Item No.:
21
|
|
Site:
Other-GALLEY
|
|
Violation:
THERE WERE NON-EASILY CLEANABLE GAPS AROUND AND BETWEEN THE STOVE AND GRILL.
|
|
Recommendation:
7.4.2.2.6
Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Other-GALLEY
|
|
Violation:
THE GAPS AROUND AND BETWEEN THE STOVE AND GRILL WERE SOILED WITH FOOD AND GREASE RESIDUE.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
33
|
|
Site:
Other-FOOD SERVICE-GENERAL
|
|
Violation:
THERE WERE NON-EASILY CLEANABLE GAPS LOCATED IN THE BULKHEADS AND DECKHEADS IN VARIOUS AREAS.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
|
|
|
Item No.:
16
|
|
Site:
Other-DINING ROOM
|
|
Violation:
SLICED MELONS AND A FRUIT SALAD ON THE BUFFET LINE WERE MEASURED AT 56°F. RECOMMEND USING TIME AS A CONTROL.
|
|
Recommendation:
7.3.5.3.1.1
Potentially hazardous food shall be maintained:
(1) At 60°C (140°F) [roasts 54°C (130°F)] or above,; or (2) At 5°C (41°F) or less.
|
|
|
Item No.:
03
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
BUNKERED WATER CHLORINATION SAMPLE POINT WAS NOT 3 METERS FROM THE CHLORINE INJECTION POINT.
|
|
Recommendation:
The sample point shall be at least 3 meters from the chlorine injection point.
|
|
|
Item No.:
06
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
THE MOST RECENT COPY OF THE MICROBIOLOGICAL PORT TESTS WAS NOT AVAILABLE. ALSO, A MINIMUM OF 4 SAMPLES PER MONTH WERE NOT COLLECTED AND ANALYZED.
|
|
Recommendation:
5.1.1.2.1
Where available, the vessel shall have a copy of the most recent microbiologic report from each port before bunkering potable water to verify that the water meets potable standards.
5.6.1.1.1
A minimum of four potable water samples per month shall be collected and analyzed for the presence of Escherichia coli. Samples shall be collected randomly from locations forward, aft, upper, and lower decks of the vessel.
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
A HALOGEN DEMAND AND PH TESTS WERE NOT CONDUCTED ON THE SHORE SIDE WATER BEFORE BUNKERING.
|
|
Recommendation:
5.2.1.2.1
A halogen demand test and pH shall be conducted on the shore-side water supply before starting the bunkering process to establish the correct halogen dosage.
|
|
|
Item No.:
40
|
|
Site:
Other-INTEGRATED PEST MANAGEMENT
|
|
Violation:
A WRITTEN PEST MANAGEMENT PLAN WAS NOT PROVIDED.
|
|
Recommendation:
8.1.1.1.1
Each vessel shall develop an Integrated Pest Management Plan to address effective monitoring and control strategies for pests aboard the vessel.
|
|