Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Safari Quest Cruise Line: Un-Cruise Adventures Inspection Date: 09/06/2003 Inspection Score: 81
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 26
Site: Other-GALLEY
Violation: THE MIXER COLLAR AND FOOD SPLASH AREAS WERE SOILED WITH DRIED FOOD DEBRIS. PREVIOUSLY CLEANED ITEMS STORED AS CLEAN WERE FOUND SOILED WITH FOOD DEBRIS AS FOLLOWS: 2 SHEET PANS, THE BLENDER BLADE AND GASKET, AND NUMEROUS UTENSILS. THE INTERIOR SURFACES OF THE OVENS WERE SOILED.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized. 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 21
Site: Other-GALLEY
Violation: CHIPPED PAINT WAS NOTED ON THE SHELVING AND INTERIOR DRAWERS MAKING THESE AREAS DIFFICULT TO CLEAN. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 20
Site: Other-GALLEY
Violation: THE IMMERSION BLENDER PROBE WAS CRACKED MAKING IT DIFFICULT TO CLEAN. LIQUID WAS RETAINED WITHIN THE CRACK OF THE BLENDER . THIS WAS DISCARDED DURING THE INSPECTION.
Recommendation: 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 27
Site: Other-GALLEY
Violation: THE CARDBOARD ALUMINUM FOIL DISPENSER WAS SOILED WITH GREASE AND FOOD DEBRIS.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Other-GALLEY
Violation: THE CARDBOARD ALUMINUM FOIL DISPENSER COULD NOT BE EASILY CLEANED.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 26
Site: Other-BAR
Violation: THE CUBER AND WATER SUPPLY LINE HOSES OF THE ICE MACHINE WERE SOILED WITH MOLD.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 19
Site: Other-PROVISIONS
Violation: CARDBOARD BOXES OF JUICES, BOTTLED WATER AND NAPKINS WERE STORED ON THE DECK. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 7.3.3.5.1 Food shall be protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 33
Site: Other-PROVISIONS
Violation: MOLD WAS NOTED ON THE BULKHEADS OF THE DRY STORES AREA. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 7.7.4.2.1 Decks, bulkheads, deckheads, and attached equipment in food preparation, warewashing, pantries, and storage areas, shall be cleaned as often as necessary.
Item No.: 40
Site: Other-GALLEY
Violation: THE GALLEY EXIT DOOR WAS UNSCREENED, ALLOWING ENTRY OF PESTS. THE DOOR WAS OPEN AT THE TIME OF THE INSPECTION. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 8.2.1.1.2 Entry points where pests may enter the food areas shall be protected.
Item No.: 20
Site: Other-GALLEY
Violation: THE FOOD CONTACT SURFACES OF EQUIPMENT WERE DIFFICULT TO CLEAN DUE TO GAPS, OPEN SEAMS, EXPOSED COILS AND OTHER FEATURES. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 33
Site: Other-GALLEY/BAR
Violation: THE DECK WAS SOILED UNDER EQUIPMENT. INSTALLATION OF THE EQUIPMENT DID NOT PROVIDE SUFFICIENT SPACE FOR CLEANING. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 7.4.4.1.1 Equipment that is fixed because it is not easily movable shall be installed so that it is: (1) Spaced to allow access for cleaning along the sides, behind, under and above the equipment; (2) Spaced from adjoining equipment, bulkhead, and deckhead at a distance of not more than 1 millimeter or 1/32 inch; or (3) Sealed to adjoining equipment or bulkhead, if the equipment is exposed to spillage or seepage.
Item No.: 33
Site: Other-PROVISIONS
Violation: A PORTION OF THE DECKHEAD WAS CONSTRUCTED OF PARTIALLY PAINTED PARTICLE BOARD THAT CONTAINED GAPS AND OPEN SEAMS AND WAS NOT EASILY CLEANABLE. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 7.7.4.1.8 Surfaces subject to routine splashes, spillage or other soiling during normal use shall have easily cleanable features.
Item No.: 36
Site: Other-PROVISIONS
Violation: THE ARTIFICAL LIGHT LEVEL IN THE PROVISIONS DRY STORES AREA WAS NOT SUFFICIENT FOR CLEANING. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 7.7.5.1.2 The light intensity shall be at least 110 Lux (10 foot candles) at a distance of 75 centimeters (30 inches) above the deck when in use, in walk-in refrigerator units and dry storage areas, and in other areas and rooms during periods of cleaning.
Item No.: 26
Site: Other-BAR
Violation: A VENTED BACKFLOW PREVENTION DEVICE WAS PROVIDED ON THE CARBONATOR. THIS WAS NOTED ON THE LAST INSPECTION. BRASS FITTING WERE NOTED ON THE WATER INLET TO THE CARBONATOR.
Recommendation: 7.4.1.1.5 Copper and copper alloys such as brass: (1) May not be used in contact with a food that has a pH below 6 such as vinegar, fruit juice, or wine or for a fitting or tubing installed between a backflow prevention device and a carbonator. 5.7.1.2.1 Backflow preventers shall be installed when air gaps are impractical or when water under pressure is required.
