Item No.:
26
|
|
Site:
Other-GALLEY
|
|
Violation:
SOFT SEALANT WAS USED ON THE BACKPLATE OF THE SLICER.
|
|
Recommendation:
A hard durable sealant shall be used.
|
|
|
Item No.:
21
|
|
Site:
Other-GALLEY
|
|
Violation:
THE INTERIOR SPACE OF THE FRYER WAS NOT EASILY CLEANABLE.
|
|
Recommendation:
Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material. Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Other-GALLEY
|
|
Violation:
THE INTERIOR OF THE FRYER WAS SOILED WITH GREASE RESIDUE.
|
|
Recommendation:
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Other-LOUNGE BAR PANTRY
|
|
Violation:
A BLACK ABSORBENT GASKET WAS USED IN THE ICE BIN.
|
|
Recommendation:
Nonfood-contact equipment shall be maintained in good repair and proper adjustment including:
(2) Equipment components such as doors, seals, hinges, fasteners, and kick plates shall be kept intact, tight, and adjusted in accordance with manufacturer's specifications.
|
|
|
Item No.:
33
|
|
Site:
Other-LOUNGE BAR
|
|
Violation:
THE DECK WAS NOT COVED AT THE DECK/BULKHEAD JUNCTURE.
|
|
Recommendation:
Bulkhead and deck junctures shall be coved.
|
|
|
Item No.:
10
|
|
Site:
Other-POOL & JACUZZI
|
|
Violation:
ANTI-VORTEX DRAIN COVERS WERE NOT PROVIDED.
|
|
Recommendation:
Anti-vortex drain covers shall be provided on swimming pools and whirlpool spas.
|
|
|
Item No.:
10
|
|
Site:
Other-POOL & JACUZZI
|
|
Violation:
PROVIDE AN APPROVED FLOTATION DEVICE & SHEPHERDS HOOK AT THE POOL.
|
|
Recommendation:
|
|
|
Item No.:
10
|
|
Site:
Other-POOL & JACUZZI
|
|
Violation:
ENSURE THAT ALL NEW REGULATIONS FROM THE VSP OPERATIONS MANUAL 2000 ARE IMPLEMENTED.
|
|
Recommendation:
|
|
|
Item No.:
06
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
RANDOM TEST FOR E-COLI WERE NOT CONDUCTED.
|
|
Recommendation:
A minimum of four potable water samples per month shall be collected and analyzed for the presence of Escherichia coli. Samples shall be collected randomly from locations forward, aft, upper, and lower decks of the vessel.
|
|
|
Item No.:
06
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
MICRO TEST REPORTS FOR WATER BUNKERED FROM SHORE WERE NOT PROVIDED.
|
|
Recommendation:
Where available, the vessel shall have a copy of the most recent microbiologic report from each port before bunkering potable water to verify that the water meets potable standards. These records shall be maintained on the vessel for 12 months and shall be available to the VSP for review during inspections.
|
|