Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seven Seas Navigator Cruise Line: Regent Seven Seas Inspection Date: 03/29/2001 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE CHARTS RANGE WAS 0-50 PPM.
Recommendation: 5.5.2.1.1 Halogen analyzer-chart recorder charts shall have a range of 0.0 to 5.0 mg/L (ppm) and have a recording period of 24 hours.
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE BACTERIOLOGICAL TEST KITS WERE NOT OF AN APPROVED TYPE.
Recommendation: 5.6.1.1.2 Samples shall be analyzed utilizing a method accepted in Standard Methods for the Examination of Water and Wastewater.
Item No.: 41
Site: Other-VENTILATION
Violation: THE CLEANING SCHEDULE FOR THE AIR HANDLING UNITS DID NOT INCLUDE THE CONDENSATE COLLECTION SYSTEM.
Recommendation: 9.2.1.2.3 Vessels shall have a plan to inspect and maintain heating, ventilation, and air conditioning systems in accordance with manufactures recommendations and industry standards.
Item No.: 40
Site: Other-INTEGRATED PEST MANAGEMENT
Violation: TRAINING WAS NOT DOCUMENTED IN THE IPM PLAN.
Recommendation: 8.1.2.1.3 The training of the pest-control personnel shall be documented in the Integrated Pest Management Plan.
Item No.: 10
Site: Other-SPAS
Violation: THE PRECAUTIONS AND RISKS SIGN DID NOT CAUTION IMMUNOCOMPROMISED INDIVIDUALS.
Recommendation: 6.4.1.1.3 A sign shall be installed near the whirlpool spas that lists standard safety precautions and risks, warning against use by particularly susceptible people, such as those who are immunocompromised.
Item No.: 08
Site: Other-LIDO POT WASH
Violation: THE POTABLE WATER LINES TO THE SPRAYHOSE AND PULPER WERE NOT FITTED WITH BACKFLOW PREVENTION DEVICES.
Recommendation: 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 27
Site: Other-POOL GRILL
Violation: THE CLEAN STORAGE RACKS WERE SOILED.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 22
Site: Other-POOL GRILL
Violation: THE WARE WASHING UNITS WERE NOT PROVIDED WITH DATA PLATES.
Recommendation: 7.5.2.2.3 A warewashing machine shall be provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: 22
Site: Other-MAIN DISHWASHING
Violation: THE MAIN DISHWASHER DID NOT HAVE A DATA PLATE.
Recommendation: 7.5.2.2.3 A warewashing machine shall be provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: 24
Site: Other-MAIN & CREW POTWASH
Violation: NONE OF THE POTWASH STAFF NEW THE NEW HALOGEN SANITIZING TIME REQUIREMENTS.
Recommendation: 7.5.6.2.2 A chemical sanitizer shall be used in accordance with the EPA-approved manufacturer's label use instructions at a minimum temperature of 24°C (75°F) with an exposure time of 7 seconds for a chlorine solution and 30 seconds for other chemical sanitizers.
Item No.: 16
Site: Other-PROVISIONS
Violation: A LARGE WHEEL OF CHEESE THAT HAD BEEN SLICED WAS NOT DATED.
Recommendation: 7.3.5.3.2 Refrigerated, ready-to-eat, potentially hazardous food: (2) A container of refrigerated, ready-to-eat potentially hazardous food prepared and packaged by a food processing plant shall be clearly marked, at the time the original container is opened, to indicate the date by which the food shall be consumed which is, including the day the original container is opened, 7 calendar days or fewer after the original container is opened.
Item No.: 10
Site: Other-SPAS
Violation: VERIFY THAT THE DRAIN COVERS ARE ANTI-VORTEX.
Recommendation: 6.4.1.2.2 Anti-vortex drain covers shall be provided on swimming pools and whirlpool spas.
Item No.: 16
Site: Other-LIDO BUFFET
Violation: COLD CUTS WERE TESTED AT 47°F.
Recommendation: 7.3.5.3.1.1 Potentially hazardous food shall be maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above,; or (2) At 5°C (41°F) or less.
Item No.: 26
Site: Other-LIDO DINING ROOM
Violation: SOME CLEAN BREAD BASKETS WERE SOILED WITH BREAD CRUMBS.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 27
Site: Other-POOL GRILL
Violation: SOME MOLD WAS NOTED IN THE TECHNICAL SPACE UNDERNEATH THE SINK.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 08
Site: Other-POOL GRILL
Violation: BACKFLOW PREVENTION DEVICES WERE NOT PROVIDED ON THE WARE WASHING UNITS.
Recommendation: 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 22
Site: Other-MAIN DISHWASHING
Violation: THE MAIN DISHWASHER TEMPERATURE GAUGES WERE OUT 30 TO 60° OUT OF CALIBRATION.
Recommendation: 7.5.2.1.1 Water temperature measuring devices: (1) That are scaled in Celsius or dually scaled in Celsius and Fahrenheit shall be designed to be accurate to ±1.5°C in the intended range of use. (2) That are scaled only in Fahrenheit shall designed to be accurate to ±3°F in the intended range of use.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program