|
|
|
Item No.:
29
|
|
Site:
Other-VERANDAH CAFE
|
|
Violation:
No deficiencies were noted with regards to the potable water system.
|
|
Recommendation:
|
|
|
Item No.:
10
|
|
Site:
Other-VERANDAH CAFE
|
|
Violation:
The light fixtures over the grill and the grill were soiled with grease.
|
|
Recommendation:
Non-food contact surfaces of equipment should be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
|
|
|
Item No.:
39
|
|
Site:
Other-VERANDAH CAFE
|
|
Violation:
One large section of pre-cooked turkey was stored in a pan with other ready-to-eat luncheon meats. While the other meats were less than 45oF., the turkey was found to be 52oF. This product had reportedly been under refrigeration about 10-12 hours.
|
|
Recommendation:
Potentially hazardous food requiring refrigeration after preparation should be rapidly cooled to an internal temperature of 45oF or below. Since any temperature between 45oF and 140oF presents a hazard to public health in terms of microbial growth, food must remain in the critical temperature zone for as little time as possible.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Levels of light were found to be less than 20-footcandles in several areas of the Verandah Cafe and the Bar Pantry.
|
|
Recommendation:
It is recommended that additional lighting be provided to insure at least 20-footcandles of light on all food preparation surfaces.
|
|
|
Item No.:
29
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Several previously washed cooking pans were soiled with food residue. Also, many metal plate covers were greasy and had food residue adhering to them.
|
|
Recommendation:
All food preparation equipment, utensils, tableware, other food contact surfaces, and food storage containers shall be washed, rinsed, and sanitized after every use or change in use. A food surface is that surface of equipment or utensil with which food normally comes in contact and those surfaces from which food may drip, drain, or splash back onto other surfaces normally in contact with food.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The interior door surface of the main dishwashing machine had a heavy build-up of food residue adhering to it.
|
|
Recommendation:
Non-food contact surfaces of equipment should be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The slicer had some food residue adhering to it.
|
|
Recommendation:
To prevent cross-contamination, kitchenware and food contact surfaces of equipment should be washed, rinsed and sanitized after each use.
|
|
|
Item No.:
29
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Open seams were present in the exhaust hoods over the ranges and grills and also on the support brackets for the flat trays under the hood filters.
|
|
Recommendation:
Nonfood preparation equipment must be easily cleanable, in good repair, and corrosion-resistant. It should be constructed in accordance with criteria outlined in the Food Service Equipment Standards of the National Sanitation Foundation.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Grease and food residue were present in the open seams listed on the previous item.
|
|
Recommendation:
Non-food contact surfaces of equipment should be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The tilting skillet lid had split and torn metal and an open seam existed in the area of the handle.
|
|
Recommendation:
Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, should be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and should be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
|
|
|
Item No.:
29
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The interior door bracket was torn loose and the hinges were loose on the Lang ovens.
|
|
Recommendation:
Nonfood preparation equipment must be easily cleanable, in good repair, and corrosion-resistant. It should be constructed in accordance with criteria outlined in the Food Service Equipment Standards of the National Sanitation Foundation.
|
|