Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Seven Seas Mariner Cruise Line: Regent Seven Seas Inspection Date: 02/24/2004 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 33
Site: Other-MAIN GALLEY
Violation: SOME TILES HAD MISSING GROUT MAKING CLEANING DIFFICULT.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 37
Site: Other-CREW GALLEY
Violation: HEAVY CONDENSATION WAS NOTED ON THE DECKHEAD OVER THE RATH - OVENS.
Recommendation: 7.4.3.2.1 Ventilation hood systems and devices shall be sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
Item No.: 05
Site: Other-POTABLE WATER
Violation: THE FAR POINT HALOGEN ANALYZER READ 0.53 PPM AND THE MANUAL TEST READ 0.97. IT WAS STATED THAT THE ANALYZER HAD BEEN CHECKED AND THE CALIBRATION ADJUSTED EARLIER IN THE MORNING.
Recommendation: 5.5.1.2.3 The free residual halogen measured by the halogen analyzer shall be ±0.2 mg/L (ppm) of the free residual halogen measured by the manual test.
Item No.: 22
Site: Other-CAFÉ GALLEY / DISHWASH
Violation: THE DATA PLATE ON THE HOOD TYPE DISHWASHING MACHINE STATED A FINAL RINSE TIME OF 11 SECONDS. IT DID NOT APPEAR THAT THE FINAL RINSE RAN FOR THE FULL 11 SECONDS. THE TEMPERATURE OF THE UNIT DID REACH A FINAL TEMPERATURE OF AT LEAST 160°F. IT WAS STATED THAT THE DISHWASHING MACHINE HAD VARIABLE SETTINGS FOR EITHER PLATES OR GLASSES AND THAT THE PLATE FINAL RINSE TIME WAS 11 SECONDS BUT THE GLASS FINAL RINSE WAS LESS THAN 11 SECONDS. THIS WAS NOT INDICATED ON THE DATA PLATE AND THERE WAS NO INDICATION ON THE OPERATING SELECTOR TO INDICATE THE CORRECT TIME FOR EACH TYPE OF DISH.
Recommendation: Ensure that the data plate accurately reflects the operations of the dishwashing machine.
Item No.: 37
Site: Other-MAIN GALLEY-WARE WASHER
Violation: A SMALL BUILDUP OF CONDENSATION WAS NOTED ON THE DECKHEAD OVER THE CLEAN END OF THE WAREWASHER.
Recommendation: 7.4.3.2.1 Ventilation hood systems and devices shall be sufficient in number and capacity to prevent grease or condensation from collecting on bulkheads and deckheads.
Item No.: 37
Site: Other-CREW GALLEY
Violation: HEAVY CONDENSATION WAS NOTED ON THE DECKHEAD OVER THE WAREWASHER.
Recommendation: 7.7.6.1.1 All food preparation, warewashing, and toilet rooms shall have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke, and fumes.
Item No.: 08
Site: Other-POTABLE WATER
Violation: SEVERAL OF THE POTABLE WATER BUNKER HOSES WERE NOT CAPPED OR COUPLED TOGETHER. ALL OF THE HOSES IN THE STORAGE LOCKER HAD ALUMINUM FOIL COVERING THE ENDS.
Recommendation: Store all potable water hoses either capped or coupled together. The aluminum foil is to thin to provide a good protective cover.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program