Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: National Geographic Sea Lion Cruise Line: Lindblad Expeditions Inspection Date: 05/25/2004 Inspection Score: 80
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 22
Site: Other-GALLEY
Violation: SEVERAL DISHWARE RACKS WERE STORED DIRECTLY ON THE DECK IN FRONT OF THE DISHWASH MACHINE. ADDITIONALLY, SEVERAL SOILED SHEET PANS AND A CUTTING BOARD WERE STORED DIRECTLY ON THE DECK AT THE DISHWASH MACHINE. A SALAD WASHER STORED DIRECTLY ON THE DECK FOR WASHING WAS MOVED FROM THE DECK TO A FOOD COUNTER WITHOUT FIRST CLEANING THE UNIT.
Recommendation: 7.5.3.2.1 Drainboards, utensil racks, or tables large enough to accommodate all soiled and cleaned items that may accumulate during hours of operation shall be provided for necessary utensil holding before cleaning and after sanitizing. Provide deck stands to prevent items being stored in contact with the deck and to prevent soilage from decks being transferred to food preparation counters and water inside the dishwash machine.
Item No.: 12
Site: Other-GALLEY
Violation: A FOOD WORKER WAS OBSERVED EATING LINK SAUSAGES WITH BARE HANDS FROM A PARTIALLY FULL BAIN PAN IN THE GALLEY. HE THEN DISCARDED THE REST OF THE SAUSAGES.
Recommendation: 7.2.4.1.1 An employee shall eat, drink, or use any form of tobacco only in designated areas where the contamination of exposed food; clean equipment, utensils, and linens; unwrapped single-service and single-use articles; or other items needing protection can not result.
Item No.: 12
Site: Other-GALLEY
Violation: A FILLED BOTTLE OF DRINKING WATER WAS OBSERVED STORED BESIDE CLEAN DISHWARE IN AN UPPER CABINET NEAR THE DISHWASH MACHINE. THE FOOD WORKER NEARBY STATED THAT THIS WAS HIS WATER BOTTLE AND WAS USED FOR DRINKING WHILE WORKING IN THE GALLEY.
Recommendation: 7.2.4.1.1 An employee shall eat, drink, or use any form of tobacco only in designated areas where the contamination of exposed food; clean equipment, utensils, and linens; unwrapped single-service and single-use articles; or other items needing protection can not result.
Item No.: 24
Site: Other-GALLEY - DISHWASH
Violation: DURING ACTIVE USE OF THE SINGLE RACK DISHWASH MACHINE THE HOT WATER FINAL SANITIZING RINSE WAS ONLY 154 °F AT THE DISH SURFACE. IT WAS DETERMINED THAT THE EQUIPMENT STACKED ON THE DECK IN FRONT OF THE MACHINE HAD CONTACTED THE LOWER BOOSTER HEATER SWITCH AND IT WAS OFF. THE HEATER WAS SWITCHED ON AND A DISH LEVEL TEMPERATURE OF 162 °F WAS REACHED. GALLEY STAFF WERE NOT EQUIPPED WITH IRREVERSIBLE THERMOMETERS TO MEASURE THE DISH LEVEL TEMPERATURE. A PACKAGE OF TEMPERATURE MEASURING TAPE STICKERS WAS PROVIDED TO THE STAFF DURING THE INSPECTION.
Recommendation: 7.5.6.1.2 In a mechanical operation, the temperature of the fresh hot water sanitizing rinse as it enters the manifold may not be more than 90°C (194°F), or less than: (1) For a stationary rack, single temperature machine, 74°C (165°F); or (2) For all other machines, 82°C (180°F). (3) A utensil surface temperature of 71°C (160°F) as measured by an irreversible registering temperature indicator shall be achieved. (4) The maximum temperature of 90°C (194°F), does not apply to the high pressure and temperature systems with wand-type, hand-held, spraying devices used for the in-place cleaning and sanitizing of equipment such as meat saws. Provide proper thermometers for measuring plate level temperatures. Install a cover over the booster heater on/off switch to prevent it from accidentally being moved by the items staged in front of it.
Item No.: 33
Site: Other-GALLEY - DISHWASH
Violation: A BIN FULL OF BROKEN GLASSWARE WAS STORED DIRECTLY ON THE DECK BENEATH THE DISHWASH MACHINE. THE DECK BENEATH THE MACHINE AND ADJACENT BOOSTER HEATER WAS FILTHY WITH A PUTRESCIBLE FOOD DEBRIS, DIRT, AND STANDING WATER MIXTURE.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning. Keep the area beneath the machine open for cleaning. Provide a small garbage bin adjacent to the machine if necessary for discarding broken glassware. Clean the deck beneath the machine daily.
