Cruise Ship: Club Med 2 Cruise Line: Club Med Marine Inspection Date: 04/12/2004 Inspection Score: 94
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 20
Site: Other-LIDO-GRAND BLEU
Violation: A CONTAINER OF SOFT CHEESE WAS MEASURED AT A TEMPERATURE OF 52 °F IN THE GRAND BLEU REFRIGERATION UNIT # 26. THE PRODUCT HAD BEEN PLACED IN THE UNIT THE DAY BEFORE.
Recommendation: 7.4.5.1.1.1 Food-contact equipment shall be maintained in good repair and proper adjustment including: (1) Equipment shall be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 21
Site: Other-GRAND BLEU BUFFET
Violation: THE LATCH WAS BROKEN ON REFRIGERATION UNIT # 27.
Recommendation: 6.3.2.2.3 Nonfood-contact equipment shall be maintained in good repair and proper adjustment including: (2) Equipment components such as doors, seals, hinges, fasteners, and kick plates shall be kept intact, tight, and adjusted in accordance with manufacturer's specifications.
Item No.: 26
Site: Other-GRAND BLEU
Violation: THE PREVIOUSLY CLEANED FRYER COILS WERE SOILED WITH ENCRUSTED GREASE DEBRIS.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 21
Site: Other-GRAND BLEU
Violation: PEELING SEALANT WAS NOTED IN THE VENTILATION SYSTEMS AND ON THE EXTERIOR OF SOME OF THE EQUIPMENT.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 22
Site: Other-GRAND BLEU DISHWASH
Violation: THE DATA PLATE WAS NO LONGER READABLE ON THE DISHWASH MACHINE.
Recommendation: 7.5.2.2.3 A warewashing machine shall be provided with an easily accessible and readable data plate affixed to the machine by the manufacturer that indicates the machine's design and operating specifications including the: (1) Temperatures required for washing, rinsing, and sanitizing; (2) Pressure required for the fresh water sanitizing rinse; and (3) Conveyor speed for conveyor machines or cycle time for stationary rack machines.
Item No.: 41
Site: Other-VENTILATION
Violation: THE DRAIN PANS ON THE VENTILATION UNITS WERE SEVERELY CORRODED. THIS IS A REPEAT VIOLATION FROM THE 12/01/2003 INSPECTION. THE VENTILATION SYSTEM CONDENSATE PANS ARE SCHEDULED FOR REPAIR DURING DRY DOCK IN OCTOBER.
Recommendation: 9.2.1.2.1 Air handling units shall be kept clean.
Item No.: 19
Site: Other-PROVISIONS
Violation: CARCASSES OF LAMB WRAPPED IN A PLASTIC BAG WERE NOTED ON THE DECK IN THE MEAT FREEZER. THE CONDENSER DRAIN HAD BROKEN AND FROZEN ICE WAS NOTED ON SEVERAL BOXES OF FROZEN LAMB STORED BENEATH THE CONDENSER DRAIN. THESE PRODUCTS WERE REMOVED FROM THE BAGS/BOXES AND PLACED IN CONTAINERS.
Recommendation: 7.3.3.3.2 Packaged food may not be stored in direct contact with ice or water if the food is subject to the entry of water because of the nature of its packaging, wrapping, or container, or its positioning in the ice or water. 7.3.3.5.1 Food shall be protected from contamination by storing the food: (1) In a clean, dry location; (2) Where it is not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 19
Site: Other-PROVISIONS-BUTCHER SHOP
Violation: THE INSECT DEVICE WAS LOCATED OVER THE BUTCHER'S PREPARATION TABLE. THIS WAS A GLUE TYPE DEVICE.
Recommendation: 8.2.2.2.2 The insect devices shall not be located over food storage, preparation, and service areas. Dead insects and insect fragments shall be prevented from being impelled onto or falling on exposed food.
Item No.: 27
Site: Other-CREW MESS
Violation: THE TECHNICAL AREAS BELOW THE DRINK STATION AND BUFFET LINE WERE SEVERELY SOILED.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Other-VENICE BAR
Violation: THE TECHNICAL AREA AROUND THE FLOOR DRAIN WAS SOILED. THE UNSEALED PENETRATIONS THROUGH THE BULKHEAD MADE THIS AREA DIFFICULT TO CLEAN AND PROVIDED HARBORAGE FOR INSECTS.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 40
Site: Other-INTEGRATED PEST MANAGEMENT
Violation: DOCUMENTATION OF TRAINING FOR THE PEST CONTROL PERSONNEL WAS NOT INCLUDED IN THE INTEGRATED PEST MANAGEMENT PLAN. THIS IS A REPEAT VIOLATION FROM THE 12/01/2004 INSPECTION.
