Cruise Ship: Nippon Maru Cruise Line: Mitsui O.S.K. Passenger Line, Ltd Inspection Date: 07/03/2003 Inspection Score: 98
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE ANALYZER CHARTS FOR THE DISTRIBUTION SYSTEM DID NOT HAVE A RANGE OF 0-5 PPM. THE ANALYZER CHARTS DID NOT A RECORDING RANGE OF 24 HOURS. THE ANALYZER CHARTS WERE NOT CHANGED DAILY.
Recommendation: 5.5.2.1.1 Halogen analyzer-chart recorder charts shall have a range of 0.0 to 5.0 mg/L (ppm) and have a recording period of 24 hours. 5.5.2.2.1 Halogen analyzer-chart recorder charts shall be changed, initialed, and dated daily. Charts shall contain notations of any unusual water events in the potable water system.
Item No.: 07
Site: Other-POTABLE WATER
Violation: THE RECORDS FOR THE POTABLE WATER TANKS DID NOT SPECIFY THE DISINFECTION CHEMICAL IN PPM OR THE AMOUNT OF TIME FOR DISINFECTION.
Recommendation: 5.3.4.1.4 Disinfection following potential contamination shall be accomplished by increasing free residual halogen to at least 50 mg/L (ppm) throughout the affected area and maintaining this concentration for 4 hours.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE PRESSURE DIFFERENTIAL READINGS FOR THE REDUCED PRESSURE BACFLOW PREVENTION DEVICES WERE NOT RECORDED.
Recommendation: 5.7.2.2.2 Backflow prevention devices requiring testing, for example reduced pressure backflow preventer and double check valves with test cocks, shall be inspected and tested with a test kit at least annually. Test results showing the pressure differences on both sides of the valves shall be maintained for each device. 5.7.2.2.3 The inspection and test results for backflow preventers shall be retained for at least 12 months and shall be available to the VSP for review during inspections.
Item No.: 10
Site: Other-WHIRLPOOL SPAS
Violation: THE FREE CHLORINE RESIDUAL WAS NOT RAISED TO 10 PPM AND CIRCULATED FOR ONE HOUR AT THE END OF THE DAY. THE PH OF THE WHIRLPOOLS WAS NOT CONSISTENTLY MAINTAINED BETWEEN 7.2-7.8 PPM. THE GRANULAR FILTERS WERE NOT INSPECTED MONTHLY FOR CRACKS, MOUNDS, OR HOLES IN THE FILTER MEDIA. A MONTHLY SEDIMENTATION TEST WAS NOT DONE TO CHECK FOR EXCESSIVE ORGANIC MATERIAL. THE CHLORINE RESIDUAL WAS NOT TESTED HOURLY WHILE THE WHIRLPOOLS WERE OPEN FOR USE. THE FECAL ACCIDENT PROCEDURE WAS NOT DETAILED ENOUGH TO DEAL WITH DISINFECTION FOR LOOSE STOOLS. A SAMPLE PROCEDURE WAS PROVIDED TO THE VESSEL.
Recommendation: 6.3.1.1.5 The granular filters shall be opened at least monthly and examined for cracks, mounds, or holes in the filter media. A core sample of the filter media shall be inspected for excessive organic material accumulation using a recommended sedimentation method. 6.3.1.2.2 The whirlpool spa water shall be maintained with a pH between 7.2 and 7.8. 6.3.2.1.1 The free residual halogen shall be increased to at least 10.0 mg/L (ppm) in whirlpool spas and circulated for at least 1 hour at the end of each day. 6.3.2.2.2 Residual halogen logs shall be maintained with residuals measured and recorded hourly during operation. Ensure that the fecal accident procedure properly addresses accidents involving loose stools. The PPM used times the contact time in minutes should be equal to or greater than 9600 for accidents involving loose stools.
Item No.: 09
Site: Other-WHIRLPOOL SPAS
Violation: A REVIEW OF THE LOGS NOTED CHLORINE RESIDUALS OF LESS THAN 3.0 PPM IN THE MEN'S AND WOMEN'S WHIRLPOOL SPAS. THERE WAS NO INDICATION THAT THE WHIRLPOOLS WERE CLOSED WHEN THE READINGS WERE LESS THAN 3.0 PPM
Recommendation: 6.3.2.1.1 Whirlpool spas shall maintain a free residual chlorine of >3.0 mg/L (ppm) and <10 mg/L (ppm), or a free residual bromine of >4.0 mg/L (ppm) and <10 mg/L (ppm).
Item No.: 21
Site: Other-MID-SHIP BAR
Violation: A SEAM WAS NOTED ALONG THE BOTTOM LEFT PANEL AT THE COFFEE MACHINE.
Recommendation: 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 36
Site: Other-MID-SHIP BAR
Violation: THE LIGHT BULB IN THE LEFT REFRIGERATION UNIT WAS NOT SHIELDED OR SHATTER-RESISTANT.
Recommendation: 7.7.5.2.1 Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service, and single-use articles.
Item No.: 36
Site: Other-NEPTUNE BAR
Violation: THE LIGHT BULB IN THE REFRIGERATION UNIT WAS NOT SHIELDED OR SHATTER-RESISTANT.
