Cruise Ship: Wind Surf Cruise Line: Windstar Cruises Inspection Date: 12/11/2004 Inspection Score: 100
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 21
Site: Other-GRILL STATION
Violation: A GAP WAS NOTED AROUND THE GREASE TRAP AREA OF THE GRILL, MAKING IT DIFFICULT TO CLEAN.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material. 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 27
Site: Other-GRILL STATION
Violation: THE GAP IN THE GREASE TRAP AREA OF THE GRILL WAS SOILED.
Recommendation: 7.5.5.1.3 Nonfood-contact surfaces of equipment shall be kept free of an accumulation of dust, dirt, food residue, and other debris.
Item No.: 21
Site: Other-GRILL STATION
Violation: PEELING SEALANT WAS NOTED AT THE BULKHEAD/COUNTER JUNCTURES IN THIS AREA, MAKING THIS AREA DIFFICULT TO CLEAN. THIS WAS CORRECTED DURING THE INSPECTION.
Recommendation: 7.4.1.1.9 Nonfood-contact surfaces of equipment that are exposed to splash, spillage, or other food soiling or that require frequent cleaning shall be constructed of a corrosion-resistant, nonabsorbent, and smooth material. 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 19
Site: Other-VERANDAH RESTAURANT
Violation: SNEEZE GUARDS WERE NOT PROVIDED ON THE SIDES OF THE BUFFET LINES WHERE PASSENGERS LINE UP TO SERVE THEMSELVES.
Recommendation: 7.3.3.6.1 Food on display shall be protected from contamination by the use of packaging; counter, service line, or salad bar food guards; display cases; or other effective means.
Item No.: 20
Site: Other-BISTRO GALLEY
Violation: THE SEAL AROUND THE WINDOW INSIDE OF THE CONVECTION OVEN WAS SPLIT AND CRACKED, MAKING IT DIFFICULT TO CLEAN.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition. 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 20
Site: Other-BISTRO GALLEY
Violation: SLOTTED FASTENERS WERE NOTED ON THE SPLASH ZONE OF THE FRYER, MAKING IT DIFFICULT TO CLEAN. THIS WAS CORRECTED DURING THE INSPECTION.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition. 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 21
Site: Other-BISTRO GALLEY
Violation: THE GREASE TRAP AREA OF THE GRILL WAS SEALED. THIS AREA COULD NOT BE ACCESSED FOR CLEANING.
Recommendation: Ensure that this area of the grill is made accessible for cleaning. 7.4.2.2.6 Nonfood-contact surfaces shall be free of unnecessary ledges, projections, and crevices, and designed and constructed to allow easy cleaning and to facilitate maintenance.
Item No.: 33
Site: Other-BISTRO GALLEY
Violation: PEELING SEALANT WAS NOTED ON THE BULKHEAD IN THE HOT GALLEY AREA, MAKING IT DIFFICULT TO CLEAN.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 20
Site: Other-MAIN GALLEY
Violation: SLOTTED FASTENERS WERE NOTED ON THE SPLASH ZONE OF THE FRYER, MAKING IT DIFFICULT TO CLEAN. THIS WAS CORRECTED DURING THE INSPECTION.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition. 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 20
Site: Other-PREPARATION GALLEY - BAKERY
Violation: A FEW FASTENERS WERE MISSING INSIDE THE DOOR OF THE BAKER'S OVEN, MAKING IT DIFFICULT TO CLEAN.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition. 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 33
Site: Other-PREPARATION GALLEY - DISHWASH
Violation: A PIECE OF THE STAINLESS STEEL PROFILE WAS MISSING AT THE BULKHEAD/DECKHEAD JUNCTURE IN THIS AREA, MAKING IT DIFFICULT TO CLEAN.
Recommendation: 7.7.4.1.1 Decks, bulkheads, and deckheads in food preparation, warewashing, pantries, and storage areas shall be constructed and maintained for easy cleaning.
