Cruise Ship: Silver Whisper Cruise Line: Silversea Inspection Date: 10/29/2004 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: *
Site: Other-GENERAL COMMENT
Violation: THE OVERALL KNOWLEDGE OF ALL CREW IN BOTH THE HOTEL, DECK AND, ENGINE DEPARTMENTS WAS OUTSTANDING.
Recommendation:
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: SILVER WHISPER - CAS - 10/29/2004.
Recommendation:
Item No.: 08
Site: Other-POTABLE WATER
Violation: THE VESSEL DID NOT HAVE A COMPREHENSIVE CROSS-CONNECTION CONTROL PLAN. CURRENTLY THE PLAN ONLY INCLUDED THE TESTABLE REDUCED PRESSURE (RP) PRINCIPLE BACKFLOW PREVENTERS AND NOT THE NON-TESTABLE BACKFLOW PREVENTERS.
Recommendation: Include all backflow prevention devices on the comprehensive cross connection control plan. The frequency of inspection of the non-testable units should be established either by the cruise line or the vessel. 5.7.1.1.3 The vessel shall provide a comprehensive cross- connection control program that provides safe connections to the potable water system through air gaps or appropriate backflow devices at the following locations, if present: (1) Potable water supply lines to swimming pools, whirlpool spas, hot tubs, bathtubs, showers, and similar facilities; (2) Photographic laboratory developing machines and utility sinks; (3) Beauty and barber shop spray-rinse hoses; (4) Potable water faucets where hoses are connected or can be connected by threaded or quick-connect outlets such as those serving tanks containing chlorine and other chemicals, and deck taps; (5) Garbage grinders and pulpers; (6) Mechanical warewashing machines; (7) Hospital and laundry equipment; (8) Air conditioning expansion tanks; (9) Boiler feed water tanks; (10) Fire systems; (11) Toilets; (12) Potable water, bilge, and sanitary pumps that require priming; (13) Freshwater or saltwater ballast systems; (14) Bilge or other waste water locations; (15) International shore connection; and (16) Any other connection between potable and non-potable water systems.
Item No.: 20
Site: Other-PROVISIONS - BUTCHER SHOP
Violation: THE MEAT SAW HAS NOT BEEN USED FOR AT LEAST ONE MONTH. CORROSION WAS ALSO NOTED WITH THE TECHNICAL SPACES OF THIS UNIT.
Recommendation: 7.4.5.1.1.1 Food-contact equipment shall be maintained in good repair and proper adjustment including: (1) Equipment shall be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 20
Site: Other-TERRACE CAFÉ - DECK 7
Violation: THREE CUTTING BOARDS WERE VERY PITTED AND SCORED.
Recommendation: 7.4.5.1.3 Surfaces such as cutting blocks and boards that are subject to scratching and scoring shall be resurfaced if they no longer can be effectively cleaned and sanitized, or discarded if they are not capable of being resurfaced.
Item No.: 20
Site: Other-CREW GALLEY
Violation: THE PASTA BOILER HAS BEEN OUT OF ORDER FOR MORE THAN A WEEK.
Recommendation: 7.4.5.1.1.1 Food-contact equipment shall be maintained in good repair and proper adjustment including: (1) Equipment shall be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 20
Site: Other-CREW GALLEY
Violation: THE FRYER HAS BEEN OUT OF ORDER FOR MORE THAN A WEEK.
Recommendation: 7.4.5.1.1.1 Food-contact equipment shall be maintained in good repair and proper adjustment including: (1) Equipment shall be maintained in a state of repair and condition that meets the materials, design, construction, and operation specifications of these guidelines.
Item No.: 21
Site: Other-MAIN DINNING ROOM - DECK 4
Violation: OPEN SEAMS WERE NOTED AROUND THE HEATING ELEMENT ON THE FLAMBÉ TABLES.
Recommendation: 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Other-MAIN GALLEY - COLD GALLEY
Violation: A PINK SLIME WAS NOTED IN THE DRAIN OF THE COOL DRAFT ICE MACHINE.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Other-CREW GALLEY
Violation: A LOOSE PROFILE WAS NOTED ON THE LEFT SIDE OF THE MKN RANGE.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 33
Site: Other-TERRACE CAFÉ - BUFFET LINE
Violation: THE TILES IN FRONT OF THE ICE MACHINE WERE BROKEN AND CHIPPED.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 33
Site: Other-TERRACE CAFÉ - HOT GALLEY
Violation: AN OPEN SEAM WAS NOTED ON THE LEFT SIDE OF THE RANGE.
Recommendation: 7.7.4.1.4 Bulkheads and deckheads shall have smooth, hard finishes, and light colored surfaces.
Item No.: 33
Site: Other-PROVISIONS - STARBOARD CORRIDOR
Violation: THE DECK TILES WERE BROKEN AND CHIPPED IN THIS ENTRANCE CORRIDOR.
Recommendation: 7.7.4.2.3 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas, shall be maintained in good repair.
Item No.: 33
Site: Other-PROVISIONS - SEAFOOD FREEZER
Violation: THE THRESHOLD FOR THE SEAFOOD FREEZER WAS IN POOR CONDITION.
Recommendation: Repair the walk-in seafood freezer in the starboard entrance corridor.
Item No.: 40
Site: Other-INTEGRATED PEST MANAGEMENT
Violation: THE INTEGRATED PEST MANAGEMENT (IPM) PLAN DID NOT INCLUDE FORMALIZED ACTIVE MONITORING PROCEDURES. IT WAS STATED THAT THIS WAS DONE AS PART OF ROUTINE INSPECTIONS THROUGHOUT THE VESSEL BUT WAS NOT SPECIFICALLY DOCUMENTED. ADDITIONALLY, THE WRITTEN PLAN DID NOT INCLUDE INSPECTIONS OF PROVISIONS COMING ONBOARD. THE INSPECTIONS WERE BEING DONE AND DOCUMENTED ON THE RECEIVING REPORTS MAINTAINED BY THE PROVISIONS MASTER.
Recommendation: Modify the written IPM plan to include active monitoring and inspection of provisions being onboard the vessel. 8.1.1.1.3 The Integrated Pest Management Plan shall include provisions for active monitoring including pest sighting logs for the operational areas of the vessel and training for crew members in charge of log completion. 8.2.1.1.3 Incoming shipments of food and supplies shall be routinely inspected for evidence of insects, rodents, and other pests.