Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Club Med 2 Cruise Line: Club Med Marine Inspection Date: 04/11/2001 Inspection Score: 94
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 31
Site: Other-BARS
Violation: CLEANING LOCKER IN SHOW LOUNGE PANTRY WAS ABOVE A COUNTER WHERE CLEANED UTENSILS WERE STORED. CHEMICALS WERE STORED IN THIS LOCKER CREATING A POTENTIAL CONTAMINATION PROBLEM.
Recommendation: 7.6.2.1.2 Poisonous or toxic materials used in food area cleaning and maintenance shall be stored so they cannot contaminate food, equipment, utensils, linens, and single-service and single-use articles by separating the poisonous or toxic materials by storing in a cleaning materials locker.
Item No.: 33
Site: Other-GRAND BLEU
Violation: BREAKFAST STORAGE PANTRY BEHIND HOT SERVICE LINE HAD CRACKED DECK TILES MAKING THIS AREA DIFFICULT TO CLEAN.
Recommendation: 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
Item No.: 27
Site: Other-GRAND BLEU
Violation: HOT GRILL LINE COUNTER WAS HEAVILY SOILED WITH OLD GREASE RESIDUE BELOW GRILL.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Other-PROVISIONS
Violation: THERE WERE SEVERAL LOOSE PROFILES AND OPEN SEAMS IN THE PROVISION ROOMS.
Recommendation: 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
Item No.: 26
Site: Other-PROVISIONS
Violation: A PREVIOUSLY CLEANED PLASTIC BIN USED TO TRANSPORT VEGETABLES WAS FOUND SOILED IN THE VEGETABLE PREP ROOM.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 30
Site: Other-PROVISIONS
Violation: THE HANDWASHING FACILITIES IN THE TOILET ROOM AND GARBAGE ROOM DID NOT HAVE SOAP AND PAPER TOWELS.
Recommendation: 7.7.1.3.2 Handwashing facilities shall be kept clean and in good repair.
Item No.: 30
Site: Other-PROVISIONS
Violation: THE HANDWASH SINK IN THE GARBAGE ROOM WAS SOILED AND NOT SEALED TO THE BULKHEAD.
Recommendation: 7.7.1.3.2 Handwashing facilities shall be kept clean and in good repair.
Item No.: 38
Site: Other-PROVISIONS
Violation: THE MOP STORED IN THE GARBAGE ROOM WAS STORED IN A BUCKET OF SOILED WATER.
Recommendation: 7.7.7.1.4 After use, mops shall be placed in a position that allows them to air-dry without soiling walls, equipment, or supplies.
Item No.: 32
Site: Other-PROVISIONS
Violation: THE GARBAGE ROOM WAS NOT WELL MAINTAINED AND CLEAN.
Recommendation: 7.7.2.2.4 The garbage and refuse storage room shall be maintained in good repair and kept clean.
Item No.: 08
Site: Other-MAIN GALLEY
Violation: A BACKFLOW PREVENTION DEVICE WAS FOUND LEAKING IN THE BAKERY.
Recommendation: 5.7.2.2.1 Backflow prevention devices should be periodically inspected and any failed units shall be replaced.
Item No.: 28
Site: Other-MAIN GALLEY
Violation: THERE WAS EXCESSIVE USE OF WATER FOR CLEANING IN THE GALLEY FOR DECKS, AND FOOD CONTACT SURFACES.
Recommendation: 7.5.7.3.1 Cleaned equipment and utensils, laundered linens, and single-service and single-use articles shall be stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 22
Site: Other-MAIN GALLEY
Violation: SPONGES WERE BEING USED IN THE SANITIZING BUCKET OF THE THREE BUCKET CLEANING SYSTEM. [NEW VSP OPERATIONS MANUAL 2000 GUIDELINE]
Recommendation: 7.5.5.5.2 Sponges may not be used in contact with cleaned and sanitized or in-use food-contact surfaces.
Item No.: 33
Site: Other-DINING ROOM
Violation: THE CLEAN STATION ON THE STARBOARD SIDE HAD A GAP WHERE IT WAS ATTACHED TO THE BULKHEAD.
Recommendation: 7.7.4.1.8 Surfaces subject to routine splashes, spillage or other soiling during normal use shall have easily cleanable features.
