Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: National Geographic Orion Cruise Line: Lindblad Expeditions Inspection Date: 05/24/2004 Inspection Score: 92
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 33
Site: Other-PROVISIONS
Violation: TWO CONTAINERS OF ICE CREAM WERE NOTED ON THE DECK IN THE DAIRY FREEZER.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 16
Site: Other-PROVISIONS
Violation: THREE CONTAINERS OF YOGURT AND ONE CONTAINER OF SOUR CREAM WERE FOUND STORED IN THE HANDLING AREA WITH INTERNAL TEMPERATURES BETWEEN 52-55°F. THE AMBIENT THERMOMETER IN THIS AREA WAS READING APPROXIMATELY 12°C. THE CONTAINERS TESTED WERE TAKEN FROM RANDOM AREAS ON DIFFERENT PALLETS.
Recommendation: 7.3.5.3.1.1 Potentially hazardous food shall be maintained: (1) At 60°C (140°F) [roasts 54°C (130°F)] or above,; or (2) At 5°C (41°F) or less.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: ORION - CAS - 5/24/2004.
Recommendation:
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE POTABLE WATER PRODUCTION LOG LISTED THE WATCH TIMES INSTEAD OF THE ACTUAL TIME THE FREE HALOGEN RESIDUAL TEST WAS TAKEN. IT WAS DIFFICULT TO DETERMINE IF TESTS WERE BEING CONDUCTED EVERY FOUR HOURS.
Recommendation: 5.2.1.2.2 Free residual halogen monitoring shall be performed at least hourly during the bunkering of potable water and performed at least once every 4 hours during the onboard production of potable water.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE POTABLE WATER HOSE LOCKERS WERE NOT SELF-DRAINING.
Recommendation: 5.3.3.1.7 The potable water hose lockers shall be mounted at least 45 cm (18 inches) above the deck and shall be self-draining.
Item No.: 06
Site: Other-POTABLE WATER
Violation: THE HALOGEN ANALYZER-CHART RECORDER CHARTS FOR THE DISTRIBUTION SYSTEM HAD A RANGE OF 0-50 PPM. FROM 5/15-23/2004, THE HALOGEN ANALYZER-CHART RECORDER CHARTS FOR THE DISTRIBUTION SYSTEM WERE NOT INITIALED.
Recommendation: 5.5.2.1.1 Halogen analyzer-chart recorder charts shall have a range of 0.0 to 5.0 mg/L (ppm) and have a recording period of 24 hours. 5.5.2.2.1 Halogen analyzer-chart recorder charts shall be changed, initialed, and dated daily. Charts shall contain notations of any unusual water events in the potable water system.
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE VESSEL DID NOT HAVE A COMPREHENSIVE CROSS-CONNECTION CONTROL PROGRAM IN PLACE.
Recommendation: 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 10
Site: Other-WHIRLPOOL
Violation: A SIGN WAS NOT INSTALLED NEAR THE WHIRLPOOL LISTING STANDARD SAFETY PRECAUTIONS AND RISKS, WARNING AGAINST USE BY PARTICULARLY SUSCEPTIBLE PEOPLE, SUCH AS THOSE WHO ARE IMMUNOCOMPROMISED.
Recommendation: 6.4.1.1.3 A sign shall be installed near the whirlpool spas that lists standard safety precautions and risks, warning against use by particularly susceptible people, such as those who are immunocompromised.
Item No.: 40
Site: Other-INTEGRATED PEST MANAGEMENT
Violation: THE INTEGRATED PEST MANAGEMENT PLAN DID NOT STATE THAT SOME INSPECTIONS SHALL BE CONDUCTED AT NIGHT.
Recommendation: 8.1.1.1.2 The Integrated Pest Management Plan shall set a schedule for periodic monitoring inspections including some at night.
Item No.: 01
Site: Other-MEDICAL
Violation: A 24-HOUR PRIOR TO ARRIVAL GASTROINTESTINAL ILLNESS REPORT WAS NOT MADE BEFORE THE VESSEL ARRIVED IN ST. THOMAS FROM A FOREIGN PORT AND BEFORE THE VESSEL ARRIVED IN CHARLESTON FROM A FOREIGN PORT. THE DOCTOR STATED THAT HE WAS NOT AWARE OF THIS REQUIREMENT.
Recommendation: 4.2.1.1.1 The master, the medical staff, or other designated staff of a vessel destined for a U.S. port from a foreign port shall submit at least one standardized gastrointestinal illness report based on the number of reportable cases in the gastrointestinal illness log to the VSP no less than 24 hours, but not more than 30 hours before the vessel's expected arrival at the U.S. port.
Item No.: 30
Site: Other-MAIN GALLEY
Violation: A SIGN STATING "WASH HANDS OFTEN" WAS NOT POSTED AT THE HANDWASH SINK IN THE DISHWASH AREA.
