Item No.:
14
|
|
Site:
Other-MAIN GALLEY / COFFEE PANTRY
|
|
Violation:
THE REACH-IN REFRIGERATOR HAD AN INTERNAL TEMPERATURE BETWEEN 50-60°F. THERE WERE CONTAINERS OF YOGURT STORED IN THE UNIT WITH AN INTERNAL PRODUCT TEMPERATURE OF 50°F.
|
|
Recommendation:
Since this refrigerator is heavily used during the breakfast service recommend either keeping the potentially hazardous foods on ice or using a different refrigerator.
|
|
|
Item No.:
21
|
|
Site:
Other-PROVISIONS
|
|
Violation:
THE SHELVING UNITS OUTSIDE OF DRY STORES USED TO STORE SPICES HAD SMALL HOLES AND PAINTED STEEL CONSTRUCTION MAKING IT DIFFICULT TO CLEAN.
|
|
Recommendation:
Replace the shelving unit with one that at least has a National Sanitation Foundation (NSF) approval.
|
|
|
Item No.:
14
|
|
Site:
Other-MAIN GALLEY / HOT GALLEY WALK-IN
|
|
Violation:
CONDENSATION FROM THE CONDENSER UNIT WAS DRIPPING ONTO A FOOD TROLLEY LOCATED UNDER THE CONDENSER. THE UNIT WAS DEFROSTING AT THE TIME. ALL OF THE FOOD IN THE TROLLEY WAS PROTECTED BUT THERE WERE OPEN AREAS ON THE TOP OF THE TROLLEY.
|
|
Recommendation:
Recommend either not storing under the condenser or increasing the size of the drip pan to catch all of the condensation.
|
|
|
Item No.:
39
|
|
Site:
Other-GENERAL FOOD SERVICE
|
|
Violation:
THERE WERE SEVERAL AREAS WHERE THE LIGHTING LEVELS WERE BELOW THE REQUIRED 220 LUX (20 FOOD CANDLES). THE AREAS WERE; OVER THE PREP SINK IN THE PASTRY AREA, AND A PROVISIONS FREEZER WERE THE LIGHT LEVEL APPEARED TO BE BELOW THE REQUIRED 110 LUX (10 FOOT CANDLES).
|
|
Recommendation:
Permanently fixed artificial light sources shall be installed to provide, at a distance 30-inches from the deck, at least 20-footcandles of light in utensil and equipment storage areas and at least 10-footcandles of light in walk-in refrigerating units and dry food storage areas.
|
|