Item No.:
26
|
|
Site:
Other-VERANDA / DISHWASHING AREA
|
|
Violation:
THE IN USE CONVEYOR TYPE DISHWASHING MACHINE HAD A FINAL SANITIZING RINSE TEMPERATURE OF 150oF, MEASURED AT THE DISH SURFACE.
|
|
Recommendation:
Automatic dishwashing machines utilizing hot water for sanitizing shall operate at a minimum of 165oF (74oC) measured at dish level.
|
|
|
Item No.:
19
|
|
Site:
Other-VERANDA
|
|
Violation:
A WAITER WAS OBSERVED DROPPING OFF SOILED DISHES AT THE DISHWASHING AREA THEN RINSING HIS HANDS BRIEFLY IN THE HAND WASHING SINK WITHOUT USING SOAP.
|
|
Recommendation:
All food-handling personnel must wash their hands when reporting to work, after each visit to the toilet, after each break, after handling raw meat, poultry or seafood and after coughing, sneezing, or handling garbage or similar sources of potential contamination of hands. After handling dirty dishes, staffers must wash their hands again before handling clean dishes and utensils.
|
|
|
Item No.:
21
|
|
Site:
Other-VERANDA / HOT KITCHEN
|
|
Violation:
THE SCRAPER USED TO CLEAN THE GRILL WAS DAMAGED AND HAD ROUGH EDGES MAKING IT DIFFICULT TO CLEAN.
|
|
Recommendation:
Nonfood preparation equipment must be easily cleanable, in good repair, and corrosion-resistant.
|
|
|
Item No.:
22
|
|
Site:
Other-VERANDA / DISHWASHING AREA
|
|
Violation:
THE TECHNICAL STAFF CHECKS THE MACHINE ON A DAILY BASIS BUT THERE IS NO ADDITIONAL MONITORING DONE BY THE OPERATORS. THIS MONITORING OF DISHWASHING MACHINE MUST BE A COMBINED TEAM EFFORT TO ENSURE THAT THE CORRECT TEMPERATURES ARE MAINTAINED.
|
|
Recommendation:
|
|
|
Item No.:
19
|
|
Site:
Other-VERANDA
|
|
Violation:
A COOK WAS OBSERVED REMOVING THE LID OF A TRASH CAN TO DUMP COFFEE GROUNDS IN IT. HE WAS WEARING GLOVES AT THE TIME. HE THEN MADE COFFEE WITHOUT CHANGING HIS GLOVES. WHEN DISCUSSING HAND WASHING AND GLOVE USE HE STATED THAT HE HAD WASHED HIS GLOVES BEFORE MAKING THE COFFEE.
|
|
Recommendation:
Employees shall maintain a high degree of personal cleanliness and should conform to good hygienic practices during all working periods in the foodservice area. This includes removing gloves after touching soiled items and washing their hands for at least 20 seconds before putting on clean gloves.
|
|
|
Item No.:
11
|
|
Site:
Other-VERANDA
|
|
Violation:
PLASTIC TRAYS OF YOGURT CONTAINERS WERE STORED ON UNDERCOUNTER REFRIGERATOR SHELVES. THESE TRAYS DID NOT ALLOW PROPER AIR FLOW AND COOLING OF THESE CONTAINERS.
|
|
Recommendation:
Potentially hazardous food must be refrigerated in a manner that promotes rapid cooling.
|
|
|
Item No.:
11
|
|
Site:
Other-MAIN GALLEY / HOT GALLEY
|
|
Violation:
BAIN MARIE PANS OF COOKED CURRIED BEEF WERE STACKED DIRECTLY ON TOP OF EACH OTHER IN HOT HOLDING CABINET INSTEAD OF USING SHELVES TO SEPARATE THEM AND ALLOW GOOD AIR FLOW.
|
|
Recommendation:
Provide shelving in these hot holding cabinets.
|
|
|
Item No.:
12
|
|
Site:
Other-MAIN GALLEY / HOT GALLEY
|
|
Violation:
THE HOT HOLDING CABINETS DID NOT HAVE THERMOMETERS INSTALLED FOR EASY MONITORING OF INTERNAL AMBIENT AIR TEMPERATURES.
|
|
Recommendation:
All hot carts or similar equipment shall have a thermometer to measure the ambient air temperature of the unit.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY / POT WASHING AREA
|
|
Violation:
NUMEROUS PREVIOUSLY CLEAN POTS AND PANS WERE FOUND SOILED WITH FOOD RESIDUE.
|
|
Recommendation:
To prevent cross-contamination, pots, pans, utensils and other food contact surfaces of equipment shall be thoroughly washed, rinsed and sanitized after each use and prior to storage. Any items which are found to be soiled after being washed, must be returned to the warewashing area for immediate re-washing.
|
|
|
Item No.:
26
|
|
Site:
Other-FOOD SERVICE - GENERAL
|
|
Violation:
THE CHLORINE CONCENTRATIONS IN THE POT WASH SANITIZE SINK AND MOST OTHER SANITIZE SINKS AND BUCKETS WERE MEASURED AT 200 PPM OR GREATER.
