Cruise Ship: Wind Spirit Cruise Line: Windstar Cruises Inspection Date: 04/02/2000 Inspection Score: 84
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 3
Site: Other-POTABLE WATER SYSTEM
Violation: TEST KIT PROVIDED TO CALIBRATE THE CHLORINE ANALAYZER-CHART RECORDER DOES NOT HAVE THE PRECISION OF 0.2 mg/L (PPM) TO PROPERLY PERFORM THIS PROCEDURE. ABOVE 1.0 mg/L (PPM) VESSEL'S KIT WAS GRADUATED IN 0.5 mg/L (PPM) INCREMENTS.
Recommendation: The analyzer and chart recorder must be properly maintained, operated and calibrated in accordance with the manufacturer's instructions.
Item No.: 4
Site: Other-GENERAL FOOD SERVICE
Violation: PLASTIC HOSES HAD BEEN CLAMPED ON BACKFLOW PREVENTERS IN A POSITION WHEREBY THE END OF THE HOSE COVERED THE AIR RELIEF HOLES MAKING THE VALVE INEFFECTIVE IN AT LEAST FOUR INSTANCES.
Recommendation: Vacuum breakers and backflow preventers must be properly installed and maintained in good repair at all times to assure reliable operation.
Item No.: 10
Site: Other-HOT GALLEY
Violation: A PAN OF SHRIMP WAS FOUND IN THE HOT GALLEY IN A REACH-IN COOLER (UNIT #5) WITH A PRODUCT TEMPERATURE OF 50°F. SHRIMP WAS DISCARDED.
Recommendation: Potentially hazardous food requiring refrigeration shall be stored at or below 45°F.
Item No.: 10
Site: Other-COLD GALLEY
Violation: A PLATE OF HAM WAS FOUND IN REACH-IN COOLER (UNIT #15) AT 50°F. THE HAM WAS DISCARDED.
Recommendation: Potentially hazardous food requiring refrigeration shall be stored at or below 45°F.
Item No.: 10
Site: Other-CREW MESS
Violation: MILK IN REACH-IN COOLER WAS FOUND AT 51°F.
Recommendation: Refrigerators used to store potentially hazardous foods must be maintained at 40°F (4.5°C) at all times to assure that potentially hazardous foods stored therein stabilize at or below 45°F (7°C). When refrigeration problems are noted, potentially hazardous foods should be checked to assure they are still below 45°F and then moved to properly operating units. If higher temperatures are noted, the affected product should be discarded. The malfunctioning unit should be placed Out of Order until proper temperature maintenance is assured.
Item No.: 11
Site: Other-COLD GALLEY
Violation: REACH-IN COOLER (UNIT #15) AMBIENT TEMPERATURE WAS RECORDED AT 55°F.
Recommendation: Refrigerators used to store potentially hazardous foods must be maintained at 40°F (4.5°C) at all times to assure that potentially hazardous foods stored therein stabilize at or below 45°F (7°C). When refrigeration problems are noted, potentially hazardous foods should be checked to assure they are still below 45°F and then moved to properly operating units. If higher temperatures are noted, the affected product should be discarded. The malfunctioning unit should be placed Out of Order until proper temperature maintenance is assured.
Item No.: 11
Site: Other-HOT GALLEY
Violation: COOLER TEMPERATURE (UNIT #5) WAS NOTED ON AMBIENT THERMOMETER AT 55°F. FOUND OTHER PRODUCTS STORED IN UNIT OVERNIGHT AT 49°-51°F. DURING CLOSING CONFERENCE, STAFF STATED CENTRAL REFRIGERATION SYSTEM HAD BEEN UNDER REPAIR THE NIGHT BEFORE ACCOUNTING FOR THIS UNIT'S PROBLEMS AND OTHER HIGH TEMPERATURES NOTED IN OTHER UNITS DURING INSPECTION. A REVIEW OF THE LOGS INDICATED HIGH TEMPERATURES WERE NOTED IN VARIOUS UNITS BY CREW OVER THE PAST SEVERAL MONTHS.
