the manufacturer's instructions.
Item No.: 28
Site: Galley-GRAND BLEU DISHWASH
Violation: THERE WERE 3 CLEAN DISHWARE RACKS SET ON EDGE IN CONTACT WITH THE DECK BENEATH THE CONVEYOR DISHWASHER AT THE PULPER TROUGH. ANOTHER 4 CLEAN DISHWARE RACKS WERE STACKED ON THE DECK AT THE END OF THE DISHWASHER CLEAN LANDING TABLE.
Recommendation: Provide and use deck stands to stage disware racks for use in the dishwash machines.
Item No.: 21
Site: Galley-GRAND BLEU HOT GALLEY
Violation: THE TECHNICAL COMPARTMENT OF THE DOUBLE DEEP FRYERS HAD GAPS AND SEAMS PRESENT WHICH MADE CLEANING DIFFICULT. THESE AREAS ARE SUBJECT TO OIL SPLASH AND COLLECTION. ADDITIONALLY, THE ADJACENT GRILL HAD DIFFICULT TO CLEAN SEAMS AT THE SLIDE ATTACHMENT FOR THE GREASE PAN AND AT THE GREASE DRAIN OPENING.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Galley-GRAND BLEU HOT GALLEY
Violation: THE SEAMS AND THE DOOR HINGES IN THE TECHNICAL CABINET BELOW THE DOUBLE DEEP FRYERS WERE HEAVILY SOILED WITH ACCUMULATED GREASE DEBRIS. THE SEAM AT THE GROOVE FOR THE GRILL GREASE PAN, THE UNDERSIDE OF THE GRILL, AND THE DRAIN OPENING WERE ALL SOILED WITH GREASE DEBRIS.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Galley-DISTRIBUTION GALLEY - DECK E
Violation: THERE WERE DIFFICULT TO CLEAN SEAMS ALONG THE TECHNICAL CABINET BELOW THE DEEP FRYER. THE SEAMS ALONG THE GRILL GREASE PAN INSERT SLIDE AND THE DRAIN FOR THE PAN WERE ALSO DIFFICULT TO CLEAN.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 21
Site: Galley-HOT GALLEY - DECK D
Violation: THE LOWER STACK OVEN WAS POSTED OUT OF ORDER AND REPORTEDLY HAS NOT BEEN USED FOR A YEAR.
Recommendation: Remove or replace this oven if it cannot be repaired.
Item No.: 16
Site: Food Service General-TIME ONLY AS A PUBLIC HEALTH CONTROL
Violation: THE WRITTEN TIME ONLY AS A PUBLIC HEALTH CONTROL PLAN IS INCOMPLETE IN THAT IT IS ONLY SPECIFIC TO COLD FOODS (WHICH ARE NOT LISTED) AND DOES NOT DESCRIBE SERVICE TIME PERIODS. ADDITIONALLY, THE PLAN SPECIFIES THAT COLD FOODS HELD ONLY UNDER TIME CONTROL CAN BE HELD FOR AN ADDITIONAL 24 HOURS FOR SERVICE IF THEY HAVE NOT BEEN MOVED FROM A HOLDING UNIT TO A BUFFET LINE. THE COLD HOLDING WHERE THESE COLD ITEMS WERE HELD WERE SAID TO BE ON TIME ONLY. LARGE PANS OF HOT CHICKEN AND MEAT STEWS WERE HELD IN BACK-UP HOT HOLDING UNITS, SAID TO BE ON TIME. THE LABELS ON THE PANS HAD 7:00 PM WRITTEN ON THEM, BUT THE TIME OF THE INSPECTION WAS 11:00 AM. ALL THE FOODS WERE AT TEMPERATURES OVER 145 °F.
Recommendation: Modify the time as a public health control plan so that it accurately reflects which foods are involved, where foods are stored on temperature control, when those foods so under time control, and the service periods involved for each service area (breakfast, lunch, and dinner). Ensure that time labels are applied only when time control begins and that the labels don"t exceed 4 hours.
Item No.: 21
Site: Galley-HOT GALLEY - DECK D
Violation: THE GAPS BETWEEN THE RANGE TOPS WERE DIFFICULT TO CLEAN.
Recommendation: Ensure that nonfood-contact surfaces are free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Galley-HOT GALLEY - DECK D
Violation: THERE WAS FOOD AND GREASE DEBRIS PRESENT IN THE GAPS BETWEEN THE RANGE TOPS. THIS WAS ALSO NOTED IN THE JANUARY 2005 INSPECTION.
Recommendation: Ensure that nonfood-contact surfaces of equipment are kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Galley-HOT GALLEY - DECK D
Violation: THE DECK TRIM BENEATH THE END RANGE ON THE PORT AFT SECTION WAS HEAVILY SOILED WITH A BLACK MOLD RESIDUE.
Recommendation: Steam clean if necessary to remove the mold residue on the deck trim.
Item No.: 33
Site: Galley-HOT GALLEY AND DISHWASH - DECK D
Violation: THE DECKS IN THE HOT SECTION AND DISHWASH HAD CRACKED OR BROKEN DECK TILES, ESPECIALLY NEAR THE DECK GUTTERS.
Recommendation: Ensure that decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas are constructed and maintained for easy cleaning.
Item No.: 21
Site: Galley-BAKERY/PASTRY
Violation: THE PASTRY FOLDER MACHINE WAS WRAPPED WITH PLASTIC AND POSTED OUT OF ORDER. STAFF STATED IT WAS OUT OF ORDER FOR OVER 2 MONTHS.
Recommendation: Repair or replace this unit. If it will not be used it should be discarded.
Item No.: 20
Site: Galley-POT WASH
Violation: ONE OF THE THIN BROWN CUTTING BOARDS ON THE POT WASH CLEAN STORAGE RACK WAS DIFFICULT TO CLEAN DUE TO THE AREAS OF DEEP CUTS IN THE BOARD.
Recommendation: Replace the cutting board.
Item No.: 26
Site: Buffet-CREW MESS
Violation: A FEW OF THE UTENSILS IN THE CLEAN BASKET AT THE BUFFET COUNTER WERE SOILED WITH FOOD DEBRIS. TWO OF THE UTENSIL STORAGE BASKETS HAD LOOSE FOOD DEBRIS STUCK INSIDE WHERE UTENSILS WERE CONTACTING THE FOOD DEBRIS.
Recommendation: Ensure that food only contacts surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 20
Site: Buffet-CREW MESS
Violation: A CONTAINER OF INDIVIDUAL PACKAGED CHEESE TRIANGLES WAS SET ON TOP OF THE COLD TOP BUFFET. ONLY THE BOTTOM SURFACE OF THIS PLASTIC CONTAINER CONTACTED THE BUFFET AND SOME LOOSE ICE PIECES SURROUNDING THE BASE. THE INTERNAL TEMPERATURE OF THE CHEESE WAS 48 °F. ALTHOUGH NOT DESIGNATED ON THE TIME AS A PUBLIC HEALTH CONTROL PLAN, BOTH THIS CHEESE AND THE ADJACENT PACKAGED YOGURT WERE SAID TO BE ON TEMPERATURE CONTROL FOR THIS BUFFET. THE YOGURT WAS AT A PROPER TEMPERATURE.
Recommendation: Either the package cheese could be added to the time only as a control plan or they could be arranged on drained ice or the cold top surface to ensure proper temperature control.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program