Recommendation: 7.7.5.2.1 Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service, and single-use articles.
Item No.: 21
Site: Other-DOLPHIN HALL BAR
Violation: THE WOODEN SHELVING MATERIAL WAS NOT SEALED.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 36
Site: Other-DOLPHIN HALL BAR
Violation: THE OVERHEAD LIGHT BULBS WERE NOT SHIELDED OR SHATTER-RESISTANT.
Recommendation: 7.7.5.2.1 Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service, and single-use articles.
Item No.: 22
Site: Other-DOLPHIN HALL BAR
Violation: THE WAREWASH UNIT WAS OUT OF ORDER.
Recommendation: Repair or replace this unit.
Item No.: 22
Site: Other-BARS GENERAL
Violation: DATA PLATES WERE NOT PROVIDED FOR THE WAREWASH UNITS.
Recommendation: 7.5.2.2.3 A warewashing machine shall be provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: NIPPON MARU- CAS - [07/03/2003] .
Recommendation:
Item No.: 30
Site: Other-MAIN GALLEY - BUS STATION
Violation: A "WASH HANDS OFTEN" SIGN WAS NOT POSTED AT THE HANDWASH SINK.
Recommendation: 7.7.1.1.7 A sign stating "WASH HANDS OFTEN" in a language that the food employees understand shall be posted over handwashing sinks.
Item No.: 31
Site: Other-MAIN GALLEY - BUS STATION
Violation: A CONTAINER OF ALCOHOL HAND SANITIZER WAS STORED IN THE DINING LOCKER LINEN CLOSET.
Recommendation: 7.6.2.1.2 Poisonous or toxic materials used in food area cleaning and maintenance shall be stored so they cannot contaminate food, equipment, utensils, linens, and single-service and single-use articles by separating the poisonous or toxic materials by storing in a cleaning materials locker.
Item No.: 36
Site: Other-MAIN GALLEY - DRINK SERVICE STATION
Violation: TWO OVERHEAD LIGHT BULBS WERE NOT SHIELDED.
Recommendation: 7.7.5.2.1 Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service, and single-use articles.
Item No.: 27
Site: Other-MAIN GALLEY - DRINK SERVICE STATION
Violation: TWO PREVIOUSLY CLEANED SOUP CONTAINERS WERE SOILED ON THE NON-FOOD CONTACT SURFACES.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Other-MAIN GALLEY - DRINK SERVICE STATION
Violation: SEVERAL LARGE SERVING TRAYS WERE FRAYED ALONG THE EDGES MAKING THE SURFACES NOT EASILY CLEANABLE.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 33
Site: Other-MAIN PANTRY
Violation: A CRACKED TILE WAS NOTED ON THE COVING UNDER THE HANDWASH SINK ADJACENT TO THE PANTRY LOCKER.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 26
Site: Other-MAIN PANTRY
Violation: ONE PREVIOUSLY CLEANED SOUP LADLE WAS SOILED WITH FOOD DEBRIS.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 37
Site: Other-MAIN GALLEY - WAREWASH AREA
Violation: EXCESS CONDENSATE WAS NOTED ON THE DECKHEAD ABOVE THE WAREWASH MACHINE. WATER WAS DRIPPING BACK ONTO TO THE SURFACE OF THE MACHINE.
Recommendation: 7.7.6.1.1 All food preparation, warewashing, and toilet rooms shall have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item No.: 26
Site: Other-MAIN GALLEY - PASTRY AREA
Violation: ONE PREVIOUSLY CLEANED PAN WAS NOTED STORED WITH LABEL REMNANTS ATTACHED TO THE COOKING SURFACE.
Recommendation: Remove the label residue from the pan.
Item No.: 30
Site: Other-GARBAGE ROOM
Violation: A "WASH HANDS OFTEN" SIGN WAS NOT POSTED OVER THE HANDWASH SINK.
Recommendation: 7.7.1.1.7 A sign stating "WASH HANDS OFTEN" in a language that the food employees understand shall be posted over handwashing sinks.
Item No.: 29
Site: Other-GARBAGE ROOM
Violation: A GARBAGE CAN FILLED WITH FOOD SCRAPS WAS NOTED PARTIALLY BLOCKING THE HANDWASH SINK.
Recommendation: 7.7.1.3.1 Handwashing facilities shall be used for no other purpose and shall be accessible at all times.
Item No.: 08
Site: Other-GARBAGE ROOM
Violation: A DECK TAP WAS NOTED WITH A HOSE ATTACHED WITHOUT A BACKFLOW PREVENTION DEVICE INSTALLED.
Recommendation: 5.7.1.2.1 Backflow preventers shall be installed when air gaps are impractical or when water under pressure is required.
Item No.: *
Site: Other-HOUSEKEEPING
Violation: IT IS RECOMMENDED THAT THE MEDICAL STAFF AND HOUSEKEEPING MANAGER COORDINATE WITH THE CORPORATE OFFICE TO ESTABLISH PROPER DISINFECTION PROCEDURES DURING OUTBREAKS.
Recommendation: