Item No.:
14
|
|
Site:
Other-LIDO BUFFET
|
|
Violation:
Protective food shielding (sneeze guards) were not provided for the self-service food display.
|
|
Recommendation:
Display tables or buffet lines for service of unpackaged foods must be effectively shielded so as to intercept any source of contamination from the consumer. Appropriate food shielding (sneeze guards) must be provided.
|
|
|
Item No.:
20
|
|
Site:
Other-LIDO BUFFET & LOUNGE BAR
|
|
Violation:
The interior of the ice machine had open seams, rust and rough sealant which created difficult-to-clean surfaces.
|
|
Recommendation:
Food-contact surfaces must be easily cleanable and free of difficult-to-clean internal corners, crevices, and fasteners. The ice machine shall be replaced.
|
|
|
Item No.:
28
|
|
Site:
Other-LIDO BUFFET & LOUNGE BAR
|
|
Violation:
The interior of the ice machine had a small accumulation of black mold on its' surfaces.
|
|
Recommendation:
All food and ice preparation and dispensing equipment shall be effectively washed, rinsed, and sanitized after every use, change in use or when soil begins to appear on the surfaces. A food surface is that surface of equipment or utensil with which food normally comes in contact and those surfaces from which food may drip, drain, or splash back onto other surfaces normally in contact with food.
|
|
|
Item No.:
20
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Rough welds were noted on the food preparation countertops. Sealant was used to fill the openings.
|
|
Recommendation:
All food preparation surfaces of equipment shall be smooth and free of imperfections such as rough welds, pits, holes, and open seams. These surfaces shall be re-welded and ground smooth. Also, sealant shall not be used on food contact surfaces of equipment.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY & WINE STORE
|
|
Violation:
Ropes were being used to hold glass racks in place during ship movement.
|
|
Recommendation:
The ropes are absorbant and therefore, not easily cleanable. They must be replaced with stainless steel chains.
|
|
|
Item No.:
21
|
|
Site:
Other-BUTCHER SHOP
|
|
Violation:
The door threshold at the entrance to the room and the stainless steel moulding in the outside corridor were in poor repair.
|
|
Recommendation:
The door threshold and the moulding shall be re-installed or replaced to provide a smooth and easily cleanable surface.
|
|
|
Item No.:
21
|
|
Site:
Other-ROOM SERVICE PANTRY
|
|
Violation:
An undercounter dishwashing machine with a pre-wash sink and clean storage shelving were not provided for the room.
|
|
Recommendation:
For convenience and accessibility to glass and dishwashing facilities, the equipment must be provided. Equipment must be constructed of stainless steel and installed to facilitate cleaning of all adjacent bulkhead and deck surfaces.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Open seams and gaps were noted where pieces of equipment join.
|
|
Recommendation:
All open seams and gaps shall be either sealed with an approved sealant or provided with profile strips. Any openings of 3/8" or greater must be provided with stainless steel profile strips.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN DISHWASHING
|
|
Violation:
The drain covers were not affixed to prevent tipping of the covers and a tripping hazard.
|
|
Recommendation:
The drain covers shall be welded in place.
|
|
|
Item No.:
20
|
|
Site:
Other-CREW MESS
|
|
Violation:
Open seams were noted in the food preparation counter. Also, shelving was not provided for the undercounter refrigerators.
|
|
Recommendation:
The open seams shall be welded and ground smooth. Removable and easily cleanable stainless steel shelving shall be provided for the refrigerators.
|
|
|
Item No.:
28
|
|
Site:
Other-OFFICERS' MESS
|
|
Violation:
The fruit bowl was found with food residue on its' surfaces.
|
|
Recommendation:
Food should be prepared or stored on surfaces that prior to use have been effectively washed, rinsed and sanitized.
|
|
|
Item No.:
20
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Open seams were present around the can opener support bracket. Also, holes and open seams were present in the tabletop where the Salamander was removed.
|
|
Recommendation:
Food-contact surfaces of equipment must be easily cleanable and free of difficult-to-clean internal corners, open seams, rough welds, and crevices.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The interior of the cabinet to the tilting fryer had rough welds which presented non-easily cleanable surfaces.
|
|
Recommendation:
Surfaces of equipment not intended for contact with food, but which are exposed to splash or food debris or which otherwise require frequent cleaning, should be designed and fabricated to be smooth, washable, free of unnecessary ledges, projections, or crevices, and readily accessible for cleaning, and should be of such material and in such repair as to be easily maintained in a clean and sanitary condition.
|
|