Item No.:
10
|
|
Site:
Other-POOLS/SPAS
|
|
Violation:
THE SHIP IS TAKING SEDIMENTATION SAMPLES OF THE FILTRATION MEDIA TO CHECK FOR EXCESSISVE ORGANIC MATERIALS, BUT THE SEDIMENTATION SAMPLES ARE GRAB SAMPLES INSTEAD OF CORE SAMPLES.
|
|
Recommendation:
6.3.1.1.5
The granular filters shall be opened at least monthly and examined for cracks, mounds, or holes in the filter media. A core sample of the filter media shall be inspected for excessive organic material accumulation using a recommended sedimentation method.
|
|
|
Item No.:
26
|
|
Site:
Other-TASTES
|
|
Violation:
A SMALL AMOUNT OF DEBRIS WAS NOTED ON THE INTERIOR OF ONE OF THE PREVIOUSLY CLEANED UNDERCOUNTER REFRIGERATION UNITS.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
26
|
|
Site:
Other-DECK 9 PANTRY
|
|
Violation:
THREE PREVIOUSLY CLEANED BAR GLASSES WERE FOUND SOILED AND STORED IN THE CLEAN STORAGE RACK.
|
|
Recommendation:
7.5.5.1.1
Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
THE MEIKO POTWASH UNIT HAS BEEN "OUT OF ORDER" FOR AT LEAST TWO MONTHS. PARTS ARE ON ORDER.
|
|
Recommendation:
Repair Meiko Potwash as soon as parts arrive and place unit back in service.
|
|
|
Item No.:
28
|
|
Site:
Other-CREW GALLEY - BUFFET LINE
|
|
Violation:
PLATES AND BOWLS WERE NOT STORED INVERTED.
|
|
Recommendation:
7.5.7.3.2
Clean equipment and utensils shall be stored:
(1) In a self-draining position that allows air drying; and (2) Covered or inverted.
|
|
|
Item No.:
33
|
|
Site:
Other-PREGO GALLEY - HOT LINE
|
|
Violation:
A GAP WAS NOTED ALONG THE BACK OF THE ELKO FLAT TOP GRILL WHERE THIS UNIT MEETS THE STAINLESS STEEL BULKHEAD.
|
|
Recommendation:
7.7.4.2.3
Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
|
|
|
Item No.:
21
|
|
Site:
Other-FOOD SERVICE GENERAL
|
|
Violation:
AN OPEN CELL GASKET WAS NOTED ON THE FRONT ACCESS PANEL OF THE UPPER COMPARTMENT OF THE MANITOWOC ICE MACHINES.
|
|
Recommendation:
7.4.1.1.9
Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material.
|
|
|
Item No.:
34
|
|
Site:
Other-PROVISIONS - FISH & SEAFOOD PREP ROOM
|
|
Violation:
APPROXIMATELY TWO INCHES OF WATER WAS NOTED COVERING THE FLOOR OF THIS ROOM. THE CAUSE OF THIS FLOODING COULD NOT BE DETERMINED. THE WATER IN QUESTION WAS NOT FROM THE GREY OR BLACK WATER SYSTEMS.
|
|
Recommendation:
7.7.3.3.1
A plumbing system in a food area shall be maintained in good repair.
|
|
|
Item No.:
*
|
|
Site:
Other-CORRECTIVE ACTION STATEMENT
|
|
Violation:
IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY.
PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV
USE EMAIL MESSAGE SUBJECT LINE: CRYSTAL SERENITY - CAS -11/20/2004.
|
|
Recommendation:
|
|