Item No.: 18
Site: Other-GALLEY
Violation: A CONTAINER OF RAW SHELL EGGS WAS STORED ON A SHELF WITH BAGS OF SHREDDED CHEESES AND DIRECTLY ABOVE PASTEURIZED EGG CARTONS AND BLOCK CHEESES IN THE LARGE REACH-IN REFRIGERATOR.
Recommendation: 7.3.3.2.1.1 Food shall be protected from cross-contamination by: (1) Physically separating raw animal foods during storage, preparation, holding, and display from raw ready-to-eat food including other raw animal food such as fish for sushi or molluscan shellfish, or other raw ready-to-eat food such as vegetables, and cooked ready-to-eat food; so products do not physically touch, and so as to prevent dripping of one product into another. The raw eggs require a cooking step and must be stored separate from or below cheeses, pasteurized egg products, and other ready-to-eat foods.
Item No.: 16
Site: Other-GALLEY
Violation: A PACKAGE OF BLUE CHEESE DATED 15 MAY WAS FOUND ON THE STORAGE SHELF IN THE LARGE REACH-IN REFRIGERATOR. THE STAFF STATED THAT THIS WAS THE DATE THE PACKAGE WAS OPENED. THERE WAS NO PLAN FOR DISCARD OF THIS PRODUCT.
Recommendation: 7.3.5.3.2 Refrigerated, ready-to-eat, potentially hazardous food: (2) A container of refrigerated, ready-to-eat potentially hazardous food prepared and packaged by a food processing plant shall be clearly marked, at the time the original container is opened, to indicate the date by which the food shall be consumed which is, including the day the original container is opened, 7 calendar days or fewer after the original container is opened. 7.3.5.3.3 Refrigerated, ready-to-eat, potentially hazardous food shall be discarded if not consumed within 7 calendar days from the date of preparation or opening.
Item No.: 28
Site: Other-GALLEY - GENERAL
Violation: NEARLY ALL OF THE CLEANED DISHWARE, PITCHERS, GLASSWARE, AND OTHER SUCH ITEMS WERE NOT INVERTED OR COVERED IN STORAGE. SOME PREVIOUSLY CLEANED SMALL PANS IN AN UNDER COUNTER STORAGE SHELF HAD STANDING WATER INSIDE THEM.
Recommendation: 7.5.7.3.2 Clean equipment and utensils shall be stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 33
Site: Other-GALLEY - GENERAL
Violation: BULKHEADS HAD ATTACHED LIGHTS, PIPING FROM FIRE PROTECTION, AND GAPS BEHIND EXHAUST HOOD WHICH MADE CLEANING DIFFICULT. DECKHEADS HAD PENETRATIONS WHERE PIPING AND CONDUIT PASSED, AND GAPS OVER THE LARGE REFRIGERATOR WHICH WERE DIFFICULT TO CLEAN.
Recommendation: 7.7.4.1.6 Light fixtures, vent covers, and similar equipment attached to the bulkheads or deckheads shall be easily cleanable. 7.7.4.1.7 Exposed utility service lines and pipes, including lines for fire detection and protection systems, shall be installed so they do not obstruct or prevent cleaning.
Item No.: 21
Site: Other-GALLEY
Violation: AN OPEN GAP WAS PRESENT IN THE UPPER REAR PANEL INSIDE THE LOWER STORAGE CABINET ON THE LEFT SIDE OF THE DISHWASH MACHINE.
Recommendation: Profile the gap by welding a metal profile piece to the section to form a tight seal.
Item No.: 21
Site: Other-GALLEY
Violation: A GAP WAS PRESENT ALONG THE OUTSIDE PERIMETER OF THE GRILL TOP, MAKING CLEANING AROUND IT DIFFICULT. THERE WAS A DIFFICULT TO CLEAN GAP BETWEEN THE FRONT OF THE RANGE OVEN AND GRILL OVEN, WHERE THOSE EQUIPMENT PIECES JOIN. THERE WAS ALSO A DIFFICULT TO CLEAN GAP WHERE THE GREASE PANS INSERT AND AT THE UNDERSIDE OF THE FRONT EDGE OF THE GRILL AND RANGE TOP.
Recommendation: 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Other-GALLEY
Violation: THE GAPS IN AND AROUND THE GRILL TOP AND BETWEEN THE RANGE OVEN AND GRILL OVEN WERE HEAVILY SOILED WITH ACCUMULATED GREASE AND FOOD DEBRIS. CONGEALED RESIDUE WAS DRIPPING FROM THE LOWER GAP OF THE TWO OVENS TO THE DECK BELOW.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 26
Site: Other-GALLEY
Violation: THE INTERIOR OF THE GRILL OVEN WAS SOILED WITH AN ACCUMULATED LAYER OF ENCRUSTED FOOD/GREASE RESIDUE WHICH HAD BURNED-ON TO THE INTERIOR PANELS OF THE OVEN.
