|
|
|
Item No.:
19
|
|
Site:
Other-CREW MESS BUFFET LINE
|
|
Violation:
THE SNEEZE SHIELD DID NOT PROTECT THE FOOD STORED BENEATH ON THE END OF THE BUFFET LINE.
|
|
Recommendation:
7.3.3.6.1
Food on display shall be protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
|
|
|
Item No.:
21
|
|
Site:
Other-BAKERY
|
|
Violation:
THE FLOOR MIXER PROBE LEAKED OIL . IT COULD NOT BE DETERMINED IF THE OIL WAS FOOD GRADE.
|
|
Recommendation:
7.4.2.4.4
Equipment containing bearings and gears that require lubricants shall be designed and constructed so that the lubricant cannot leak, drip, or be forced into food or onto food-contact surfaces.
Recommend that a food grade oil be obtained and used on all mixers where the potential for the oil to drip into the food exists.
|
|
|
Item No.:
26
|
|
Site:
Other-BAKERY
|
|
Violation:
THE PREVIOUSLY CLEANED FLOOR MIXER COLLAR AND FOOD SPLASH ZONE WERE SOILED WITH DRIED FOOD DEBRIS.
|
|
Recommendation:
7.3.3.4.1
Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
26
|
|
Site:
Other-BAKERY
|
|
Violation:
THE PREVIOUSLY CLEANED PORTABLE MIXER'S FOOD SPLASH ZONE AND COLLAR WERE SOILED WITH A STICKY RESIDUE.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
34
|
|
Site:
Other-PROVISIONS
|
|
Violation:
THE VEGETABLE WALK-IN REFRIGERATION UNIT'S CONDENSER DRAIN LEAKED.
|
|
Recommendation:
7.7.3.3.1
A plumbing system in a food area shall be maintained in good repair.
|
|
|
Item No.:
33
|
|
Site:
Other-PROVISIONS-VEGETABLE FREEZER
|
|
Violation:
THE BULKHEAD LIGHT FIXTURE CONTAINED FROZEN LIQUID FROM CONDENSATE FROM THE BULKHEAD.
|
|
Recommendation:
7.7.4.2.3
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
|
|
|
Item No.:
*
|
|
Site:
Other-COMMENT
|
|
Violation:
NUMEROUS PREVIOUSLY CLEANED ITEMS WERE SOILED IN THE GALLEY AND DISHWASH AREAS. POSSIBLY ADDITIONAL LIGHTING MAY NEED TO BE PROVIDED OVER THE POTWASH SINKS.
|
|
Recommendation:
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
THE REDUCED PRESSURE ASSEMBLY BACKFLOW PREVENTERS ON THE INTERNATIONAL SHORE CONNECTIONS HAVE NOT BEEN PERMANTLEY INSTALLED OR TESTED.
|
|
Recommendation:
5.7.1.2.1
Backflow preventers shall be installed when air gaps are impractical or when water under pressure is required.
|
|
|
Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME: SEA DREAM II - CAS - [INSPECTION DATE: 04/11/2004] .
|
|
Recommendation:
|
|
|
Item No.:
22
|
|
Site:
Other-LIDO
|
|
Violation:
THE DATA PLATE WAS MISSING FROM THE DISHWASH MACHINE.
|
|
Recommendation:
7.5.2.2.3
A warewashing machine shall be provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the:
(1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
|
|
|
Item No.:
19
|
|
Site:
Other-LIDO
|
|
Violation:
THE CONTAINERS OF BREAD ON THE TOP OF THE SNEEZE SHIELD WAS NOT PROTECTED FROM SNEEZES AND COUGHS.
|
|
Recommendation:
7.3.3.6.1
Food on display shall be protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
|
|
|
Item No.:
08
|
|
Site:
Other-LIDO
|
|
Violation:
THE GLASSWASH BACKFLOW PREVENTION DEVICE WAS SEVERELY CORRODED AND MAY NEED TO BE REPLACED.
|
|
Recommendation:
5.7.2.2.1
Backflow prevention devices should be periodically inspected and any failed units shall be replaced.
|
|
|
Item No.:
20
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
THE ICE MACHINES FOOD CONTACT SURFACES WERE CORRODED IN THE CUBER AND BIN AREAS AND AN ABSORBENT GASKET/SEALANT WAS NOTED BETWEEN THE CUBER AND BIN. THE CORROSION BETWEEN THE BIN AND CUBER WAS SO SEVERE THAT THE ICE INSIDE THE BIN WAS NOT PROTECTED FROM POTENTIAL CONTAMINATION FROM THE EXTERIOR OF THE MACHINE. PER THE DOCTOR MOST OF THE BACTERIOLOGICAL POSITIVE WATER SAMPLES WERE FROM THE ICE MACHINES.