Recommendation: Refrigerators used to store potentially hazardous foods must be maintained at 40°F (4.5°C) at all times to assure that potentially hazardous foods stored therein stabilize at or below 45°F (7°C). When refrigeration problems are noted, potentially hazardous foods should be checked to assure they are still below 45°F and then moved to properly operating units. If higher temperatures are noted, the affected product should be discarded. The malfunctioning unit should be placed Out of Order until proper temperature maintenance is assured. When high temperatures are noted in routine monitoring, it is helpful to track these problems and their resolution in the temperature logs or by other recordkeeping systems.
Item No.: 14
Site: Other-PROVISIONS - COLD STORES
Violation: A PAN OF COOKED SAUSAGE WAS FOUND IN A WALK-IN COOLER WITH A TORN ALUMINUM FOIL COVER. RAW MEAT WAS DEFROSTING IN THIS COOLER CREATING A POTENTIAL CROSS CONTAMINATION PROBLEM. SAUSAGE WAS STORED ON TOP SHELF.
Recommendation: During storage, food shall be kept in covered containers or completely wrapped or packaged so as to be protected from contamination.
Item No.: 18
Site: Other-MEDICAL
Violation: REQUIRED DIARRHEA LOG FOR CRUISES 516, 517 AND 516 (03/05/2000 - 03/19/2000) WITH PASSENGERS / CREW ABOARD 115/89, 128/90 AND 139/92 RESPECTIVELY, WAS NOT MAINTAINED.
Recommendation: Diarrhea logs in the hospital must be accurately maintained, and results must be reported to the Vessel Sanitation Program in accordance with Section III of the "Vessel Sanitation Program Operations Manual", August 1989. With rotating medical staff used on the Wind Spirit, briefing on log maintenance and reporting should be included in orientation and verified by ship personnel.
Item No.: 20
Site: Other-COLD GALLEY
Violation: A SEAM WAS FOUND BETWEEN HARD SEALANT AND BACK PLATE OF SLICER CREATING A DIFFICULT TO CLEAN AREA.
Recommendation: Food preparation equipment must be easily cleanable and in good repair.
Item No.: 20
Site: Other-HOT GALLEY
Violation: BRAISING SKILLET HAD A DEEP CRACK IN INTERIOR AT OUTLET.
Recommendation: Food-contact surfaces must be easily cleanable and free of difficult-to-clean crevices.
Item No.: 20
Site: Other-COLD GALLEY
Violation: RUST WAS NOTED IN THE ICE MAKER UNIT MAKING IT DIFFICULT TO CLEAN.
Recommendation: Ice-contact surfaces must be constructed of materials that are smooth and corrosion-resistant.
Item No.: 21
Site: Other-HOT GALLEY
Violation: GRILL GREASE PAN TRAY ENCLOSURE HAD EXPOSED INSULATION MATERIAL THAT WAS DIFFICULT TO CLEAN.
Recommendation: THE APPROVED METHOD FOR DISINFECTING SHIPBOARD POTABLE WATER IS CONTINUOUS HALOGENATION WITH AN AUTOMATIC HYPOCHLORINATOR OR BROMINATOR THAT INJECTS AN AMOUNT PROPORTIONAL TO THE WATER FLOW. THIS IS ACCOMPLISHED BY MEANS OF A WATER FLOW METER OR A FREE HALOGEN ANALYZER WIRED IN WITH THE PUMP TO CONTROL THE AMOUNT OF CHLORINE OR BROMINE INJECTED. THE HALOGENTION SYSTEM MUST BE LOCATED ON THE DISTRIBUTION LINE BEFORE THE SERVICE LINES.