Item No.: 16
Site: Other-DINING ROOM
Violation: THE VESSEL DID NOT HAVE A CONSUMER ADVISORY IN PLACE. [NEW VSP OPERATIONS MANUAL 2000 GUIDELINE]
Recommendation: 7.3.6.1.1 If an animal food such as beef, eggs, fish, lamb, milk, pork, poultry, or shellfish that is raw, undercooked, or not otherwise processed to eliminate pathogens is offered in a ready-to-eat form or as a raw ingredient in another ready-to-eat food, the passengers shall be informed by vessel newsletter articles, brochures, embarkation television broadcasts, menu advisories, placards, or other written means of the significantly increased risk to certain especially vulnerable consumers eating such foods in raw or undercooked form.
Item No.: 02
Site: Other-MEDICAL
Violation: THE VESSEL DID NOT IMPLEMENT THE FOLLOWING ITEMS USE OF THE GASTROINTESTINAL LOG, 72 HOUR FOOD HISTORY FOR PASSENGERS OR CREW HAVING A GI ILLNESS, AND LOG OF ANTIDIARRHEAL MEDICATION SOLD OR DISPENSED. [NEW VSP OPERATIONS MANUAL 2000 GUIDELINE]
Recommendation: 4.1.2.1.1 A standardized gastrointestinal illness surveillance log for each cruise shall be maintained daily by the master of the vessel, the medical staff, or other designated staff. 4.1.2.1.2 The gastrointestinal illness surveillance log shall list the name of the vessel, the cruise dates and the cruise number. 4.1.2.1.3 The log shall list: (1) All reportable cases of gastrointestinal illness; (2) All passengers and crew members who are dispensed antidiarrheal medication from the master of the vessel, the medical staff, or other designated staff. 4.1.2.1.4 The gastrointestinal illness surveillance log entry for each passenger or crew member shall contain the following information: (1) The first date of clinic visit or report to staff of illness; (2) The person's name, age and gender; (3) A designation as passenger or crew member; (4) Crew member position or job on the vessel, if applicable; (5) Cabin number; (6) Meal seating information; (7) Date and time of illness onset; (8) Illness symptoms, including the presence of the following selected signs and symptoms: numbers of episodes each of diarrhea and vomiting per day, bloody stools, fever, recorded temperature; (9) Notation on whether or not a stool specimen was requested and received; (10) Use of antidiarrheal medication; and (11) The presence of underlying medical conditions which may affect interpretation of acute gastrointestinal illness for example diabetic diarrhea, inflammatory bowel disease, gastrectomy or others. 4.1.2.1.5 A separate inventory of the daily total, by quantity and type, of antidiarrheal medications sold or dispensed to the passengers or crew members in all areas of the vessel shall be maintained alongside the gastrointestinal illness surveillance log. 4.1.2.2.1 Questionnaires detailing activities and meal locations for the 72 hours before illness onset shall be distributed to all passengers and crew members who are gastrointestinal illness cases. The self-administered questionnaires shall contain all of the data elements that appear in the questionnaire found in Annex 13.2. The completed questionnaires shall be maintained alongside the gastrointestinal illness surveillance log. 4.1.2.3.1 The medical log, gastrointestinal illness log, the daily inventory of antidiarrheal medication sales, and the 72 hour self-administered questionnaires shall be maintained on the vessel for 12 months. 4.1.2.3.1 The gastrointestinal illness surveillance log, the daily inventory of antidiarrheal medication sales, and the 72 hour self-administered questionnaires shall be available for review by the VSP during inspections and outbreak investigations. These materials shall be transmitted by facsimile to the VSP for review in outbreak investigations, as requested.
Item No.: 40
Site: Other-PEST MANAGEMENT
Violation: THE VESSEL SHOULD ENSURE THAT ALL ELEMENTS OF THE INTEGRATED PEST MANAGEMENT PLAN ARE IMPLEMENTED AS OUTLINED IN CHAPTER 8 OF THE VSP OPERATIONS MANUAL. [NEW VSP OPERATIONS MANUAL 2000 GUIDELINE]
Recommendation: 8.1.1.1.1 Each vessel shall develop an Integrated Pest Management Plan to address effective monitoring and control strategies for pests aboard the vessel.