Item No.: 16
Site: Other-FOOD SERVICE GENERAL
Violation: IT WAS STATED THAT SMOKED SALMON IS SERVED ON BOARD THE VESSEL. THE DOCUMENTATION OF THE FREEZING FOR SMOKED SALMON STATED THAT THE FISH WAS FROZEN TO -15°C (5°F) FOR 168 HOURS OR -29°C (-20°F) FOR 24 HOURS IN A BLAST FREEZER. THESE TEMPERATURES AND TIMES ARE NOT SUFFICIENT FOR PARASITE DESTRUCTION IF THIS FISH IS TO BE SERVED IN READY-TO-EAT FORM, RAW, RAW-MARINATED, PARTIALLY COOKED, OR MARINATED-PARTIALLY COOKED.
Recommendation: 7.3.4.2.1 Before service in ready-to-eat form, raw, raw-marinated, partially cooked, or marinated-partially cooked fish other than molluscan shellfish: (1) Shall be frozen throughout to a temperature of -20°C (-4°F) or below for 168 hours (7 days) in a freezer; or -35°C (-31°F) or below for 15 hours in a blast freezer. 7.3.4.2.2 If raw, raw-marinated, partially cooked, or marinated-partially cooked fish are served in ready-to-eat form: (1) The person in charge shall record the freezing temperature and time to which the fish are subjected and shall retain the records on the vessel for 90 calendar days beyond the time of service or sale of the fish; or (2) If the fish are frozen by a supplier, a written agreement or statement from the supplier stipulating that the fish supplied are frozen to a safe temperature and a time.
Item No.: 20
Site: Other-FOOD SERVICE GENERAL
Violation: LARGE GAPS AND SEAMS AND OTHER DIFFICULT TO CLEAN FEATURES WERE NOTED ON ALL OF THE ICE MACHINES ON THE VESSEL. THIS WAS NOTED ON THE LAST INSPECTION, HOWEVER THE VESSEL HAS ORDERED NEW ICE MACHINES THAT ARE TO BE DELIVERED 1/16/2005.
Recommendation: 7.4.1.1.2 Materials that are used in the construction of multiuse utensils and food-contact surfaces of equipment shall be: (1) Durable, corrosion-resistant, and nonabsorbent; (2) Sufficient in weight and thickness to withstand repeated warewashing; (3) Finished to have a smooth, easily cleanable surface; and (4) Resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition. 7.4.2.2.1 Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams >1 mm (1/32 inch), cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Accessible for cleaning and inspection by one of the following methods without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
Item No.: 10
Site: Other-POOLS & WHIRLPOOLS
Violation: THE DISINFECTION CONTACT TIME AND HALOGEN RESIDUAL LISTED IN THE FECAL ACCIDENT RESPONSE PROCEDURE WERE NOT SUFFICIENT TO ADDRESS LOOSE STOOLS.
Recommendation: Ensure that the disinfection contact time and halogen residual are sufficient to address loose stools.
Item No.: 10
Site: Other-WHIRLPOOLS
Violation: A CORE SAMPLE WAS NOT BEING CONDUCTED FOR THE MONTHLY SEDIMENTATION TESTS.
Recommendation: 6.3.1.1.5 The granular filters shall be opened at least monthly and examined for cracks, mounds, or holes in the filter media. A core sample of the filter media shall be inspected for excessive organic material accumulation using a recommended sedimentation method.
Item No.: *
Site: Other-CORRECTIVE ACTION STATEMENT
Violation: IN DEVELOPING THE CORRECTIVE ACTION STATEMENT FOR THIS INSPECTION, CRITICAL-ITEM DEFICIENCIES (DESIGNATED WITH YES IN CRITICAL COLUMN (WORTH 3 - 5 POINTS), WHETHER DEBITED OR NOT, SHOULD INCLUDE STANDARD OPERATING PROCEDURES AND MONITORING PROCEDURES IMPLEMENTED TO PREVENT THE RECURRENCE OF THE CRITICAL DEFICIENCY. PREPARE CORRECTIVE ACTION STATEMENT AS A WORD PROCESSING OR SPREADSHEET FILE WHICH WILL BE SENT TO USPHS / VSP AS AN EMAIL MESSAGE ATTACHMENT. PLEASE EMAIL CORRECTIVE ACTION STATEMENT TO: VSP@CDC.GOV USE EMAIL MESSAGE SUBJECT LINE: WIND SURF - CAS - 12/11/2004.
Recommendation:
*Inspections scores of 85 or lower are NOT satisfactory
Vessel Sanitation Program