Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Wind Spirit Cruise Line: Windstar Cruises Inspection Date: 12/12/1999 Inspection Score: 93
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 29
Site: Other-FOOD SERVICE GENERAL
Violation: THE COUNTER SURROUNDING EQUIPMENT POWER CORDS WAS SOILED WITH DUST IN MANY AREAS.
Recommendation: Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
Item No.: 29
Site: Other-GALLEY - COFFEE PANTRY
Violation: THE COUNTER BENEATH THE CAPPUCCINO MACHINE WAS SOILED WITH DUST.
Recommendation: Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
Item No.: 28
Site: Other-COLD KITCHEN
Violation: THE SLICER WAS HEAVILY SOILED WITH GROSS FOOD DEBRIS AND HAD BEEN LAST USED YESTERDAY.
Recommendation: To prevent cross-contamination, pots, pans, utensils and other food contact surfaces of equipment shall be thoroughly washed, rinsed and sanitized after each use and prior to storage.
Item No.: 21
Site: Other-HOT GALLEY
Violation: THE INTERIOR COMPARTMENT AND GREASE PAN CHUTE FOR THE FLAT TOP GRILL WAS DIFFICULT TO ACCESS AND CLEAN. EXPOSED INSULATION WAS PRESENT IN THE INTERIOR COMPARTMENT.
Recommendation: Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, shall be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and shall be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
Item No.: 7
Site: Other-POT WASH
Violation: THERE WAS A WATER LEAK FROM BENEATH THE THIRD SINK ONTO THE DECK BELOW.
Recommendation: Water supply lines and fixtures must be free from leaks and properly installed. Wastewater from equipment and sinks must be properly drained to prevent pooling or leaking of water on the deck.
Item No.: 11
Site: Other-COLD KITCHEN
Violation: THE AMBIENT AIR TEMPERATURE INSIDE UNDER COUNTER REACH-IN REFRIGERATOR #13 WAS 52 °F. THE UNIT WAS EMPTY AT THE TIME OF THIS INSPECTION BUT WAS NOT POSTED OUT OF ORDER.
Recommendation: Refrigerators used to store potentially hazardous foods must be maintained at 40oF (4.5oC) at all times to assure that potentially hazardous foods stored therein stabilize at or below 45oF (7oC).
Item No.: 38
Site: Other-GALLEY GENERAL
Violation: BROKEN OR CRACKED DECK TILE WERE NOTED IN VARIOUS AREAS THROUGHOUT AND MISSING OR RECESSED TILE GROUTING WAS NOTED.
Recommendation: It is required that decks be maintained so as to be durable and easily cleanable.
Item No.: 11
Site: Other-FOOD SERVICE GENERAL
Violation: SEVERAL UNDERCOUNTER AND UPRIGHT REACH-IN REFRIGERATION UNITS WERE POSTED OUT OF ORDER IN THE GALLEY, MESSES, AND VERANDA.
Recommendation: Ensure that a sufficient number of refrigeration units are in good working order to operate in a sanitary manner and to allow for proper cold temperature control.
Item No.: 29
Site: Other-FOOD SERVICE GENERAL
Violation: THE INTERIOR FRONT COVER OF THE JUICE DISPENSING MACHINES IN THE CREW MESS, JUICE PANTRY, AND ROOM SERVICE PANTRY WERE SOILED WITH JUICE RESIDUE.
Recommendation: Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
Item No.: 39
Site: Other-OFFICERS MESS
Violation: THE ARTIFICIAL LIGHT LEVEL OVER THE COLD TOP WAS BELOW 20 FOOT CANDLES (220 LUX).
Recommendation: It is required that additional lighting be provided to insure at least 20-footcandles of light on all food preparation surfaces.
Item No.: 38
Site: Other-OFFICERS MESS
Violation: THE DECK BENEATH THE FOOD COUNTER WAS DIFFICULT TO CLEAN DUE TO HEAVY PAINT CRACKING, CHIPPING, AND PEELING.
Recommendation: It is required that decks be maintained so as to be durable and easily cleanable.
Item No.: 20
Site: Other-VERANDA COFFEE STATION
Violation: THERE WAS HEAVY CORROSION PRESENT ON THE OVERHEAD INTERIOR PANEL OF THE ICE MAKER AND ON THE SIDE PANELS LEADING INTO THE ICE CHUTE.
Recommendation: Food-contact and ice-contact surfaces must be constructed of materials that are nontoxic, smooth, corrosion-resistant, nonabsorbent, and durable under conditions of normal use.
Item No.: 29
Site: Other-HOT FOOD PREPARATION
Violation: THE INTERIOR CHUTE TO THE FLAT TOP GRILL GREASE PAN WAS SOILED WITH GREASE RESIDUE AND DEBRIS.
Recommendation: Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
Item No.: 7
Site: Other-HOT FOOD PREPARATION
Violation: WATER WAS LEAKING FROM BENEATH THE COLD TOP UNDERCOUNTER REACH-IN REFRIGERATOR #19 AND POOLING ON THE DECK BELOW.
Recommendation: Water supply lines and fixtures must be free from leaks and properly installed. Wastewater from equipment and sinks must be properly drained to prevent pooling or leaking of water on the deck.
Item No.: 38
Site: Other-POOL BAR
Violation: THE BULKHEAD PANEL ADJACENT TO THE SWING ENTRY DOOR WAS BADLY DAMAGED LEAVING A DIFFICULT TO CLEAN GAP.
Recommendation: Decks, bulkheads, and deckheads in food preparation, warewashing, and storage areas, including pantries, shall be designed and constructed for easy cleanability, shall be corrosion-resistant, maintained in good repair, and kept clean.
Item No.: 38
Site: Other-LOUNGE BAR
Violation: THE FRONT BAR DECK WAS COVERED WITH LINOLEUM WHICH WAS PEELING AT DECK PENETRATIONS AND ALONG COUNTER AND BULKHEAD JUNCTURES.
Recommendation: Deck covering must be hard, durable, and nonabsorbent materials which are maintained in good repair.
Item No.: 39
Site: Other-PROVISIONS
Violation: ARTIFICIAL LIGHT LEVELS IN THE FORWARD SECTION OF THE BUTCHERS THAW BOX WERE BELOW 20 FOOT CANDLES (220 LUX).
Recommendation: It is required that additional lighting be provided to insure at least 20-footcandles of light on all food preparation surfaces.
Item No.: 21
Site: Other-PROVISIONS
Violation: BRAIDED NYLON OR CLOTH BUNGEE CORDS WERE USED THROUGHOUT TO RESTRAIN ITEMS ON STORAGE SHELVES.
Recommendation: Replace the cords with easy to clean rubber or plastic cord or bungee.
Item No.: 4
Site: Other-POTABLE WATER SYSTEM
Violation: THE SPRAY RINSE NOZZLE IN THE DISHWASH SINK OF THE VERANDA HUNG BELOW THE SINK FLOOD RIM WITH NO BACKFLOW PREVENTER CONNECTED.
Recommendation: Shorten the spray hose, replace the spring, or install a continuous pressure type backflow preventer on the potable water supply to the sink.
Item No.: 21
Site: Other-FOOD SERVICE GENERAL
Violation: EXCESS LENGTHS OF POWER CORDS CONNECTED TO CASH/CREDIT MACHINES, COFFEE AND HOT WATER DISPENSERS, AND SOME CAPPUCCINO MACHINES WERE DRAPED OR COILED ON COUNTER TOPS IN THE VERANDA COFFEE PANTRY, BEVERAGE COUNTER, WINE STATION, VERANDA AND POOL BARS.
Recommendation: Shorten power cords or hang them so they don't drape counter tops and impede easy cleaning of the space surrounding.
Item No.: 21
Site: Other-GALLEY - COFFEE PANTRY
Violation: THE CAPPUCCINO MACHINE WAS MOUNTED ON ONE INCH LEGS, MAKING CLEANING BENEATH DIFFICULT.
Recommendation: Equipment that is placed on tables or counters, unless portable, shall be sealed to the table or counter or elevated on legs to provide at least a 4-inch clearance between the table or counter and shall be installed to facilitate the cleaning of the equipment and adjacent areas.
Item No.: 20
Site: Other-COLD KITCHEN
Violation: THE SLICER BACKPLATE SEAM WAS FILLED IN WITH SOFT SEALANT.
Recommendation: Replace the soft sealant with a hard, durable material which is approved for food grade applications.
Item No.: 40
Site: Other-HOT GALLEY
Violation: THIS AREA WAS EXTREMELY HOT AND HUMID DUE TO POOR OR MALFUNCTIONING GENERAL VENTILATION.
Recommendation: Ventilation systems shall be adequately designed to remove a large percentage of the hot humid air in food service areas to prevent workers from perspiring profusely and to prevent the accumulation of condensation on deckheads.
Item No.: 29
Site: Other-HOT GALLEY
Violation: THE INTERIOR COMPARTMENTAND GRILL GREASE PAN CHUTE WERE HEAVILY SOILED WITH GREASE. RECOMMEND REPLACEMENT OF THIS UNIT.
Recommendation: Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
Item No.: 28
Site: Other-POT WASH
Violation: SOME OF THE PREVIOUSLY CLEANED PANS WERE FOUND SOILED WITH FOOD RESIDUE ON THE CLEAN STORAGE SHELVES.
Recommendation: To prevent cross-contamination, pots, pans, utensils and other food contact surfaces of equipment shall be thoroughly washed, rinsed and sanitized after each use and prior to storage. Any items which are found to be soiled after being washed, must be returned to the warewashing area for immediate re-washing.
Item No.: 11
Site: Other-GALLEY GENERAL
Violation: THERE WAS NO BLAST CHILLER PROVIDED IN THE GALLEY.
Recommendation: Potentially hazardous food must be refrigerated in a manner that promotes rapid cooling. Such foods prepared in large volumes or quantities can be rapidly cooled utilizing such methods as shallow pans, agitation, quick chilling in freezer units, or ice baths external to the food container. The use of blast freezers are very effective in reducing temperatures quickly.
