Item No.:
24
|
|
Site:
Other-LA VERANDA
|
|
Violation:
STAFF WERE OBSERVED IMMERSING CLEAN POTS IN THE SANITIZING RINSE SINK FOR ONLY 3-5 SECONDS .
|
|
Recommendation:
7.5.6.2.2
A chemical sanitizer shall be used in accordance with the EPA-approved manufacturer's label use instructions at a minimum temperature of 24°C (75°F) with an exposure time of 7 seconds for a chlorine solution and 30 seconds for other chemical sanitizers.
|
|
|
Item No.:
21
|
|
Site:
Other-OBSERVATION LOUNGE PANTRY
|
|
Violation:
THE PLASTIC LEGS OF A HOT PLATE WERE ATTACHED WITH "DUCT TAPE" MAKING THE UNIT DIFFICULT TO CLEAN.
|
|
Recommendation:
7.4.1.1.9
Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
21
|
|
Site:
Other-MARINER LOUNGE PANTRY
|
|
Violation:
THE TOP FOR THE ROLLING TABLE USED FOR COOKING DEMONSTRATIONS WAS MADE OF PLYWOOD MAKING IT DIFFICULT TO CLEAN.
|
|
Recommendation:
7.4.1.1.9
Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
41
|
|
Site:
Other-AIR HANDLING SYSTEMS
|
|
Violation:
AIR HANDLING CONDENSATE DRAIN PANS AND COLLECTION UNITS, WITH THE EXCEPTION OF THE CASINO AREA UNIT, ARE NOT ACCESSIBLE FOR INSPECTION.
|
|
Recommendation:
9.2.1.1.1
Air handling unit condensate drain pans and collection systems shall be accessible for inspection, maintenance, and cleaning.
|
|
|
Item No.:
41
|
|
Site:
Other-AIR HANDLING SYSTEM
|
|
Violation:
THE AIR CONDITIONING CONDENSATION COLLECTION PAN FOR THE CASINO AREA HAD MORE THAN 2 INCHES OF STANDING WATER
|
|
Recommendation:
9.2.1.1.2
Air condition condensation collection pans shall be self-draining.
|
|
|
Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: SEVEN SEAS MARINER - CAS - JULY 28, 2004.
|
|
Recommendation:
|
|
|
Item No.:
16
|
|
Site:
Other-MAIN GALLEY / COLD PANTRY
|
|
Violation:
POTENTIALLY HAZARDOUS FOOD (CUT MELONS) WERE FOUND STORED IN AN UNDERCOUNTER REFRIGERATOR THAT WAS LABELED "TIME CONTROL" AND THE DATE LABEL ON THE PAN SHOWED A DISCARD DATE 7 DAYS AFTER PREPARATION NOT 4 HOURS AFTER PREPARATION.
|
|
Recommendation:
Ensure all potentially hazardous food where time as a public health control is used are labeled with a discard time 4 hours after preparation.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY / POT WASH AREA
|
|
Violation:
THE POT WASHING MACHINE WAS LABELED OUT OF ORDER. IT WAS STATED THAT IT HAD BEEN OUT OF ORDER FOR APPROXIMATELY 10 DAYS.
|
|
Recommendation:
Repair the potwash machine.
|
|
|
Item No.:
22
|
|
Site:
Other-CREW GALLEY
|
|
Violation:
THE GLASSWASHING MACHINE WAS LABELED OUT OF ORDER. IT WAS STATED THAT THE MACHINE HAD BEEN OUT OF ORDER FOR APPROXIMATELY 1 MONTH.
|
|
Recommendation:
Repair the glasswashing machine.
|
|
|
Item No.:
19
|
|
Site:
Other-AFT MOORING DECK
|
|
Violation:
CONTAINERS OF FOOD ITEMS WERE FOUND SETTING ON THE MOORING DECK. IT APPEARED THAT CREW MEMBERS HAD MADE AN ATTEMPT TO QUICKLY REMOVE THESE ITEMS FROM A SERVICE OR PREPARATION AREA WHEN THE INSPECTORS BOARDED THE VESSEL.
|
|
Recommendation:
Ensure that the crew is trained and confident in their knowledge of public health practices to prevent panic responses that create potential public health problems.
|
|
|
Item No.:
28
|
|
Site:
Other-AFT MOORING DECK
|
|
Violation:
CLEAN AND SOILED EQUIPMENT AND UTENSILS WERE FOUND SETTING ON THE MOORING DECK. IT APPEARED THAT CREW MEMBERS HAD MADE AN ATTEMPT TO QUICKLY REMOVE THESE ITEMS FROM A SERVICE OR PREPARATION AREA WHEN THE INSPECTORS BOARDED THE VESSEL.
|
|
Recommendation:
Ensure that the crew is trained and confident in their knowledge of public health practices to prevent panic responses that create potential public health problems.
|
|