Item No.: 40
Site: Other-PEST MANAGEMENT
Violation: THE VESSEL DOES NOT HAVE AN INTEGRATED PEST MANAGEMENT PLAN. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 8.1.1.2.3 The vessel's Integrated Pest Management Plan documentation shall be made available during the VSP inspections. 8.1.1.1.2 The Integrated Pest Management Plan shall set a schedule for periodic monitoring inspections including some at night. 8.1.1.1.3 The Integrated Pest Management Plan shall include provisions for active monitoring including pest sighting logs for the operational areas of the vessel and training for crew members in charge of log completion. 8.1.1.1.4 The Integrated Pest Management Plan shall include passive surveillance procedures such as glue traps and other monitoring tools, as well as location of each. A monitoring log on passive surveillance procedures shall be maintained. 8.1.1.2.1 The vessel's Integrated Pest Management Plan shall be evaluated for effectiveness every 2 years or whenever there is a significant change in the vessel's structure such as a renovation or operation. 8.1.2.1.1 The Integrated Pest Management Plan shall include a record of pesticides used and their effectiveness. 8.1.2.1.3 The training of the pest-control personnel shall be documented in the Integrated Pest Management Plan. 8.1.2.1.4 The Integrated Pest Management Plan shall establish health and safety procedures to protect the passengers and crew. 8.2.1.1.3 Incoming shipments of food and supplies shall be routinely inspected for evidence of insects, rodents, and other pests.
Item No.: 21
Site: Other-GALLEY
Violation: THE NON-FOOD CONTACT SURFACES OF EQUIPMENT AND SHELVING WERE DIFFICULT TO CLEAN DUE TO OPEN SEAMS AND GAPS. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE DISTRIBUTION SAMPLE SITE WAS LESS THEN TEN FEET (3 M) FROM THE HALOGEN INJECTION POINT.
Recommendation: 5.2.1.2.7 Water samples for halogen testing shall be obtained from a sample cock located on the bunker or production water line at least 3 m (10 feet) after the halogen injection point and before the storage tank.
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE VESSEL DID NOT HAVE THE MOST RECENT MICROBIOLOGIC REPORT FROM EACH PORT WHERE WATER WAS BUNKERED. FOUR POTABLE WATER SAMPLES WERE NOT COLLECTED FROM THE DISTRIBUTION SYSTEM EACH MONTH AND ANALYZED FOR THE PRESENCE OF E. COLI. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 5.1.1.2.1 Where available, the vessel shall have a copy of the most recent microbiologic report from each port before bunkering potable water to verify that the water meets potable standards. 5.6.1.1.1 A minimum of four potable water samples per month shall be collected and analyzed for the presence of Escherichia coli. Samples shall be collected randomly from locations forward, aft, upper, and lower decks of the vessel.
Item No.: 04
Site: Other-POTABLE WATER
Violation: THE FREE CHLORINE RESIDUAL IN THE DISTRIBUTION SYSTEM WAS BETWEEN 6 PPM AND 12 PPM ON SEVERAL DATES WITHOUT CORRECTIVE ACTIONS NOTED. (JULY 21-8 HRS-8 PPM; JUNE 28-8 HRS-BETWEEN 6-12 PPM; JUNE 27-20 HRS-BETWEEN 6-8 PPM)
Recommendation: 5.4.1.2.1 The halogenation device shall provide continuous halogenation of the potable water distribution system and shall maintain a free residual halogen of greater or equal to 0.2 mg/L (ppm) and less than or equal to 5.0 mg/L (ppm) throughout the distribution system.
Item No.: 06
Site: Other-POTABLE WATER
Violation: SEVERAL DISTRIBUTION CHARTS WERE NOT DATED.
Recommendation: 5.5.2.2.1 Halogen analyzer-chart recorder charts shall be changed, initialed, and dated daily. Charts shall contain notations of any unusual water events in the potable water system.
Item No.: 08
Site: Other-POTABLE WATER
Violation: DOCUMENTATION THAT THE POTABLE WATER TANKS HAD BEEN CLEANED AND DISINFECTED WAS NOT AVAILABLE. SAMPLE VALVES WERE NOT AVAILABLE ON THE POTABLE WATER TANKS. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 5.3.4.1.2 Potable water tanks shall be inspected, cleaned, and disinfected during dry docks and wet docks, or every 2 years, whichever is less. 5.3.4.1.3 Documentation of the cleaning shall be maintained for 12 months and shall be available to the VSP for review during inspections. 5.3.1.2.2 Potable water tanks shall have sample valves which are turned down.
Item No.: 08
Site: Other-CROSS-CONNECTION CONTROL PLAN
Violation: THE VESSEL DID NOT HAVE A CROSS-CONNECTION CONTROL PROGRAM. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems. 5.7.2.2.3 The inspection and test results for backflow preventers shall be retained for at least 12 months and shall be available to the VSP for review during inspections. 5.7.2.2.2 Backflow prevention devices requiring testing, for example reduced pressure backflow preventer and double check valves with test cocks, shall be inspected and tested with a test kit at least annually. Test results showing the pressure differences on both sides of the valves shall be maintained for each device. 5.7.2.2.1 Backflow prevention devices should be periodically inspected and any failed units shall be replaced.