Recommendation: 7.7.1.1.7 A sign stating "WASH HANDS OFTEN" in a language that the food employees understand shall be posted over handwashing sinks.
Item No.: 28
Site: Other-MAIN GALLEY
Violation: THE COFFEE CARAFES WERE NOT STORED IN A SELF-DRAINING POSITION THAT ALLOWED AIR DRYING.
Recommendation: 7.5.7.3.2 Clean equipment and utensils shall be stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 21
Site: Other-MAIN GALLEY
Violation: PLASTIC WRAP WAS STORED IN A CARDBOARD BOX ON A PREPARATION TABLE.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
Item No.: 27
Site: Other-MAIN GALLEY
Violation: THE CARDBOARD BOX THAT THE PLASTIC WRAP WAS STORED IN WAS SOILED.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 34
Site: Other-MAIN GALLEY
Violation: THE WATER PRESSURE AT THE DRINKING FOUNTAIN WAS NOT ADEQUATE SO THAT THE STREAM OF WATER DID NOT CLEAR THE SANITARY GUARD.
Recommendation: 7.7.3.3.1 A plumbing system in a food area shall be maintained in good repair. Ensure that the water pressure is increased so that the stream of water clears the sanitary guard.
Item No.: 30
Site: Other-MAIN GALLEY
Violation: A SIGN STATING "WASH HANDS OFTEN" WAS NOT POSTED AT THE HANDWASH SINK IN THE POTWASH AREA.
Recommendation: 7.7.1.1.7 A sign stating "WASH HANDS OFTEN" in a language that the food employees understand shall be posted over handwashing sinks.
Item No.: 26
Site: Other-MAIN GALLEY
Violation: NUMEROUS PIECES OF EQUIPMENT WERE SOILED AND STORED AS CLEAN IN THE POTWASH AREA.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 26
Site: Other-MAIN GALLEY
Violation: ONE KNIFE AND ONE CAN OPENER WERE SOILED AND STORED AS CLEAN IN THE KNIFE LOCKER IN THE AREA NEXT TO THE POTWASH.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 30
Site: Other-MAIN GALLEY
Violation: A SIGN STATING "WASH HANDS OFTEN" WAS NOT POSTED AT THE HANDWASH SINK IN THE MEAT AND FISH PREPARATION AREA.
Recommendation: 7.7.1.1.7 A sign stating "WASH HANDS OFTEN" in a language that the food employees understand shall be posted over handwashing sinks.
Item No.: 26
Site: Other-MAIN GALLEY
Violation: ONE KNIFE WAS SOILED AND STORED AS CLEAN IN THE KNIFE LOCKER IN THE MEAT AND FISH PREPARATION AREA.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 26
Site: Other-MAIN GALLEY
Violation: FOUR KNIVES WERE SOILED AND STORED AS CLEAN IN THE KNIFE LOCKER IN THE VEGETABLE PREPARATION AREA.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 29
Site: Other-LEDA LOUNGE BAR
Violation: A HANDWASH SINK WAS NOT LOCATED IN THE BAR AREA. THE HANDWASH SINK WAS LOCATED IN THE PANTRY WHICH REQUIRED PASSAGE THROUGH A CLOSED DOOR.
Recommendation: 7.7.1.1.1 Each food preparation area, bar, warewashing area, and garbage-processing area shall have at least one handwashing facility located in it. 7.7.1.1.2 The handwashing facility shall be located within 8 m (25 feet) of all parts of the area and should not be located in an adjacent area that requires passage through a closed door.
Item No.: 30
Site: Other-GALAXY LOUNGE PANTRY
Violation: A SIGN STATING "WASH HANDS OFTEN" WAS NOT POSTED AT THE HANDWASH SINK.
Recommendation: 7.7.1.1.7 A sign stating "WASH HANDS OFTEN" in a language that the food employees understand shall be posted over handwashing sinks.
Item No.: 29
Site: Other-GALAXY LOUNGE BAR
Violation: A HANDWASH SINK WAS NOT LOCATED IN THE BAR AREA. THE HANDWASH SINK WAS LOCATED IN THE PANTRY WHICH REQUIRED PASSAGE THROUGH A CLOSED DOOR.
Recommendation: 7.7.1.1.1 Each food preparation area, bar, warewashing area, and garbage-processing area shall have at least one handwashing facility located in it. 7.7.1.1.2 The handwashing facility shall be located within 8 m (25 feet) of all parts of the area and should not be located in an adjacent area that requires passage through a closed door.
Item No.: 33
Site: Other-CREW MESS
Violation: A CRACKED DECK TILE WAS NOTED IN FRONT OF THE WAREWASH MACHINE.
Recommendation: 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program