Recommendation: 7.5.5.1.2 The food-contact surfaces of cooking equipment and pans shall be kept free of encrusted grease deposits and other soil accumulations. Increase the cleaning frequency of this oven to prevent the heavy build-up of burned on food and grease debris.
Item No.: 39
Site: Other-GALLEY
Violation: THE PORTHOLE WINDOW AT THE AFT/STARBOARD GALLEY WAS OPEN DURING THE INSPECTION. THE WINDOW WAS NOT FITTED WITH A SCREEN TO PREVENT INSECT ENTRY.
Recommendation: Install a screen for this window.
Item No.: 26
Site: Other-GALLEY
Violation: THE 3 FAN GUARDS ON THE UPPER INTERIOR OF THE LARGE REACH-IN REFRIGERATOR WERE HEAVILY SOILED WITH A MOLDY DIRT RESIDUE.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch. Remove the fan guards and clean them more frequently.
Item No.: 38
Site: Other-GALLEY
Violation: AN EMPLOYEE BASEBALL HAT WAS STORED ON A STORAGE SHELF INSIDE THE GALLEY ENTRANCE. TWO STACKS OF PREVIOUSLY CLEANED PLATE COVERS WERE STORED DIRECTLY BESIDE THE HAT ON THE SAME SHELF.
Recommendation: 7.7.7.1.1 Only articles necessary for the food service operation shall be stored in food preparation, food storage, and warewashing areas.
Item No.: 28
Site: Other-GALLEY
Violation: TWO STACKS OF PREVIOUSLY CLEANED PLATE COVERS WERE STORED ON THE UPPER SHELF INSIDE THE GALLEY. THE SHELF WAS VISIBLY SOILED WITH DIRT AND DUST DEBRIS.
Recommendation: 7.5.7.3.1 Cleaned equipment and utensils, laundered linens, and single-service and single-use articles shall be stored: (1) In a clean, dry location; (2) Where they are not exposed to splash, dust, or other contamination; and (3) At least 15 centimeters (6 inches) above the deck.
Item No.: 19
Site: Other-GALLEY - GENERAL
Violation: SEVERAL CLEAR PLASTIC SPRAY BOTTLES WERE IN USE AND FOUND INSIDE THE GALLEY. EACH BOTTLE HAD AN AFFIXED, PERMANENT, AND COLORED LABEL FROM THE MANUFACTURER READING 'SYSCO CHEMICAL'. THOSE SPRAY BOTTLES CONTAINED CLEANERS, DEGREASERS, AND BLEACH WATER SOLUTIONS. THE SAME BOTTLE TYPE CONTAINED WATER AND OLIVE OIL AT THE PREPARATION COUNTER. ONE BOTTLE WAS LABELED WATER, BUT THE OLIVE OIL SPRAY BOTTLE WAS UNLABELED.
Recommendation: 7.3.3.2.3 Working containers holding food or food ingredients that are removed from their original packages for use on the vessel, such as cooking oils, flour, herbs, potato flakes, salt, spices, and sugar shall be identified with the common name of the food. Recommend that an entirely different food product spray bottle (size, shape, label) be provided and used to ensure that errors in refilling or use do not occur from a chemical to a food product.
Item No.: 25
Site: Other-GALLEY, DINING ROOM, AND LOUNGE BAR
Violation: A WET WIPING CLOTH WAS SET ON A COUNTER BESIDE THE HANDWASH STATION IN THE GALLEY. A WET WIPING CLOTH WAS DRAPED OVER THE HANDWASH SINK WATER TAP IN THE LOUNGE BAR. A WIPING CLOTH WAS STORED IN A WATER BOWL MARKED BLEACH IN THE DINING ROOM, BUT THERE WAS NO CHLORINE RESIDUAL IN THE WATER IN THAT BOWL.
Recommendation: 7.3.3.4.4.2 Wiping cloths shall be restricted to the following: (2) Cloths used for wiping food spills shall be dry and used for wiping food spills from tableware and single-service articles or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment.
Item No.: 33
Site: Other-WALK-IN FREEZER
Violation: ATTACHED PIPING AND WIRING ON BULKHEADS MADE THEM DIFFICULT TO CLEAN.
Recommendation: 7.7.4.1.7 Exposed utility service lines and pipes, including lines for fire detection and protection systems, shall be installed so they do not obstruct or prevent cleaning.