Item No.: 07
Site: Other-POTABLE WATER
Violation: THE VESSEL DID NOT HAVE A COPY OF THE VARIANCE REQUEST FOR POTABLE WATER TANKS THAT SHARE A WALL IN COMMON WITH THE HULL OF THE VESSEL. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 5.3.1.1.1 Potable water tanks shall not share a common wall with the hull of the vessel or with tanks containing non-potable water or other liquids. Ensure that the variance process is completed. Have available on the vessel the appropriate documentation for the variance request. Install the appropriate equipment for analyzing salinity levels. Install alarms should saltwater incursion result from a breach in the hull.
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE DISTRIBUTION SYSTEM DID NOT HAVE A BACK-UP HALOGEN PUMP WITH AN AUTOMATIC SWITCHOVER SHOULD THE PRIMARY PUMP FAIL. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 5.4.1.2.3 At least one backup halogen pump shall be available with automatic switchover to maintain the free residual halogen in the event that the primary pump fails.
Item No.: 10
Site: Other-SPA
Violation: THE FREE CHLORINE RESIDUAL WAS NOT RAISED TO 10PPM AND CIRCULATED FOR ONE HOUR AT THE END OF EACH DAY. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 6.3.2.1.1 The free residual halogen shall be increased to at least 10.0 mg/L (ppm) in whirlpool spas and circulated for at least 1 hour at the end of each day.
Item No.: 10
Site: Other-SPA
Violation: THE SPA WAS NOT DRAINED DAILY. THIS WAS NOTED ON THE LAST INSPECTION. A VARIANCE REQUEST HAS BEEN SUBMITTED FOR THIS REQUIREMENT.
Recommendation: 6.3.1.2.1 The whirlpool spa water shall be changed daily.
Item No.: 10
Site: Other-SPA
Violation: THE SPA WATER IS NOT TESTED FOR PH. IT COULD NOT BE VERIFIED THAT THE PH IN THE SPA WAS MAINTAINED BETWEEN 7.2-7.8.
Recommendation: 6.3.1.2.2 The whirlpool spa water shall be maintained with a pH between 7.2 and 7.8.
Item No.: 10
Site: Other-SPA RECORDS
Violation: NUMEROUS CHARTS WERE NOT DATED.
Recommendation: 6.3.2.3.5 Halogen analyzer-chart recorder charts shall be initialed, dated and changed daily.
Item No.: 09
Site: Other-SPA
Violation: FROM JUNE 27TH THROUGH SEPTEMBER 5TH THE CHLORINE RESIDUAL WAS BELOW 3 PPM FROM 4 HOURS AND UP TO 24 HOURS. CORRECTIVE ACTIONS WERE NOT DOCUMENTED.
Recommendation: 6.3.2.1.1 Whirlpool spas shall maintain a free residual chlorine of >3.0 mg/L (ppm) and <10 mg/L (ppm), or a free residual bromine of >4.0 mg/L (ppm) and <10 mg/L (ppm).
Item No.: 10
Site: Other-SPA
Violation: A FECAL ACCIDENT PLAN WAS NOT AVAILABLE FOR THE SPA. A SIGN WARNING IMMUNOCOMPROMISED INDIVIDUALS OF THE INCREASED HEALTH RISKS ASSOCIATED WITH USING THE SPA WAS NOT AVAILABLE.
Recommendation: 6.1.2.2.2 A fecal accident response procedure shall be documented and available for review during inspections. 6.4.1.1.3 A sign shall be installed near the whirlpool spas that lists standard safety precautions and risks, warning against use by particularly susceptible people, such as those who are immunocompromised.
Item No.: 41
Site: Other-VENTILATION
Violation: THE AIR CONDITIONING CONDENSATE COLLECTION PANS DID NOT DRAIN COMPLETELY AND A MOLDY SCUM RESIDUE WAS NOTED IN THE DRAIN PANS.
Recommendation: 9.2.1.1.2 Air condition condensation collection pans shall be self-draining. 9.2.1.2.1 Air handling units shall be kept clean.
Item No.: 33
Site: Other-FOOD SERVICE GENERAL
Violation: THE DECKS, DECKHEADS, AND BULKHEADS WERE DIFFICULT TO CLEAN DUE TO GAPS, CREVICES AND OPEN SEAMS. THIS WAS NOTED ON THE LAST INSPECTION.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 28
Site: Other-GALLEY
Violation: THE CRACKED HOUSING OF THE IMMERSION BLENDER PROBE HAD LEAKED DEBRIS AND LIQUID FROM THE CRACK ONTO THE UTENSILS STORED IN THE SAME DRAWER
Recommendation: 7.5.7.3.1 Cleaned equipment and utensils, laundered linens, and single-service and single-use articles shall be stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SAFARI QUEST- CAS - [ INSPECTION DATE 09/06/2003].
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program