Item No.:
17
|
|
Site:
Other-LIDO GALLEY
|
|
Violation:
FOOD UTENSILS USED IN PREPARATION OF FOOD WERE FOUND STORED IN THE SANITIZE SOLUTION OF THE 3-BUCKET SYSTEM.
|
|
Recommendation:
Between uses during service, food-dispensing utensils shall be stored in the food with the dispensing utensil handle extended out of the food, stored clean and dry or stored in running water.
|
|
|
Item No.:
21
|
|
Site:
Other-PASTRY
|
|
Violation:
THERE WAS AN OPEN SEAM BETWEEN THE OVENS AND THE BULKHEAD.
|
|
Recommendation:
Unless sufficient space is provided for easy cleaning between, behind and above each unit of fixed equipment, the space between it and adjoining equipment and adjacent bulkheads or deckheads shall be not more than 1/32-inch. If exposed to seepage, the equipment shall be sealed to the adjoining equipment or adjacent bulkheads or deckheads.
|
|
|
Item No.:
29
|
|
Site:
Other-PASTRY
|
|
Violation:
THE GAP BETWEEN THE ELECTRICAL CONTROL PANEL BOX AND THE OVEN WAS SOILED WITH DUST.
|
|
Recommendation:
Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
|
|
|
Item No.:
30
|
|
Site:
Other-POT WASH
|
|
Violation:
SOILED EQUIPMENT WAS STORED DIRECTLY ON THE DECK.
|
|
Recommendation:
Sufficient storage space for clean and dirty pots and pans must be provided to avoid contamination of cleaned equipment.
|
|
|
Item No.:
29
|
|
Site:
Other-HOT GALLEY
|
|
Violation:
GREASE HAD SEEPED THROUGH THE PROFILE STRIPS SURROUNDING THE FRYERS AND HAD ACCUMULATED BETWEEN AND UNDERNEATH THE FRYER CABINETS.
|
|
Recommendation:
Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
|
|
|
Item No.:
38
|
|
Site:
Other-PROVISIONS
|
|
Violation:
THE BULKHEAD HAD COLLAPSED IN THIS AREA DUE TO PRODUCTS SHIFTING IN HEAVY SEAS.
|
|
Recommendation:
The bulkheads shall be repaired and reinforced to prevent further collapse problems.
|
|
|
Item No.:
18
|
|
Site:
Other-HOSPITAL
|
|
Violation:
DIARRHEA COUNTS WERE NOT REPORTED TO THE VSP OFFICE PRIOR TO THE SHIP ARRIVING IN LOS ANGELES.
|
|
Recommendation:
Diarrhea logs in the hospital must be accurately maintained, and results must be reported to the Vessel Sanitation Program in accordance with Section III of the "Vessel Sanitation Program Operations Manual", August 1989.
|
|
|
Item No.:
21
|
|
Site:
Other-PASTRY
|
|
Violation:
THERE WAS A NON-EASILY CLEANABLE GAP BETWEEN THE ELECTRICAL CONTROL PANEL BOX AND THE OVEN.
|
|
Recommendation:
Unless sufficient space is provided for easy cleaning between, behind and above each unit of fixed equipment, the space between it and adjoining equipment and adjacent bulkheads or deckheads shall be not more than 1/32-inch. If exposed to seepage, the equipment shall be sealed to the adjoining equipment or adjacent bulkheads or deckheads.
|
|
|
Item No.:
21
|
|
Site:
Other-PASTRY
|
|
Violation:
THE ELECTRICAL CORD TO THE HOT PLATE WAS TOO LONG AND WAS DRAPED ALONG THE COUNTER TOP.
|
|
Recommendation:
The electrical cord shall be shortened.
|
|
|
Item No.:
21
|
|
Site:
Other-HOT GALLEY
|
|
Violation:
THERE WAS A SMALL NON-EASILY CLEANABLE GAP UNDER THE PROFILE STRIPS SURROUNDING THE FRYERS.
|
|
Recommendation:
Unless sufficient space is provided for easy cleaning between, behind and above each unit of fixed equipment, the space between it and adjoining equipment and adjacent bulkheads or deckheads shall be not more than 1/32-inch. If exposed to seepage, the equipment shall be sealed to the adjoining equipment or adjacent bulkheads or deckheads.
|
|
|
Item No.:
38
|
|
Site:
Other-PASTRY
|
|
Violation:
THE EXHAUST HOOD ABOVE THE OVENS RESTRICTED ACCESS FOR CLEANING THE TOPS OF THE OVENS. DUST AND GREASE WAS NOTED ON TOP OF THE OVENS ADJACENT TO THE BULKHEAD.
|
|
Recommendation:
The exhaust hood shall be enlarged to facilitate proper cleaning.
|
|