Item No.: 21
Site: Other-DRY STORES
Violation: THE SPACE BENEATH SOME OF THE SHELVES WAS ONLY 2-3 INCHES, MAKING ACCESS FOR CLEANING DIFFICULT. PLASTIC TYPE BINS USED AS DECK STORAGE STANDS, DID NOT ALLOW FOR CLEANING BENEATH, IN DRY STORES AND THE WALK-IN FREEZER UNIT.
Recommendation: 7.4.4.2.1 Deck-mounted equipment that is not easily movable shall be sealed to the deck or elevated on legs that provide at least a 15-centimeter (6-inch) clearance between the deck and the equipment. Additionally, foods shall be stored at least 6 inches above the deck.
Item No.: 29
Site: Other-LOUNGE BAR
Violation: A DUMP PAN INSERT WAS SET INSIDE THE HANDWASH SINK. STAFF STATED THAT THIS SINK WAS USED FOR DRINK DUMPING AT TIMES DURING OPERATION.
Recommendation: 7.7.1.3.1 Handwashing facilities shall be used for no other purpose and shall be accessible at all times.
Item No.: 13
Site: Other-FOOD SAFETY KNOWLEDGE
Violation: BASED ON THE NUMBER AND TYPE OF FOOD SAFETY ITEMS NOTED, THE GALLEY STAFF DEMONSTRATED A LACK OF UNDERSTANDING ON HOW FOOD SAFETY APPLIES IN THEIR DUTIES, SPECIFICALLY IN HANDLING OF CLEAN AND SOILED DISHWARE, PERSONAL HYGIENE AND SANITARY PRACTICES, FOOD PROTECTION, AND TEMPERATURE MONITORING IN DISHWASHING.
Recommendation: 7.2.1.2.1.12 The person in charge of the food operations on the vessel shall ensure that: (12) Employees are properly trained in food safety as it relates to their assigned duties.
Item No.: 06
Site: Other-POTABLE WATER - DISTRIBUTION
Violation: THE DISTRIBUTION CHLORINATION SYSTEM HAS DUPLICATION IN AN OPERATING 'A' OR 'B' PUMP, BUT THE TWO PUMPS ARE NOT CONNECTED ELECTRONICALLY SO THAT THERE WILL BE AN AUTOMATIC SWITCHOVER IN THE EVENT THE PRIMARY PUMP IN-USE FAILS.
Recommendation: 5.4.1.2.3 At least one backup halogen pump shall be available with automatic switchover to maintain the free residual halogen in the event that the primary pump fails.
Item No.: 06
Site: Other-POTABLE WATER - MICROBIOLOGICAL TESTS
Violation: THERE WERE NO RECENT MICROBIOLOGICAL TESTS FOR E. COLI BACTERIA FOR THIS SEASON WHEN THE SHIP HAS BUNKERED POTABLE WATER FROM BRITISH COLUMBIA OR SEATTLE. THE TESTS FOR ALASKA WERE ONBOARD AND CURRENT.
Recommendation: 5.1.1.2.1 Where available, the vessel shall have a copy of the most recent microbiologic report from each port before bunkering potable water to verify that the water meets potable standards. The ship may use the onboard potable water microbial test when port water quality reports are not available.
Item No.: 01
Site: Other-MEDICAL - REPORTING
Violation: THE SHIP HAS NOT MADE THE ROUTINE, 24-HOUR, PRIOR TO ARRIVAL GASTROINTESTINAL ILLNESS REPORT TO CDC FOR THE CURRENT CRUISE, OR THE PREVIOUS TWO CRUISES WHEN SAILING FROM A FOREIGN TO U.S. PORT.
Recommendation: 4.2.1.1.1 The master, the medical staff, or other designated staff of a vessel destined for a U.S. port from a foreign port shall submit at least one standardized gastrointestinal illness report based on the number of reportable cases in the gastrointestinal illness log to the VSP no less than 24 hours, but not more than 30 hours before the vessel's expected arrival at the U.S. port.
Item No.: 02
Site: Other-MEDICAL - LOGS
Violation: THERE WAS NO GASTROINTESTINAL ILLNESS SURVEILLANCE LOG MAINTAINED FOR THE 3-WEEK SAILING FROM BELIZE TO COLUMBIA RIVER IN APRIL/MAY OF 2004.
Recommendation: 4.1.2.1.1 A standardized gastrointestinal illness surveillance log for each cruise shall be maintained daily by the master of the vessel, the medical staff, or other designated staff.
Item No.: *
Site: Other-COMMENT - CORRECTIVE ACTION
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SHIP NAME - CAS - [INSERT INSPECTION DATE] .
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory