Item No.:
19
|
|
Site:
Other-MARINA - BUFFET
|
|
Violation:
THREE SMALL PLATES OF MIXED BREAD AND PASTRY ITEMS ON THE BUFFET LINE WERE POSITIONED OUTSIDE OF THE SNEEZE SHIELD AND WERE EXPOSED TO PASSENGER CONTAMINATION. THE PLATES WERE MOVED IMMEDIATELY.
|
|
Recommendation:
7.3.3.6.1
Food on display shall be protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
|
|
|
Item No.:
34
|
|
Site:
Other-MARINA GALLEY
|
|
Violation:
THE WATER FAUCETS WERE NOT WORKING CORRECTLY (TURNING ON AND ADJUSTMENT OF WATER TEMPERATURE) AT THE DOUBLE BASIN HANDWASH STATION. THIS WAS CORRECTED IMMEDIATELY.
|
|
Recommendation:
7.7.3.3.1
A plumbing system in a food area shall be maintained in good repair.
|
|
|
Item No.:
22
|
|
Site:
Other-MARINA GALLEY - DISHWASH
|
|
Violation:
THE FINAL RINSE GAUGE TEMPERATURE ON THE IN-USE GLASSWASH MACHINE WAS OVER 10 °F OUT OF CALIBRATION AS COMPARED TO THE DISH LEVEL TEMPERATURE. THE CONVEYOR DISHWASH MACHINE HAD A FINAL RINSE GAUGE TEMPERATURE WHICH WAS OVER 20 °F OUT OF CALIBRATION WITH THE DISH LEVEL TEMPERATURE.
|
|
Recommendation:
7.5.4.1.1
Warewashing equipment shall be maintained in good repair and proper adjustment including:
(1) Warewashing equipment shall be maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines. (2) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
|
|
|
Item No.:
22
|
|
Site:
Other-MARINA GALLEY - DISHWASH
|
|
Violation:
THE DISH LEVEL TEMPERATURE IN THE HOT WATER SANITIZING COMPARTMENT OF THE IN-USE CONVEYOR DISHWASH MACHINE WAS 155-160 °F IN REPEATED TESTING.
|
|
Recommendation:
7.5.4.1.3
A warewashing machine and its auxiliary components:
(1) Shall be operated in accordance with the machine's data plate and other manufacturer's instructions.
|
|
|
Item No.:
21
|
|
Site:
Other-MARINA BUFFET
|
|
Violation:
POWER CORDS TO COUNTER MOUNTED EQUIPMENT WERE DRAPING THE COUNTER TOPS AND PILING ON THE DECK BELOW, MAKING BOTH AREAS MORE DIFFICULT TO CLEAN. BOTH THE COUNTERS AND THE DECK WERE CLEAN.
|
|
Recommendation:
Attempt to control these cables and bundle them with ties to keep of the deck and counter tops. Seek a long term solution through construction if this operation becomes permanent.
|
|
|
Item No.:
22
|
|
Site:
Other-CREW GALLEY - DISHWASH
|
|
Violation:
THE FINAL RINSE GAUGE TEMPERATURE OF THE INE-USE CONVEYOR DISHWASH MACHINE WAS OVER 15 °F OUT OF CALIBRATION, BASED ON THE DISH LEVEL TEMPERATURE.
|
|
Recommendation:
7.5.4.1.1
Warewashing equipment shall be maintained in good repair and proper adjustment including:
(1) Warewashing equipment shall be maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines. (2) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
|
|
|
Item No.:
22
|
|
Site:
Other-CREW GALLEY - POT WASH
|
|
Violation:
THE HOT WATER SANITIZING SINK HAD A WATER TEMPERATURE OF 180 °F, WHILE THE MOUNTED THERMOMETER REGISTERED 198 °F.
|
|
Recommendation:
7.5.4.1.1
Warewashing equipment shall be maintained in good repair and proper adjustment including:
(1) Warewashing equipment shall be maintained in a state of repair and condition that meets the standards of the materials, design, and construction of these guidelines. (2) Water pressure, and water temperature measuring devices shall be maintained in good repair and be accurate within the intended range of use.
|
|
|
Item No.:
34
|
|
Site:
Other-CREW GALLEY - HOT GALLEY
|
|
Violation:
WASTEWATER WAS DRAINING FROM THE BASE OF THE LARGE COMBINATION OVEN AND PONDING ON THE DECK SURROUNDING. THE DRAIN PLUG WAS MISSING FROM THE BASE OF THE OVEN.
|
|
Recommendation:
7.7.3.3.1
A plumbing system in a food area shall be maintained in good repair.
|
|
|
Item No.:
*
|
|
Site:
Other-COMMENT
|
|
Violation:
MANAGEMENT AND RECORDKEEPING IN THE POTABLE WATER, POOLS, AND VENTILATION PROGRAMS WAS VERY STRONG. MANAGEMENT AND PRACTICES IN FOOD OPERATIONS AND PROVISIONS WAS ALSO EXCELLENT TODAY.
|
|
Recommendation:
|
|
|
Item No.:
*
|
|
Site:
Other-COMMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
|
|
Recommendation:
|
|
|
Item No.:
21
|
|
Site:
Other-TIDES GALLEY
|
|
Violation:
ELECTRICAL CORDS FOR THE PORTABLE INDUCTION COOK TOPS WERE LAYING ACROSS FOOD SERVICE COUNTER-TOPS
|
|
Recommendation:
Shorten cords or bundle them with plastic ties and hang so they don't drape counters and inhibit access for easy cleaining. A long term soludion would be to install utility connections either on top of the counters or in positions in side the counter base to faciliate more sanitary operation of the power cables.
|
|
|
Item No.:
40
|
|
Site:
Other-INTEGRATED PEST MANAGEMENT
|
|
Violation:
THE IPM DID NOT INCLUDE DOCUMENTATION OF TRAINING OR CERTIFICATION OF ALL PERSONNEL INVOLVED IN PEST MANAGEMENT
|
|
Recommendation:
8.1.2.1.3
The training of the pest-control personnel shall be documented in the Integrated Pest Management Plan.
|
|