Item No.: 21
Site: Other-GENERAL FOOD SERVICE
Violation: CAPPUCCINO MACHIES WERE MOUNTED ON SHORT LEGS MAKING CLEANING DIFFICULT. NEW LEGS WERE ON BOARD BUT HAVE NOT BEEN INSTALLED, YET. SOIL WAS NOTED ON COUNTER UNDER THE MACHINE IN THE COLD GALLEY.
Recommendation: Equipment that is placed on tables or counters, unless portable, shall be sealed to the table or counter or elevated on legs to provide at least a 4-inch clearance between the table or counter and shall be installed to facilitate the cleaning of the equipment and adjacent areas.
Item No.: 21
Site: Other-GENERAL FOOD SERVICE
Violation: DIFFICULT TO CLEAN JUICE DISPENSING MACHINES NOTED IN ITEM 19 AS SOILED WERE INSTALLED IN THE CREW MESS, VERANDA AND DECK PANTRY.
Recommendation: Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, shall be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and shall be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
Item No.: 22
Site: Other-VERANDA
Violation: FINAL RINSE PRESSURE ON DISHWASHING MACHINE WAS NOT ADEQUATE TO COMPLETELY REMOVE DETERGENT.
Recommendation: Dishwashing machines shall be maintained in good repair. Machines shall be operated in accordance with manufacturers' instructions.
Item No.: 22
Site: Other-DISHWASHING
Violation: CONVEYOR DISHWASHING MACHINE HAD TWO SPRAY NOZZLES ON LOWER FINAL RINSE MANIFOLD CLOGGED.
Recommendation: Dishwashing machines shall be maintained in good repair. Machines shall be operated in accordance with manufacturers' instructions, and utensils and equipment placed in the machine shall be exposed to all dishwashing cycles.
Item No.: 28
Site: Other-DISHWASHING
Violation: SOIL WAS NOTED ON SERVING PLATTER AND BOWLS FOUND IN THE CLEAN UTENSIL STORAGE AREAS.
Recommendation: Utensils shall be thoroughly washed, rinsed and sanitized after each use and prior to storage. Any items which are found to be soiled after being washed, must be returned to the warewashing area for immediate re-washing.
Item No.: 28
Site: Other-POT WASH
Violation: SOIL WAS FOUND ON UTENSILS IN THE CLEAN STORAGE AREA.
Recommendation: Pots, pans, utensils and other food contact surfaces of equipment shall be thoroughly washed, rinsed and sanitized after each use and prior to storage. Any items which are found to be soiled after being washed, must be returned to the warewashing area for immediate re-washing.
Item No.: 28
Site: Other-HOT GALLEY
Violation: CRACK IN BRAISING SKILLET INTERIOR WAS FILLED WITH OLD FOOD DEBRIS.
Recommendation: BYPASS LOOPS ARE NOT ALLOWED UNLESS A HALOGENATED IS ALSO ON THE LOOP.
Item No.: 28
Site: Other-HOT GALLEY
Violation: FRYER HEATING ELEMENTS WERE HEAVILY ENCRUSTED WITH OLD GREASE RESIDUE.
Recommendation:
Item No.: 28
Site: Other-VERANDA
Violation: GREASE WAS ENCRUSTED ON FRYER HEATING ELEMENTS.
Recommendation: The food contact surfaces of grills, griddles and similar cooking devices shall be cleaned at least once per day.
Item No.: 29
Site: Other-BAKERY
Violation: OLD FOOD SOIL WAS NOTED ON SIDES AND SEAMS OF OVEN.
Recommendation: THE FREE HALOGEN RESIDUAL MEASURED BY THE ANALYZER MUST COMPARE WITHIN 0.2 PPM OF THE ACTUAL HALOGEN LEVEL. THE ANALYZER AND CHART RECORDER MUST BE PROPERLY MAINTAINED, OPERATED, AND CALIBRATED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. A REVIEW OF RECORDS FROM THE SHIP'S AUTOMATIC CHLORINE OR BROMINE ANALYZER MUST SHOW THAT THE SHIP HAS MAINTAINED ADEQUATE AMOUNTS OF FREE HALOGEN RESIDUAL IN THE WATER DISTRIBUTION SYSTEM SINCE THE LAST INSPECTION OF THE VESSEL. CHARTS SHALL BE INITIALED AND DATED DAILY AND RETAINED FOR AT LEAST 12 MONTHS.