Item No.: 06
Site: Other-POTABLE WATER
Violation: HALOGEN ANALYZER-CHART RECORDER CHART WAS NOT GRADUATED FROM 0.0 - 5.0 MG/L (PPM)/L (PPM). RANGE OF RECORDING WAS MAXIMUM OF 2.0 MG/L (PPM)/L (PPM) AND ON MORE THAN 10 OCCASIONS IN LAST TWO MONTHS, RECORDED LEVELS EXCEEDED CHART MAXIMUM. [NEW VSP OPERATIONS MANUAL 2000 GUIDELINE]
Recommendation: 5.5.2.1.1 Halogen analyzer-chart recorder charts shall have a range of 0.0 to 5.0 mg/L (ppm) and have a recording period of 24 hours.
Item No.: 06
Site: Other-POTABLE WATER
Violation: A BACKUP HALOGENATION PUMP WITH AUTOMATIC SWITCHOVER IN THE EVENT OF A PRIMARY PUMP FAILURE WAS NOT INSTALLED.
Recommendation: 5.4.1.2.3 At least one backup halogen pump shall be available with automatic switchover to maintain the free residual halogen in the event that the primary pump fails. [ NOTE: Previously cited and points will be deducted if not installed by next inspection.]
Item No.: 08
Site: Other-POTABLE WATER
Violation: ENSURE NEW MANUAL PROVISIONS FOR POTABLE WATER SYSTEM ARE IMPLEMENTED INCLUDING: BUNKERING MICROBIOLOGICAL RECORDS, BUNKERING HALOGEN AND PH TESTING, PRODUCTION HALOGEN MONITORING, AND DISTRIBUTION MICROBIOLOGICAL MONITORING. [NEW VSP OPERATIONS MANUAL 2000 GUIDELINE]
Recommendation: 5.2.1.2.1 A halogen demand test and pH shall be conducted on the shore-side water supply before starting the bunkering process to establish the correct halogen dosage. 5.2.1.2.2 Free residual halogen monitoring shall be performed at least hourly during the bunkering of potable water and performed at least once every 4 hours during the onboard production of potable water. 5.6.1.1.1 A minimum of four potable water samples per month shall be collected and analyzed for the presence of Escherichia coli. Samples shall be collected randomly from locations forward, aft, upper, and lower decks of the vessel. 5.6.1.1.2 Samples shall be analyzed utilizing a method accepted in Standard Methods for the Examination of Water and Wastewater.
Item No.: 09
Site: Other-SWIMMING POOLS
Violation: HALOGEN LEVEL MEASURED FROM 0.6 - 1.1 MG/L (PPM) IN FORWARD SWIMMING POOL.
Recommendation: 6.2.2.1.1 A free residual halogen of >1.0 and <3.0 mg/L (ppm) shall be maintained in recirculated swimming pools.
Item No.: 10
Site: Other-SWIMMING POOLS
Violation: DEVELOP A FECAL ACCIDENT PLAN FOR THE SWIMMING POOLS. ENSURE THAT A SHEPHERD'S HOOK IS INSTALLED AT EACH SWIMMING POOL. [NEW VSP OPERATIONS MANUAL 2000 GUIDELINE]
Recommendation: 6.3.1.2.3 A fecal accident response procedure shall be documented and available to the VSP for review during inspections.
Item No.: 29
Site: Other-BARS
Violation: HANDWASH SINKS WERE NOT INSTALLED IN COUNTER SERVICE AREAS OF BARS. ENSURE PANTRY ACCESS DOOR REMAINS OPEN DURING ALL PERIODS OF SERVICE OR CONVERT ONE OF THE SERVICE COUNTER UTILITY SINKS TO A HANDWASHING STATION WITH SPLASH GUARDS WHERE NEEDED. [NEW VSP OPERATIONS MANUAL 2000 GUIDELINE]
Recommendation: 7.7.1.1.2 The handwashing facility shall be located within 8 m (25 feet) of all parts of the area and should not be located in an adjacent area that requires passage through a closed door. Ensure pantry access door remains open during all periods of service or convert one of the service counter utility sinks to a handwashing station with splash guards where needed.
Item No.: *
Site: Other-GRAND BLEU
Violation: EXCELLENT HOT AND COLD TEMPERATURES WERE NOTED FOR ALL BUFFET ITEMS CHECKED.
Recommendation:
Item No.: 28
Site: Other-GRAND BLEU
Violation: OVEN RACKS WERE STORED ON DECK IN BREAKFAST STORAGE PANTRY.
Recommendation: 7.5.7.3.1 Cleaned equipment and utensils, laundered linens, and single-service and single-use articles shall be stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program