|
|
|
Item No.:
5
|
|
Site:
Other-POTABLE WATER SYSTEM
|
|
Violation:
The bunker hose was lying on the dock, uncapped prior to hook-up. The other end was lying in the bunker station uncapped. A "keeper chain" was not provided for the cap to the bunker line.
|
|
Recommendation:
Potable water hoses must be flushed before the filling line is attached. Hoses must be drained after each use and stowed, with ends capped, on reels or racks in special lockers marked "POTABLE WATER HOSE AND FITTINGS STORAGE" in letters at least one-half inch high. Lockers must be closed self-draining, smooth, nontoxic, corrosion-resistant, easily cleanable, fixed 18-inches above the deck and used for no other purpose. Hoses and fittings must be maintained in good repair. All fittings and other appurtenances used in connection with the loading of potable water must be handled and stored in a sanitary manner. The potable water filling line should begin either horizontally or in a gooseneck position pointing downwards, at a point at least 18-inches above the top of the tank or of the deck that the line penetrates. The filling line must have a screw cap or plug fastened by a chain to an adjacent bulkhead or surface in such a manner that the cap or plug will not touch the deck when hanging free.
|
|
|
Item No.:
3
|
|
Site:
Other-POTABLE WATER SYSTEM
|
|
Violation:
Recorder charts for the potable water distribution system were not available for each day of operation. For the 17 days of January, 1993, only 7 charts were available. The crew stated that the recorder had not been working properly.
|
|
Recommendation:
The analyzer and chart recorder must be properly maintained, operated and calibrated in accordance with the manufacturer's instructions. A review of records from the ship's automatic chlorine or bromine analyzer must show that the ship has maintained adequate amounts of free halogen residual in the water distribution system since the last inspection of the vessel. The review will be deemed unacceptable if the records show a free halogen residual of less than 0.2 ppm for more than 24 consecutive hours. Charts shall be initialed and dated daily and retained for at least 12-months. In the event of unexpected equipment failure, manual methods for halogenation and for determination of halogen residuals may be used temporarily provided that halogen residuals are measured at least once every 8-hours. In such situations, ships must repair the malfunctioning equipment within 10-days. This privilege may be rescinded if abused by ship's staff.
|
|
|
Item No.:
38
|
|
Site:
Other-VERANDAH PANTRY
|
|
Violation:
Loose bulkhead and deckhead profile strips resulted in open seams. Also, some cracked and missing sealant was noted where the bulkhead tiles joined the stainless steel deckhead panels.
|
|
Recommendation:
Decks, bulkheads, and deckheads in food preparation, warewashing, and storage areas, including pantries, shall be designed and constructed for easy cleanability, shall be corrosion-resistant, maintained in good repair, and kept clean.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The final rinse temperatures of the dishwasher and the glasswasher were 160o and 152oF.
|
|
Recommendation:
Automatic dishwashing machines utilizing hot water for sanitizing shall operate at a minimum of 165oF (74oC) measured at dish level.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
There was a rough seam on the tilting skillet and the cover was in poor repair.
|
|
Recommendation:
Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, should be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and should be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
|
|
|
Item No.:
21
|
|
Site:
Other-COLD KITCHEN
|
|
Violation:
There was a gap in the meat slicer that was not cleanable.
|
|
Recommendation:
Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, should be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and should be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
|
|
|
Item No.:
20
|
|
Site:
Other-COLD KITCHEN
|
|
Violation:
It is recommended that since the 3-compartment sink is not being used, it should be removed and replaced with a blast chiller that would greatly enhance the refrigeration capabilities of the galley.
|
|
Recommendation:
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY & LIDO FOOD S
|
|
Violation:
The compressors in the ice machines are rusted and are staining the machines. Gaps and old caulking make these machines difficult to clean.
|
|
Recommendation:
These ice machines should be replaced.
|
|
|
Item No.:
21
|
|
Site:
Other-FOOD SERVICE-GENERAL
|
|
Violation:
Numerous refrigerator door gaskets were in poor repair.
|
|
Recommendation:
Refrigerator gaskets shall be easily cleanable without breaks in the material. The corners shall be closed and sealed and hollow sections shall be sealed.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Profile strips were loose in the exhaust hoods making these areas difficult to clean.
|
|
Recommendation:
Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, should be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and should be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Open seams existed on top of the ranges that were difficult to clean.
|
|
Recommendation:
Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, should be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and should be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Several previously cleaned plate covers were soiled with food residue.
|
|
Recommendation:
To ensure clean platecovers, the platecovers shall be prewashed, correctly racked, and if necessary, presoaked to facilitate thorough wash, rinse and sanitizing action in the dishwashing machine. Any items that are found to be soiled must be returned to the dishwashing area for immediate rewashing.
|
|
|
Item No.:
14
|
|
Site:
Other-LIDO FOOD SERVICE
|
|
Violation:
No sneeze shields were provided for the buffet table.
|
|
Recommendation:
Display tables or buffet lines for service of unpackaged foods must be effectively shielded so as to intercept any source of contamination from the consumer. Appropriate food shielding (sneeze guards) should be provided.
|
|
|
Item No.:
38
|
|
Site:
Other-LOUNGE BAR
|
|
Violation:
The deck tiles were cracked and broken.
|
|
Recommendation:
It is recommended that decks be maintained so as to be durable and easily cleanable.
|
|