Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seaventure Cruise Line: Polar Latitudes Inspection Date: 08/12/2001 Inspection Score: 94
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 20
Site: Other-DINING ROOM COLD BUFFET
Violation: TRAYS OF MELONS, ROAST DUCK, SALADS, AND CHEESE HAD TEMPERATURES RANGING FROM 50 TO 60°F.
Recommendation: 7.4.3.1.1 Equipment for cooling and heating food, and holding cold and hot food, shall be sufficient in number and capacity to maintain specified potentially hazardous food temperatures.
Item No.: 20
Site: Other-COLD PANTRY
Violation: TWO TRAYS OF SLICED FRUIT IN A REACH-IN REFRIGERATOR WERE 50°F.
Recommendation: 7.4.3.1.1 Equipment for cooling and heating food, and holding cold and hot food, shall be sufficient in number and capacity to maintain specified potentially hazardous food temperatures.
Item No.: 12
Site: Other-MAIN POT WASH
Violation: PERSON HANDLING SOILED EQUIPMENT THEN HANDLED CLEAN EQUIPMENT WITHOUT WASHING HIS HANDS FIRST.
Recommendation: 7.2.3.1.3 Food employees shall clean their hands and exposed portions of their arms immediately before engaging in food preparation including working with exposed food, clean equipment and utensils, and unwrapped single-service and single-use articles and: (1) After touching bare human body parts other than clean hands and clean, exposed portions of arms; (2) After using the toilet room; (3) After coughing, sneezing, using a handkerchief or disposable tissue, using tobacco, eating, or drinking; (4) After handling soiled equipment or utensils; (5) During food preparation, as often as necessary to remove soil and contamination and to prevent cross- contamination when changing tasks; (6) When switching between working with raw food and working with ready-to-eat food; and (7) After engaging in other activities that contaminate the hands.
Item No.: 20
Site: Other-PASTRY PANTRY
Violation: BUTTER AND A CONTAINER OF FRUIT SALAD IN A REACH-IN REFRIGERATOR WERE 50°F.
Recommendation: 7.4.3.1.1 Equipment for cooling and heating food, and holding cold and hot food, shall be sufficient in number and capacity to maintain specified potentially hazardous food temperatures.
Item No.: 24
Site: Other-MAIN DISH WASHING
Violation: THE FINAL RINSE TEMPERATURE OF THE MAIN DISH WASHER WAS 150°F.
Recommendation: 7.5.6.1.2 In a mechanical operation, the temperature of the fresh hot water sanitizing rinse as it enters the manifold may not be more than 90°C (194°F), or less than: (1) For a stationary rack, single temperature machine, 74°C (165°F); or (2) For all other machines, 82°C (180°F). (3) A utensil surface temperature of 71°C (160°F) as measured by an irreversible registering temperature indicator shall be achieved. (4) The maximum temperature of 90°C (194°F), does not apply to the high pressure and temperature systems with wand-type, hand-held, spraying devices used for the in-place cleaning and sanitizing of equipment such as meat saws.
Item No.: 22
Site: Other-MAIN DISH WASHING
Violation: THE DOOR TO THE GLASS WASHER DOES NOT SHUT CORRECTLY.
Recommendation: The door shall be repaired.
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE POTABLE WATER DISTRIBUTION CHARTS HAD A RANGE OF 0.0 TO 2.0 PPM.
Recommendation: 5.5.2.1.1 Halogen analyzer-chart recorder charts shall have a range of 0.0 to 5.0 mg/L (ppm) and have a recording period of 24 hours.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE CHLORINE LEVEL AT THE FAR POINT ANALYZER MEASURED OVER 4.0 PPM DUE TO THE DISTRIBUTION CHLORINE PUMP BEING SET ON MANUAL INSTEAD OF THE AUTOMATIC MODE.
Recommendation: 5.4.1.2.2 The amount of halogen injected into the potable water system shall be controlled by a flow meter or a free halogen analyzer.
Item No.: 10
Site: Other-POOL
Violation: THE CHLORINE CHART RECORDER WAS OUT OF ORDER AND CHLORINE TEST RESULTS WERE NOT BEING RECORDED EVERY 4 HOURS.
Recommendation: 6.2.2.2.2 Residual halogen logs shall be maintained with residuals measured and recorded every 4 hours during operation.
*Inspections scores of 85 or lower are NOT satisfactory