|
|
Recommendation:
Rinsing, spraying, or swabbing with a chemical sanitizing solution of at least 100 ppm chlorine or 25 ppm iodine must be used on equipment too large to be sanitized by immersion. Such solutions shall not exceed 200 ppm chlorine or 50 ppm iodine.
|
|
|
Item No.:
19
|
|
Site:
Other-CREW DISHWASHING AREA
|
|
Violation:
ONE PERSON WAS ASSIGNED TO WASH DISHES IN THIS AREA. THIS PERSON HANDLED BOTH SOILED AND CLEAN DISHWARE.
|
|
Recommendation:
Provide an additional person to properly handle clean or soiled dishes.
|
|
|
Item No.:
24
|
|
Site:
Other-MAIN GALLEY / COLD PANTRY
|
|
Violation:
CUTTING BOARDS FOUND IN THE SANITIZE SINK WERE SOILED WITH FOOD RESIDUE.
|
|
Recommendation:
Wash and rinse utensils before sanitizing them.
|
|
|
Item No.:
10
|
|
Site:
Other-MAIN GALLEY / COLD PANTRY
|
|
Violation:
TWO PANS OF CURRIED BEEF WERE FOUND IN A REACH-IN REFRIGERATOR WITH INTERNAL PRODUCT TEMPERATURES OF 110oF. THESE ITEMS WERE PREPARED BETWEEN 6-7 AM AND THE TEMPERATURES WERE MEASURED AT 1030 AM.
|
|
Recommendation:
The internal temperature of potentially hazardous foods stored in refrigerators shall be checked and must not exceed 45oF (7oC) after allowing for stabilization at refrigerator temperature. The maximum amount of time that a potentially hazardous food is allowed to be out of temperature (45oF to 140oF or 7oC to 60oC) is 4 hours. This is the total history of the food and includes thawing, preparation time, heating, cooling, and reheating.
|
|
|
Item No.:
11
|
|
Site:
Other-MAIN GALLEY / COLD PANTRY
|
|
Violation:
THE CURRIED BEEF WAS NOT PRE-CHILLED IN THE BLAST CHILLER BECAUSE IT WAS FULL AT THE TIME. ALTERNATIVE METHODS OF RAPID COOLING WERE NOT USED BEFORE PLACING THE BEEF IN THE REACH-IN REFRIGERATOR.
|
|
Recommendation:
Potentially hazardous food must be refrigerated in a manner that promotes rapid cooling. Such foods prepared in large volumes or quantities can be rapidly cooled utilizing such methods as shallow pans, agitation, quick chilling in freezer units, or ice baths external to the food container. The use of blast freezers are very effective in reducing temperatures quickly.
|
|
|
Item No.:
14
|
|
Site:
Other-MAIN GALLEY / PASTRY
|
|
Violation:
TWO BAGS OF RAW SUGAR WERE FOUND STORED DIRECTLY IN CONTACT WITH REFINED SUGAR IN A BULK STORAGE BIN. ALSO THE HANDLE OF THE SUGAR SCOOP WAS IN DIRECT CONTACT WITH THE SUGAR.
|
|
Recommendation:
During transportation and storage, food shall be kept in covered containers or completely wrapped or packaged so as to be protected from contamination.
|
|
|
Item No.:
10
|
|
Site:
Other-CREW MESS
|
|
Violation:
A DEEP BAIN MARIE PAN OF COOKED RICE WAS FOUND ON THE BAIN MARIE WITH AN INTERNAL PRODUCT TEMPERATURE OF 100oF. THE RICE WAS COOKED 3 HOURS EARLIER.
|
|
Recommendation:
Potentially hazardous foods prepared in advance must be promptly stored in refrigerators with air temperatures at or below 40oF (4.5oC), or they must remain heated at or above 140oF (60oC).
|
|
|
Item No.:
11
|
|
Site:
Other-CREW MESS
|
|
Violation:
THE BAIN MARIE WATER TEMPERATURE WHERE THE RICE WAS FOUND HAD A TEMPERATURE OF 144oF AND WAS NOT IN DIRECT CONTACT WITH THE CONTAINER OF RICE.
|
|
Recommendation:
Sufficient baine-maries and other heat retention equipment for storing and transporting potentially hazardous food must be provided and maintained to assure that all foods are held at or above 140oF (60oC). This equipment shall not be used to heat food.
|
|
|
Item No.:
34
|
|
Site:
Other-CREW TOILET
|
|
Violation:
THE CREW TOILET CLOSEST TO THE CREW MESS DID NOT HAVE HAND SOAP OR PAPER TOWELS AVAILABLE. THIS TOILET IS POTENTIALLY USED BY THE FOOD SERVICE WORKERS AND MUST BE PROPERLY SUPPLIED.
|
|
Recommendation:
Provide soap and single use paper towels to allow proper hand washing.
|
|
|
Item No.:
14
|
|
Site:
Other-PROVISIONS
|
|
Violation:
NUMEROUS SEVERELY DENTED CANS WERE FOUND IN THE DRY STORES.
|
|
Recommendation:
Discard cans if they are severely dented on any of the sealing surfaces such as tops and bottoms.
|
|