Item No.: 21
Site: Other-DINING ROOM
Violation: WAITER STATION DOORS HAD PIANO HINGE TYPE FASTENERS WHICH WERE DIFFICULT TO CLEAN. A FEW WERE DAMAGED.
Recommendation: Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, shall be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and shall be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
Item No.: 21
Site: Other-FOOD SERVICE GENERAL
Violation: JUICE DISPENSING MACHINES IN THE CREW MESS, JUICE PANTRY, AND ROOM SERVICE PANTRY WERE DIFFICULT TO CLEAN INSIDE THE FRONT COVER.
Recommendation: Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, shall be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and shall be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
Item No.: 21
Site: Other-FOOD SERVICE GENERAL
Violation: RESIDENTIAL MODEL MICROWAVE OVENS WERE INSTALLED IN BOTH THE OFFICERS MESS AND THE ROOM SERVICE PANTRY.
Recommendation: Replace the residential models with ovens which are constructed according to criteria established by the National Sanitation Foundation (NSF) or equivalent.
Item No.: 39
Site: Other-OFFICERS MESS
Violation: THE ARTIFICIAL LIGHT LEVEL OVER THE DRINK DISPENSERS AND ADJACENT HANDWASH STATION WAS BELOW 20 FOOT CANDLES (220 LUX).
Recommendation: It is required that additional lighting be provided to insure at least 20-footcandles of light on all food preparation surfaces.
Item No.: 21
Site: Other-VERANDA COFFEE STATION
Violation: THE CAPPUCCINO MACHINE WAS MOUNTED ON LEGS ONLY 1.5 INCHES HIGH, MAKING THE COUNTER BELOW DIFFICULT TO ACCESS AND CLEAN.
Recommendation: Equipment that is placed on tables or counters, unless portable, shall be sealed to the table or counter or elevated on legs to provide at least a 4-inch clearance between the table or counter and shall be installed to facilitate the cleaning of the equipment and adjacent areas.
Item No.: 21
Site: Other-HOT FOOD PREPARATION
Violation: THE GRILL GREASE PAN CHUTE TO THE FLAT TOP GRILL WAS DIFFICULT TO CLEAN.
Recommendation: Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, shall be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and shall be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
Item No.: 38
Site: Other-HOT FOOD PREPARATION
Violation: DECORATIVE CERAMIC TILE WAS USED TO COVER THE BULKHEAD BEHIND THE HOT PREPARATION EQUIPMENT IN THIS AREA. DAMAGED AND MISSING TILE WERE NOTED, ESPECIALLY ALONG THE BASEBOARD. THIS AREA SHOULD HAVE STAINLESS STEEL BULKHEADS.
Recommendation: Surfaces subject to routine splashes, spillage, or other soiling during normal use shall have easily cleanable surfaces.
Item No.: 39
Site: Other-POOL BAR
Violation: ARTIFICIAL LIGHT LEVELS OVER THE PREPARATION AND SERVICE COUNTERS COULD NOT BE INCREASED TO 20 FOOT CANDLES (220 LUX) FOR CLEANING PERIODS.
Recommendation: Install additional artificial lighting to be able to raise the level to 20 foot candles (220 lux) during cleaning periods.
Item No.: 21
Site: Other-POOL BAR
Violation: A GAP WAS PRESENT ALONG WHERE THE BULKHEAD JOINS THE GLASS STORAGE COUNTER.
Recommendation: Aisles and working spaces between units of equipment and bulkheads shall be unobstructed and of sufficient width to permit employees to perform their duties readily without contamination of food or food contact surfaces by clothing or personal contact.
Item No.: 20
Site: Other-LOUNGE BAR
Violation: THE BAR PANTRY ICE MACHINE HAD AN OPEN CELL ABSORBENT FOAM GASKET BETWEEN THE UPPER MAKER AND LOWER BIN COMPARTMENTS. SAME PROBLEM EXISTS IN THE ROOM SERVICE PANTRY.
Recommendation: Food-contact and ice-contact surfaces must be constructed of materials that are nontoxic, smooth, corrosion-resistant, nonabsorbent, and durable under conditions of normal use.
Item No.: 14
Site: Other-PROVISIONS
Violation: AN INSECT ELECTROCUTION LAMP WAS MOUNTED OVER A DRY FOOD STORAGE SHELF IN THE PROVISIONS CORRIDOR.
Recommendation: Replace with a glue trap device mounted away from any food storage shelves.
Item No.: 4
Site: Other-POTABLE WATER SYSTEM
Violation: A FLEXIBLE HOSE WAS CONNECTED TO THE POTABLE WATER TAP IN THE GARBAGE ROOM WITH NO BACKFLOW PREVENTER ATTACHED. THIS ITEM WAS CORRECTED DURING THE INSPECTION.
Recommendation: Vacuum breakers and backflow preventers must be properly installed and maintained in good repair at all times to assure reliable operation.