Item No.: 29
Site: Other-OFFICERS MESS
Violation: SOIL WAS FOUND AROUND THE SNEEZE GUARD SUPPORT STAND ON THE COLD BUFFET.
Recommendation: Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
Item No.: 29
Site: Other-CREW MESS
Violation: HEAVY SOIL WAS NOTED INSIDE THE FRONT COVER OF THE JUICE DISPENSING MACHINE.
Recommendation: Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
Item No.: 29
Site: Other-VERANDA
Violation: OLD GREASE WAS NOTED INSIDE FRYER CABINET.
Recommendation: Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
Item No.: 38
Site: Other-BAKERY
Violation: DECKS WERE SOILED BEHIND PREP TABLE AND UNDERNEATH HANDWASH SINK.
Recommendation: Decks in food preparation areas shall be kept clean.
Item No.: 38
Site: Other-LOUNGE BAR
Violation: VINYL FLOORING MATERIAL IN BAR COUNTER AREA HAD SEAMS AT PIPE PENETRATIONS AND AT BULKHEAD JUNCTURES THAT WERE OPEN AND DIFFICULT TO CLEAN.
Recommendation: It is required that decks be maintained so as to be durable and easily cleanable.
Item No.: 38
Site: Other-PROVISIONS - COLD STORES
Violation: FOAM INSULATION MATERIAL ON CONDENSATION DRAIN LINE WAS DIFFICULT TO CLEAN. SOIL WAS NOTED ON THESE LINES AND IN SEAM WHERE THEY ARE ATTACHED TO THE BULKHEAD. DUCK TAPE WAS ALSO NOTED ON SEVERAL OF THESE LINES TO ATTACH THE LINES TO THE EVAPORATOR PANS.
Recommendation: Exposed utility service lines and pipes shall be installed in a way that does not obstruct or prevent cleaning of decks or bulkheads. Surfaces subject to routine splashes, spillage, or other soiling during normal use shall have easily cleanable surfaces. Attached equipment shall be kept clean.
Item No.: 38
Site: Other-PROVISIONS - COLD STORES
Violation: A LEAK WAS NOTED FROM THE DECKHEAD IN THE GENERAL FROZEN STORES WALK-IN. ICE WAS MOUNDED UP ON THE DECK SEVERAL INCHES DEEP UNDER THE LEAK. SOME ICE HAD ALSO FORMED ON A CARTON OF FOOD FROM THIS LEAK.
Recommendation: Deckheads in food storage areas shall be maintained in good repair. The source of the leak should be traced and eliminated.
Item No.: 38
Site: Other-GENERAL FOOD SERVICE
Violation: DECKS IN GALLEY AREAS AND PROVISIONS HAD DIFFICULT TO CLEAN FEATURES SUCH AS ROUGH TEXTURE CONCRETE, MISSING OR CRACKED DECK TILES AND RECESSED GROUT.
Recommendation: Decks shall be designed and constructed to facilitate being easily cleaned.
Item No.: 39
Site: Other-GENERAL FOOD SERVICE
Violation: LIGHTING IN SEVERAL GALLEY AREAS INCLUDING BAKERY AND SERVING AREAS SUCH AS THE OFFICER'S MESS, AND IN PROVISION COOLERS WAS LESS THAN 20 FT CANDLES (220 LUX) AND 10 FT CANDLES (110 LUX) RESPECTIVELY. A THOROUGH LIGHT INTENSITY SURVEY IS RECOMMENDED.
Recommendation: