|
|
|
Item No.:
21
|
|
Site:
Other-TERRACE CAFÉ BUFFET LINE
|
|
Violation:
THE ELECTRICAL CORD FOR THE JUICE MACHINE WAS DRAPING THE COUNTER, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
7.4.2.2.6
Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
33
|
|
Site:
Other-TERRACE CAFÉ BUFFET LINE
|
|
Violation:
THE ELECTRICAL CORD FOR THE JUICE MACHINE WAS DRAPING THE DECK, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
7.7.4.1.1
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
|
|
|
Item No.:
21
|
|
Site:
Other-TERRACE CAFÉ BUFFET LINE
|
|
Violation:
THE FINISH ON THE INDUCTION TROLLEY WAS PEELING AND CHIPPED IN SOME AREAS, EXPOSING WOOD THAT WAS DIFFICULT TO CLEAN.
|
|
Recommendation:
7.4.1.1.9
Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
7.4.2.2.6
Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
20
|
|
Site:
Other-SPECIALTY GALLEY
|
|
Violation:
TWO HOLES WERE NOTED ON THE SPLASH ZONE OF THE PASTA COOKER, MAKING THIS AREA DIFFICULT TO CLEAN.
|
|
Recommendation:
7.4.1.1.2
Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be:
(1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
21
|
|
Site:
Other-SPECIALTY GALLEY
|
|
Violation:
A LARGE GAP WAS NOTED AROUND THE GREASE CHUTE AREA ON THE GRILLS, MAKING THIS AREA DIFFICULT TO CLEAN.
|
|
Recommendation:
7.4.1.1.9
Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
7.4.2.2.6
Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
|
|
|
Item No.:
27
|
|
Site:
Other-SPECIALTY GALLEY
|
|
Violation:
THE GAP AROUND THE GREASE CHUTE AREA ON THE GRILL WAS HEAVILY SOILED WITH GREASE. THE GREASE TRAP AREA WAS ALSO SOILED WITH GREASE AND FOOD RESIDUE.
|
|
Recommendation:
7.5.5.1.3
Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
|
|
|
Item No.:
20
|
|
Site:
Other-SPECIALTY GALLEY
|
|
Violation:
HOLES WERE NOTED AROUND THE TEMPERATURE PROBES WHERE THE PROBE COVERS WERE MISSING, MAKING THIS AREA DIFFICULT TO CLEAN.
|
|
Recommendation:
7.4.1.1.2
Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be:
(1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
10
|
|
Site:
Other-POOLS & WHIRLPOOLS
|
|
Violation:
A CORE SAMPLE WAS NOT USED FOR THE MONTHLY SEDIMENTATION TESTS.
THE SHEPHERD'S HOOK AT THE SWIMMING POOL WAS NOT PLACED IN A PROMINENT LOCATION. THIS WAS CORRECTED DURING THE INSPECTION.
|
|
Recommendation:
6.3.1.1.5
The granular filters shall be opened at least monthly and examined for cracks, mounds, or holes in the filter media. A core sample of the filter media shall be inspected for excessive organic material accumulation using a recommended sedimentation method.
6.4.1.2.1
Easy access shepherd's hook and approved floatation device shall be provided at a prominent location near each public swimming pool.
|
|
|
Item No.:
08
|
|
Site:
Other-POTABLE WATER
|
|
Violation:
THE BACKFLOW PREVENTION DEVICES ON THE SHOWER HOSES IN THE CABINS WERE NOT LISTED ON THE CROSS CONNECTION CONTROL PROGRAM.
|
|
Recommendation:
Include these devices on the list of backflow prevention devices.
|
|
|
Item No.:
41
|
|
Site:
Other-VENTILATION
|
|
Violation:
THE CONDENSATE COLLECTION PAN IN UNIT ACR 4.04 WAS NOT ACCESSIBLE FOR INSPECTION, MAINTENANCE, AND CLEANING. IT WAS STATED BY THE ENGINEER THAT SOME OF THE UNITS ARE DESIGNED THIS WAY AND SOME HAVE CONDENSATE COLLECTION PANS THAT ARE ACCESSIBLE FOR INSPECTION, MAINTENANCE, AND CLEANING.
|
|
Recommendation:
Install an inspection hatch on the units that have pipes blocking access to the condensate collection area.
9.2.1.1.1
Air handling unit condensate drain pans and collection systems shall be accessible for inspection, maintenance, and cleaning.
|
|
|
Item No.:
30
|
|
Site:
Other-REGATTA BAR
|
|
Violation:
A SIGN STATING "WASH HANDS OFTEN" WAS NOT POSTED AT THE HANDWASH SINK.
|
|
Recommendation:
7.7.1.1.7
A sign stating "WASH HANDS OFTEN" in a language that the food employees understand shall be posted over handwashing sinks.
|
|
|
Item No.:
38
|
|
Site:
Other-PROVISIONS-VEGETABLE PREPARATION
|
|
Violation:
A MOP BUCKET WAS STORED IN THIS ROOM AFTER USE.
|
|
Recommendation:
7.7.7.1.1
Only articles necessary for the food service operation shall be stored in food preparation, food storage, and warewashing areas.
7.7.7.1.2
Maintenance tools such as mops, brooms, and similar items shall be stored in a designated locker so they do not contaminate food; food-contact surfaces of utensils; and equipment; linens, and single-service and single-use articles.
|
|
|
Item No.:
15
|
|
Site:
Other-PROVISIONS-GENERAL
|
|
Violation:
MUSSELS AND CLAMS WERE RECEIVED ON 11/11/2004. THE INVOICE NOTED APPROXIMATELY 50 KG BUT THE TAGS WERE FOR 7 KG.
|
|
Recommendation:
7.3.2.3.2
Shellstock shellfish tags shall:
(1) Remain attached to the container in which the shellstock are received until the container is empty. (2) Be maintained by retaining shellstock tags or labels for 90 calendar days from the date the container is emptied by using an approved record keeping system that keeps the tags or labels in chronologic order correlated to the date when the shellstock are served.
|
|
|
Item No.:
25
|
|
Site:
Other-PROVISIONS-BUTCHER/FISH ROOM
|
|
Violation:
THE WET WIPING CLOTH WAS NOT FULLY SUBMERGED IN THE SANITIZE BUCKET.
|
|
Recommendation:
7.3.3.4.4.2
Wiping cloths shall be restricted to the following:
(2) Cloths used for wiping food spills shall be dry and used for wiping food spills from tableware and single-service articles or wet and cleaned, stored in a chemical sanitizer, and used for wiping spills from food-contact and nonfood-contact surfaces of equipment.
|
|
|
Item No.:
34
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
THE HANDWASH SINK NEAR THE VEGETABLE PREPARATION AREA WAS OUT OF ORDER.
|
|
Recommendation:
Repair this handwash sink.
|
|
|
Item No.:
36
|
|
Site:
Other-MAIN GALLEY-BAKERY/PASTRY
|
|
Violation:
THE LIGHT SHIELDS IN THE TOP AND BOTTOM COMPARTMENTS OF THE STACK OVEN WERE BROKEN.
|
|
Recommendation:
7.7.5.2.1
Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens; or unwrapped single-service, and single-use articles.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY-BAKERY/PASTRY
|
|
Violation:
THE FLEXIBLE MUFFIN MOLDS WERE SOILED AND STORED AS CLEAN.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY-BAKERY/PASTRY
|
|
Violation:
THE FLEXIBLE MUFFIN MOLDS WERE STACKED WHILE WET, IMPEDING AIR DRYING.
|
|
Recommendation:
7.5.7.3.2
Clean equipment and utensils shall be stored:
(1) In a self-draining position that allows air drying; and (2) Covered or inverted.
7.5.7.1.1
After cleaning and sanitizing, equipment and utensils shall be air-dried or adequately drained before contact with food.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY-POTWASH
|
|
Violation:
A CONE STRAINER WAS SOILED AND STORED AS CLEAN.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY-POTWASH
|
|
Violation:
THE CUTTING BOARDS WERE STORED AGAINST EACH OTHER, IMPEDING AIR DRYING.
|
|
Recommendation:
7.5.7.1.1
After cleaning and sanitizing, equipment and utensils shall be air-dried or adequately drained before contact with food.
|
|
|
Item No.:
20
|
|
Site:
Other-MAIN GALLEY-POTWASH
|
|
Violation:
A FEW MIXING BOWLS HAD DEPRESSIONS IN THEM, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
7.4.1.1.2
Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be:
(1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY-POTWASH
|
|
Violation:
THE DEPRESSIONS IN THE MIXING BOWLS WERE NOTED TO CONTAIN FOOD SOIL.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
20
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
FASTENERS WERE MISSING ON THE HOT CABINET SHELF BRACKETS, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
7.4.1.1.2
Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be:
(1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
38
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
THE CLEANING LOCKER UNDER THE STAIRS WAS NOT LABELED.
|
|
Recommendation:
Ensure that this cleaning locker is labeled as such.
7.7.7.1.2
Maintenance tools such as mops, brooms, and similar items shall be stored in a designated locker so they do not contaminate food; food-contact surfaces of utensils; and equipment; linens, and single-service and single-use articles.
|
|
|
Item No.:
29
|
|
Site:
Other-DECK 5 ROOM SERVICE
|
|
Violation:
THE HANDWASH SINK AT THE CLEAN END OF THE WAREWASH UNIT WAS OUT OF ORDER. THE CLOSEST SINK TO THIS AREA WAS MORE THAN 25 FEET AWAY.
|
|
Recommendation:
7.7.1.1.2
The handwashing facility shall be located within 8 m (25 feet) of all parts of the area and should not be located in an adjacent area that requires passage through a closed door.
|
|
|
Item No.:
30
|
|
Site:
Other-GRAND BAR
|
|
Violation:
A "WASH HANDS OFTEN" SIGN WAS NOT POSTED OVER THE HANDWASH SINK.
|
|
Recommendation:
7.7.1.1.7
A sign stating "WASH HANDS OFTEN" in a language that the food employees understand shall be posted over handwashing sinks.
|
|
|
Item No.:
39
|
|
Site:
Other-CREW MESS
|
|
Violation:
SMALL FLIES WERE NOTED AT THE SOILED DROP-OFF.
|
|
Recommendation:
8.2.1.1.1
The presence of insects, rodents, and other pests shall be effectively controlled to minimize their presence in the food storage, preparation, and service areas and warewashing and utensil storage areas aboard a vessel.
|
|
|
Item No.:
26
|
|
Site:
Other-CREW GALLEY
|
|
Violation:
THE LEFT KETTLE DRAIN LINE WAS ENCRUSTED WITH FOOD RESIDUE.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
29
|
|
Site:
Other-CREW GALLEY
|
|
Violation:
THE 3-BUCKET SYSTEM WAS PARTIALLY BLOCKING ACCESS TO THE HANDWASH SINK.
|
|
Recommendation:
7.7.1.3.1
Handwashing facilities shall be used for no other purpose and shall be accessible at all times.
|
|
|
Item No.:
08
|
|
Site:
Other-MEDICAL
|
|
Violation:
THE BACKFLOW PREVENTION DEVICE AT THE BATHTUB WAS BELOW THE SPILL LINE OF THE TUB.
|
|
Recommendation:
Install the backflow prevention device so that it cannot be submerged in water.
|
|
|
Item No.:
20
|
|
Site:
Other-MAIN GALLEY-GARDE MANGER
|
|
Violation:
A SEAM WAS NOTED ALONG THE BACKPLATE OF THE SLICER, MAKING CLEANING DIFFICULT.
|
|
Recommendation:
7.4.1.1.2
Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be:
(1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
7.4.2.2.1
Multiuse food-contact surfaces shall be:
(1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY-GARDE MANGER
|
|
Violation:
THE SEAM ALONG THE BACKPLATE OF THE SLICER WAS SLIGHTLY SOILED WITH FOOD RESIDUE.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: REGATTA - CAS - 11/27/2004.
|
|
Recommendation:
|
|
|
Item No.:
17
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
THERE WAS NO INDICATION THAT THE COLD SMOKED SALMON WAS FROZEN TO THE TIME AND TEMPERATURE REQUIRED FOR PARASITE DESTRUCTION. THE DOCUMENTATION OF THE FREEZING WAS NOT AVAILABLE ON THE VESSEL. THE DOCUMENTATION WAS SENT VIA E-MAIL AFTER THE INSPECTION WAS COMPLETED.
|
|
Recommendation:
7.3.4.2.2
If raw, raw-marinated, partially cooked, or marinated-partially cooked fish are served in ready-to-eat form:
(1) The person in charge shall record the freezing temperature and time to which the fish are subjected and shall retain the records on the vessel for 90 calendar days beyond the time of service or sale of the fish; or (2) If the fish are frozen by a supplier, a written agreement or statement from the supplier stipulating that the fish supplied are frozen to a safe temperature and a time.
|
|