Recommendation: 8.1.2.1.3 The training of the pest-control personnel shall be documented in the Integrated Pest Management Plan.
Item No.: 33
Site: Other-CREW OFFICE
Violation: CONTAINERS OF DISHWASHING CHEMICALS AND HOSES WERE NOTED ON THE DECK, MAKING THE DECK DIFFICULT TO CLEAN.
Recommendation: 7.7.4.1.8 Surfaces subject to routine splashes, spillage or other soiling during normal use shall have easily cleanable features.
Item No.: 26
Site: Other-COLD BUFFET
Violation: THE FOOD SPLASH ZONE ON THE PREVIOUSLY CLEANED MIXER WAS SOILED.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 20
Site: Other-COLD BUFFET
Violation: PEELING SOFT SEALANT WAS NOTED ON THE BACK BLADE OF THE SLICER.
Recommendation: 7.4.2.1.1 Food contact surfaces of equipment and utensils shall be designed and constructed to be durable and to retain their characteristic qualities under normal use conditions.
Item No.: 20
Site: Other-MAIN GALLEY POTWASH
Violation: TWO CUTTING BOARDS HAD DEEP GOUGES MAKING THEM DIFFICULT TO CLEAN.
Recommendation: 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 26
Site: Other-MAIN GALLEY POTWASH
Violation: TWO PREVIOUSLY CLEANED CUTTING BOARDS WERE SOILED AND STORED ON THE CLEAN SHELF.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 20
Site: Other-FOOD SERVICE GENERAL
Violation: THE KOLD DRAFT ICE MACHINES HAD LARGE GAPS (1/4-1") BETWEEN THE BIN AND CUBER SECTIONS. CORROSION WAS NOTED INSIDE THE CUBER AND BIN AREA AND THE CUBER DRAIN EXITED THROUGH THE ICE BINS. THE FITTINGS ON THE PLASTIC DRAINS WERE NOT EASY TO CLEAN DUE TO ROUGH SEAMS.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition. 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches. 7.4.2.4.7 Liquid waste drain lines may not pass through an ice machine or ice storage bin.
Item No.: 26
Site: Other-FOOD SERVICE GENERAL
Violation: THE KOLD DRAFT ICE MACHINES WERE SOILED IN THE CUBER AREA AND AROUND THE GASKETS. MOLD WAS NOTED AROUND THE FITTINGS TO THE CUBER DRAIN.
Recommendation: 7.3.3.4.1 Food shall only contact surfaces of equipment and utensils that are cleaned and sanitized.
Item No.: 03
Site: Other-POTABLE WATER
Violation: THE RECORDS FOR THE BUNKERING AND PRODUCTION OF POTABLE WATER SHOWED THE HALOGENATION CONCENTRATION BELOW 2 PPM ON THE FOLLOWING DATES: 04/10/2004-PRODUCTION-5 HOURS 01/01/2004-PRODUCTION-15 HOURS 12/31/2003-PRODUCTION-11 HOURS 12/29/2004-PRODUCTION-6 HOURS 12/19/2003-BUNKERING-13 HOURS-PORT OF FRANCE THE VESSEL WAS NOT OPERATING IN U.S. WATERS AT THE TIME.
Recommendation: 5.2.1.1.1 Potable water shall be continuously halogenated to at least 2.0 mg/L (ppm) free residual halogen at the time of bunkering or production with an automatic halogenation device.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE INTERNATIONAL SHORE CONNECTION REDUCED PRESSURE ASSEMBLY BACKFLOW PREVENTOR HAD NOT BEEN TESTED.
Recommendation: 5.7.2.2.2 Backflow prevention devices requiring testing, for example reduced pressure backflow preventer and double check valves with test cocks, shall be inspected and tested with a test kit at least annually. Test results showing the pressure differences on both sides of the valves shall be maintained for each device.
Item No.: 28
Site: Other-COLD BUFFET
Violation: PREVIOUSLY CLEANED UTENSILS AND DISHES WERE STORED ON THE DIRTY SIDE OF THE THREE COMPARTMENT SINK.
Recommendation: 7.5.7.3.1 Cleaned equipment and utensils, laundered linens, and single-service and single-use articles shall be stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 33
Site: Other-FOOD SERVICE GENERAL
Violation: CRACKED AND BROKEN DECK TILES AND RECESSED GROUT WERE NOTED THROUGH OUT THE FOOD SERVICE AREAS. THIS IS SCHEDULED FOR REPAIR DURING DRY DOCK.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME-CLUB MED 2 - CAS - [INSPECTION DATE 04/12/2004] .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory