Skip directly to site content Skip directly to page options

Inspection Detail Report

  Advanced Search |  Ship Scored 100 |  Green Sheet  |  CDC Home |  VSP Home
 
Cruise Ship: Wind Spirit Cruise Line: Windstar Cruises Inspection Date: 12/11/2004 Inspection Score: 99
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 20
Site: Other-MAIN GALLEY
Violation: THE COATING ON THE SHELVES IN THE BLAST CHILLER WAS PEELING, MAKING THEM DIFFICULT TO CLEAN.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition. 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 20
Site: Other-MAIN GALLEY
Violation: REFRIGERATOR #13 WAS POSTED OUT OF ORDER. IT WAS STATED THAT THIS HAS BEEN OUT OF ORDER FOR APPROXIMATELY 2 MONTHS.
Recommendation: Repair or replace this unit.
Item No.: 26
Site: Other-MAIN GALLEY
Violation: THE UPPER COMPARTMENT OF THE ICE MACHINE WAS SLIGHTLY SOILED.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 21
Site: Other-MAIN GALLEY
Violation: THE LEFT SIDE HOT PLATE WAS WARPED, CREATING A GAP THAT WAS DIFFICULT TO CLEAN.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material. 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 26
Site: Other-MAIN GALLEY
Violation: ONE STRAINER WAS SOILED AND STORED AS CLEAN IN THE POTWASH.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 33
Site: Other-MAIN GALLEY
Violation: THE AREAS OF THE DECK THAT WERE CONSTRUCTED OF PAINTED STEEL WERE ROUGH AND HAD PEELING PAINT, MAKING THEM DIFFICULT TO CLEAN.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 21
Site: Other-MAIN GALLEY
Violation: A GAP WAS NOTED IN THE GRILL GREASE TRAP AREA, MAKING THIS AREA DIFFICULT TO CLEAN.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material. 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Other-MAIN GALLEY
Violation: THE GAP IN THE GRILL GREASE TRAP AREA WAS SOILED WITH OLD GREASE.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 20
Site: Other-MAIN GALLEY
Violation: ONE FASTENER WAS MISSING ON THE FRYER COILS, MAKING THEM DIFFICULT TO CLEAN.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition. 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 28
Site: Other-MAIN GALLEY
Violation: CLEAN PLASTIC CONTAINERS IN THE DISHWASH AREA WERE NOT STORED IN A MANNER THAT ALLOWED THEM TO BE AIR DRIED.
Recommendation: 7.5.7.1.1 After cleaning and sanitizing, equipment and utensils shall be air-dried or adequately drained before contact with food. 7.5.7.3.2 Clean equipment and utensils shall be stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 26
Site: Other-MAIN GALLEY
Violation: ONE PLASTIC CONTAINER WAS SOILED AND STORED AS CLEAN IN THE DISHWASH.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 26
Site: Other-VERANDAH PANTRY
Violation: THE FASTENERS IN THE UPPER COMPARTMENT OF THE ICE MACHINE WERE SOILED.
Recommendation: 7.5.5.1.1 Food-contact surfaces of equipment and utensils shall be clean to sight and touch.
Item No.: 20
Site: Other-VERANDAH BUFFET LINE
Violation: SLOTTED FASTENERS WERE NOTED ON THE FRYER COILS AND IN THE SPLASH ZONE, MAKING THESE AREAS DIFFICULT TO CLEAN.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition. 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 28
Site: Other-VERANDAH BUFFET
Violation: THE SILVERWARE WAS NOT COVERED ON THE BUFFET LINE. THIS AREA WAS NOT OPEN AT THE TIME OF INSPECTION.
Recommendation: 7.5.7.3.2 Clean equipment and utensils shall be stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 33
Site: Other-POOL BAR
Violation: THE AREAS OF THE DECK THAT WERE CONSTRUCTED OF PAINTED STEEL WERE ROUGH AND HAD PEELING PAINT, MAKING THEM DIFFICULT TO CLEAN.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 27
Site: Other-LOUNGE BAR
Violation: THE TECHNICAL COMPARTMENT CONTAINING THE COOLING LINES FOR THE UNDERCOUNTER REFRIGERATORS WAS SOILED WITH DUST.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 33
Site: Other-BUTCHER SHOP
Violation: THE BULKHEAD NEXT TO REFRIGERATOR #16 WAS DAMAGED, LEAVING A GAP NEAR THE DECK THAT WAS DIFFICULT TO CLEAN.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 15
Site: Other-PROVISIONS
Violation: SIX CANS OF OCEAN CLAMS WERE NOTED IN THE FISH FREEZER. THE ENDS OF THE CANS WERE SWOLLEN, BUT IT WAS DETERMINED THAT THE SWELLING WAS DUE TO THE LIQUID IN THE CANS BEING FROZEN. THESE CANS WERE DISCARDED. IT WAS STATED BY THE CHEF THAT THESE CANS WERE RECEIVED IN ERROR AND WERE NOT GOING TO BE USED.
Recommendation: 7.3.2.2.5 Food packages shall be in good condition and protect the integrity of the contents so that the food is not exposed to adulteration or potential contaminants. Canned goods with dents on end or side seams may not be used.
Item No.: 28
Site: Other-CREW & OFFICER'S MESS ROOMS
Violation: THE PLATES AND SILVERWARE ON THE BUFFET LINES WERE NOT STORED COVERED OR INVERTED. THESE AREAS WERE NOT OPEN AT THE TIME OF INSPECTION.
Recommendation: 7.5.7.3.2 Clean equipment and utensils shall be stored: (1) In a self-draining position that allows air drying; and (2) Covered or inverted.
Item No.: 10
Site: Other-POOL & WHIRLPOOL
Violation: THE DISINFECTION CONTACT TIME AND HALOGEN RESIDUAL WERE NOT LISTED IN THE FECAL ACTION PLAN. THIS WAS CORRECTED DURING THE INSPECTION.
Recommendation: Ensure that the disinfection contact time and halogen residual are listed in the fecal action plan.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: WIND SPIRIT - CAS - 12/11/2004.
Recommendation:
Item No.: 20
Site: Other-FOOD SERVICE GENERAL
Violation: ABSORBENT GASKETS WERE NOTED BETWEEN THE UPPER AND LOWER COMPARTMENTS OF ALL OF THE ICE MACHINES.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition.
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program