Cruise Ship: Seven Seas Navigator Cruise Line: Regent Seven Seas Inspection Date: 12/17/1999 Inspection Score: 76
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 1
Site: Other-POTABLE WATER
Violation: Water bunkered from shore was chlorinated to only 1.5 ppm at the time of inspection.
Recommendation: Water samples obtained from the sample cock between the bunkering halogenators and the storage tanks must have a free halogen residual of at least 2.0 ppm.
Item No.: 2
Site: Other-POTABLE WATER
Violation: Free chlorine in the distribution system measured between 10 and 50 ppm.
Recommendation: The potable water distribution system must contain at least 0.2 ppm but must not exceed 5.0 ppm free chlorine or bromine residual. The measurement shall be taken at a distant point in the distribution system.
Item No.: 3
Site: Other-POTABLE WATER
Violation: The chlorine analyzer/recorder indicated 0.85 ppm when the actual level was between 10 and 50 ppm. A review of the chlorine charts indicated less than 0.2 ppm free chlorine for 24 hours 10/29/99. (The following charts indicated extended periods, but less than 24 hours: 10/9/99-8 hr, 10/28/99-13 hr, 10/22/99-12 1/2 hr, 10/23/99-13 hr, 10/24-4 hr, 10/24/99-4 hr, 10/21/99-11 hr, 10/20/99-8 hr, 10/16/99-4 hr, 10/17/99-13 hr).
Recommendation: The analyzer/chart recorder must be properly maintained, operated and calibrated in accordance with the manufacturer's instructions. In the event of unexpected equipment failure, manual methods for halogenation and for determination of halogen residuals may be used temporarily provided that halogen residuals are measured at least once every 8 hours. In such situations, ships must repair the malfunctioning equipment within 10 days. This privilege may be rescinded if abused by ship's staff. A review of records from the ship's automatic chlorine or bromine analyzer must show that the ship has maintained adequate amounts of free halogen residual in the water distribution system since the last inspection of the vessel. The review will be deemed unacceptable if the records show a free halogen residual of less than 0.2 ppm for more than 24 consecutive hours. Charts shall be initialed and dated daily and retained for at least 12-months.
Item No.: 4
Site: Other-POTABLE WATER-BACKFLOW
Violation: There was no backflow protection on the shower in the Hospital.
Recommendation: Provide a backflow preventer on the shower hose.
Item No.: 6
Site: Other-WHIRLPOOL SPAS
Violation: Bromine readings were taken every 4 hours instead of hourly as recommended in the Final Recommendations to Minimize Transmission of Legionnaires' Disease from Whirlpool Spas on Cruise Ships, dated March 25, 1997.
Recommendation:
Item No.: 7
Site: Other-LIDO GALLEY
Violation: There was condensation dripping from pipes above the deckhead and then dripping from around the deckhead hatch onto the deck.
Recommendation: Insulate the pipes and/or otherwise eliminate the dripping of condensation from the deckhead.
Item No.: 14
Site: Other-PROVISIONS
Violation: Bottles of liquor and boxes of liquor were stored on the deck.
Recommendation: Food and beverage products must be stored a minimum of 6 inches above the deck in a manner that protects them from splash and other contamination and that permits easy cleaning of the deck surface below.
Item No.: 14
Site: Other-VEGETABLE FREEZER
Violation: An ice carving was stored with food in the vegetable walk-in freezer.
Recommendation: Non-food items such as ice blocks, flowers, and carvings shall be stored in a designated area separate from food items. Separation may be accomplished by using separate storage racks, physical distance, divider walls or partitions or separate refrigeration units or rooms.
Item No.: 14
Site: Other-LIDO GALLEY
Violation: Press-fitted piping of unknown origin was noted above the deckhead.
Recommendation: Determine what liquid passes through this piping. Drainage lines carrying sewage or other liquid waste shall not pass directly overhead or horizontally through spaces used for the preparation, serving or storage of food or for the washing or storage of utensils.
Item No.: 18
Site: Other-ENTREMETIER
Violation: One employee was observed cutting potatoes with two cuts on his thumb. He was sent to the Hospital where a bandage was applied.
Recommendation: Any person with an open cut, burn or other skin infection shall not handle food or beverages in any food service area. Any person known or suspected to be infected with any communicable disease that can be transmitted via food or beverages must not work in any food service area. This applies to known carriers of communicable diseases as well as to persons with related signs or symptoms, such as boils, sores, infected wounds, diarrhea, jaundice, and abnormal discharge from the nose or mouth.
Item No.: 18
Site: Other-CREW GALLEY-HOT GALLEY
Violation: One employee was observed preparing food with a cut on his hand and a bandage applied to his thumb which he applied himself. He had not visited the Hospital for evaluation or treatment.
Recommendation: Food handlers with cuts or burns shall report to the Hospital for evaluation and treatment. Any person with an open cut, burn or other skin infection shall not handle food or beverages in any food service area. Any person known or suspected to be infected with any communicable disease that can be transmitted via food or beverages must not work in any food service area. This applies to known carriers of communicable diseases as well as to persons with related signs or symptoms, such as boils, sores, infected wounds, diarrhea, jaundice, and abnormal discharge from the nose or mouth.
Item No.: 21
Site: Other-LIDO GALLEY
Violation: Ice bin door gaskets were split at the corners.
Recommendation: Ice bin door gaskets shall be easily cleanable without breaks in the material. The corners shall be closed and sealed and hollow sections shall be sealed.
Item No.: 21
Site: Other-LIDO GALLEY
Violation: There were unplugged, pre-drilled holes in the handwashing sinks and water fountain.
Recommendation: Install plugs in the holes.
Item No.: 26
Site: Other-GALLEY-DISHWASHING/SCULLERY
Violation: The final sanitizing rinse temperature of the conveyor dishwashing machine was 161oF, 150oF and 158oF on consecutive tests. The machine was adjusted and the temperature increased during the inspection.
Recommendation: The final sanitizing rinse on automatic dishwashing machines utilizing hot water for sanitizing shall operate at a minimum of 165oF (74oC) measured at dish level.
Item No.: 30
Site: Other-BARS-GENERAL
Violation: Dishware racks were used as pallets to store beer off of the deck.
Recommendation: Provide appropriate food storage pallets, racks or shelves.
Item No.: 34
Site: Other-CREW BAR
Violation: There were soiled glasses sitting in the handwashing sink.
Recommendation: Handwashing sinks must be accessible to employees at all times.
Item No.: 38
Site: Other-LIDO GALLEY
Violation: There was a large open seam between the buffet and bulkhead.
Recommendation: Surfaces subject to routine splashes, spillage or other soiling during normal use shall have easily cleanable surfaces.
Item No.: 39
Site: Other-CASINO BAR
Violation: Lighting at the coffee preparation counter was less than 20 ft candles.
Recommendation: It is required that additional lighting be provided to insure at least 20 ft candles of light on all food preparation surfaces.
Item No.: 39
Site: Other-STARS BAR
Violation: Lighting over the front bar was less than 20 ft candles.
Recommendation: It is required that additional lighting be provided to insure at least 20 ft candles of light on all food preparation surfaces.
Item No.: 39
Site: Other-VEGETABLE PREPARATION
Violation: Lighting over the vegetable wash sink equipped with a spray hose was less than 20 ft candles.
Recommendation: It is required that additional lighting be provided to insure at least 20 ft candles of light on all food preparation surfaces.