|
|
Recommendation:
7.4.1.1.2
Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be:
(1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
30
|
|
Site:
Other-MAIN BAR
|
|
Violation:
THE 'WASH HANDS OFTEN" SIGN WAS MISSING FROM THE HANDWASH SINK.
|
|
Recommendation:
7.7.1.1.7
A sign stating "WASH HANDS OFTEN" in a language that the food employees understand shall be posted over handwashing sinks.
|
|
|
Item No.:
20
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
THE GASKETS WERE MISSING FROM THE BAR BLENDERS. LIQUID LEAKED FROM THE BASE OF THE BLENDERS WHEN FILLED WITH WATER.
|
|
Recommendation:
7.4.5.1.1.1
Food-contact equipment shall be maintained in good repair and proper adjustment including:
(1) Equipment shall be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
|
|
|
Item No.:
33
|
|
Site:
Other-POOL BAR
|
|
Violation:
THE FIRE EXTINGUISHER WAS STORED ON THE DECK MAKING THE AREA DIFFICULT TO CLEAN.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
|
|
|
Item No.:
34
|
|
Site:
Other-POOL BAR
|
|
Violation:
THE REACH-IN REFRIGERATION UNIT CONDENSER DRAIN LEAKED.
|
|
Recommendation:
7.7.3.3.1
A plumbing system in a food area shall be maintained in good repair.
|
|
|
Item No.:
26
|
|
Site:
Other-COLD KITCHEN
|
|
Violation:
THE PREVIOUSLY CLEANED BACK GUARD AND BLADE OF THE SLICER WERE SOILED.
|
|
Recommendation:
7.3.3.4.1
Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
20
|
|
Site:
Other-COLD KITCHEN
|
|
Violation:
GAPS WERE NOTED ON THE BACK GUARD OF THE SLICER, MAKING IT DIFFICULT TO CLEAN.
|
|
Recommendation:
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
34
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
THE CONDENSER DRAIN LEAKED IN REFRIGERATION UNIT # 4.
|
|
Recommendation:
7.7.3.3.1
A plumbing system in a food area shall be maintained in good repair.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
THE PREVIOUSLY CLEANED LIFTING PAN WAS SOILED WITH DRIED FOOD DEBRIS.
|
|
Recommendation:
7.3.3.4.1
Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
THE PREVIOUSLY CLEANED FRYER COILS WERE SOILED WITH ENCRUSTED BURNT ON GREASE.
|
|
Recommendation:
7.5.5.1.2
The food-contact surfaces of cooking equipment and pans shall be kept free of encrusted grease deposits and other soil accumulations.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
THE PREVIOUSLY CLEANED; STEAM KETTLE, LARGE COOKING PANS, HAND MIXER BLADE AND CUTTING BOARDS WERE SOILED.
|
|
Recommendation:
7.3.3.4.1
Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
20
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
TWO CUTTING BOARDS CONTAINED GOUGES MAKING THEM DIFFICULT TO CLEAN.
|
|
Recommendation:
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY POTWASH
|
|
Violation:
CLEAN UTENSILS, LADLES AND 4 INCH PANS WERE STORED DIRECTLY BEHIND THE WASH SINK OF THE THREE COMPARTMENT SINKS. THESE CLEAN UTENSILS AND EQUIPMENT WERE STORED ON THE DIRTY SIDE OF THE SHEILD AND POTWASH AREA. THIS WAS NOTED DURING THE LAST INSPECTION AND THE VESSEL INSTALLED A SHIELD ON THE CLEAN DISHWARE SHELF BEHIND THE WASH SECTION OF THE THREE COMPARTMENT SINK.
|
|
Recommendation:
7.5.7.3.1
Cleaned equipment and utensils, laundered linens, and single-service and single-use articles shall be stored:
(1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and
(3) At least 15 centimeters (6 inches) above the deck.
Do not store clean utensils and equipment on the dirty side of the shield.
|
|
|
Item No.:
26
|
|
Site:
Other-BUTCHER SHOP
|
|
Violation:
THE PREVIOUSLY CLEANED MIXER FOOD SPLASH AREA WAS SOILED WITH DRIED FOOD DEBRIS.
|
|
Recommendation:
7.3.3.4.1
Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
|
|
|
Item No.:
15
|
|
Site:
Other-PROVISIONS DRY STORES
|
|
Violation:
TWO DENTED CANS WERE NOTED ON THE SHELVES IN THE DRY STORE AREA.
|
|
Recommendation:
7.3.2.2.5
Food packages shall be in good condition and protect the integrity of the contents so that the food is not exposed to adulteration or potential contaminants. Canned goods with dents on end or side seams may not be used.
|
|