Item No.:
4
|
|
Site:
Other-POTABLE WATER SYSTEM
|
|
Violation:
The following connections to the potable water system were not protected against backflow:
- The Beauty Salon, Pool, and Spa shower rinse hoses.
- The Photo Lab and Laundry room sink faucets.
- The Pool area water faucet.
- The main laundry and passenger laundry machines.
- The water supply to the boiler feed tank.
|
|
Recommendation:
When potable water is supplied under pressure, the system must be protected against backflow or other contamination by vacuum breakers, backflow preventers, or air gaps between the delivery point of the water and the overflow rim of the unit. Vacuum breakers or backflow preventers must be installed when air gaps are imipractical or when water under pressure is required. Vacuum breakers, when used, must be installed in the supply lines on the discharge side of the last control valve at least 6-inches above the flood-level rim of the fixture to protect the potable water system from potential contamination.
|
|
|
Item No.:
6
|
|
Site:
Other-WHIRLPOOL BATHS
|
|
Violation:
The free halogen residual in the whirlpools was 0.5 parts-per-million. Also, halogen residual logs were not maintained with residuals measured and recorded every 4-hours of operation.
|
|
Recommendation:
Whirlpool, spa and hot tub water must be filtered and a free halogen residual of 2.0-5.0 ppm must be maintained. Suitable test equipment should be used to monitor the halogen residual. Halogen residual logs shall be maintained with residuals measured and results recorded every 4-hours of operation. The log will be retained for at least 12-months.
|
|
|
Item No.:
1
|
|
Site:
Other-POTABLE WATER SYSTEM
|
|
Violation:
Bunkered water was not halogenated to at least 2 parts-per-million before entering the tanks. Bunkered and produced water was batch halogenated through a funnel in the main bunkering line. A chlorination pump was not provided. Also, a sample cock located after the chlorine addition, for the purpose of measuring and monitoring the level of halogenation, was not provided.
|
|
Recommendation:
Batch halogenation of bunkered water is not recommended. The approved method of disinfecting bunkered water is continuous halogenation with an automatic hypochlorinator or brominator. Batch chlorination or bromination is acceptable in the following types of emergencies: a) equipment failure; b) contaminated systems; (c) plumbing or tank repairs. Water samples obtained from either a sample cock between the bunkering halogenators and the storage tanks or from tanks into which potable water has been bunkered (including water produced on board from a distillation system) must have a free halogen residual of at least 2 ppm.
|
|
|
Item No.:
35
|
|
Site:
Other-BARS
|
|
Violation:
Paper towels were not provided at the handwashing sinks. A shared cloth was used multiple times by bar personnel for hand drying.
|
|
Recommendation:
A supply of paper towels shall be conveniently located near each handwashing sink at all times.
|
|
|
Item No.:
26
|
|
Site:
Other-BARS
|
|
Violation:
In those bars without dishwashing machines, a two-compartment sink was used for manual washing of bar equipment. The equipment was not being sanitized.
|
|
Recommendation:
The food contact surfaces of all equipment and utensils shall be sanitized by either immersion for at least 30 seconds in clean water at a temperature of at least 170oF, or by immersion for at least one minute in clean water containing at least 50 ppm of available chlorine and at a temperature of at least 75oF.
|
|
|
Item No.:
14
|
|
Site:
Other-BARS
|
|
Violation:
Airgaps or air breaks were not provided in the bar sink drainlines.
|
|
Recommendation:
Drain lines from sinks used in the cleaning and sanitizing of utensils and equipment and in food preparation, including ice-holding sinks, shall be indirectly connected to the drainage system by means of an air gap or air break.
|
|
|
Item No.:
21
|
|
Site:
Other-MIDSHIP BAR
|
|
Violation:
The coffee machine was not raised at least 4-inches from the tabletop to allow for proper cleaning under the unit.
|
|
Recommendation:
Equipment that is placed on tables or counters, unless portable, shall be sealed to the table or counter or elevated on legs to provide at least a 4-inch clearance between the table or counter and shall be installed to facilitate the cleaning of the equipment and adjacent areas.
|
|
|
Item No.:
22
|
|
Site:
Other-DOLPHIN HALL BAR
|
|
Violation:
The dishwashing machine did not have an automatic soap dispenser. It was reported that detergent was added manually at the start of daily operations.
|
|
Recommendation:
Dishwashing machines shall be operated in accordance with manufacturers' instructions, and all automatic detergent dispensers, wetting agent dispensers, and liquid sanitizer injectors shall be properly installed and maintained.
|
|
|
Item No.:
21
|
|
Site:
Other-DOLPHIN HALL BAR
|
|
Violation:
There were gaps present between the dishwasher, ice machine, and bar equipment counter that were not easily cleanable. There were also gaps under the dishwasher and ice machine that were not easily cleanable.
|
|
Recommendation:
Unless sufficient space is provided for easy cleaning between, behind and above each unit of fixed equipment, the space between it and adjoining equipment and adjacent bulkheads or deckheads shall be not more than 1/32-inch. If exposed to seepage, the equipment shall be sealed to the adjoining equipment or adjacent bulkheads or deckheads.
|
|
|
Item No.:
38
|
|
Site:
Other-DOLPHIN HALL BAR
|
|
Violation:
A deck coving was not provided between the vinyl deck flooring and the wooden base of the bar equipment. There were seams at the juncture of the floor and equipment base that were not easily cleanable.
|
|
Recommendation:
Surfaces subject to routine splashes, spillage, or other soiling during normal use shall have easily cleanable surfaces. Decks shall be coved at the interfaces between bulkheads or equipment bases.
|
|
|
Item No.:
14
|
|
Site:
Other-DINING ROOM
|
|
Violation:
Foods displayed on the self-service tables were not protected from contamination by sneeze guards.
|
|
Recommendation:
Display tables or buffet lines for service of unpackaged foods must be effectively shielded so as to intercept any source of contamination from the consumer. Appropriate food shielding (sneeze guards) should be provided.
|
|
|
Item No.:
22
|
|
Site:
Other-DINING ROOM PANTRY
|
|
Violation:
Tea pots were being washed in a utility sink. The three step cleaning method was not followed.
|
|
Recommendation:
For manual washing, rinsing, and sanitizing of utensils and equipment, a sink with at least three compartments shall be provided and used. Sink compartments shall be large enough to contain the equipment and utensils, and each compartment of the sink shall be supplied with hot and cold potable running water. Manual washing, rinsing, and sanitizing shall be conducted in the following manner:
- Equipment shall be washed in the first compartment with a hot detergent solution that is kept clean.
- Equipment shall be rinsed free of detergent with clean water in the second compartment.
- Equipment shall be sanitized in the third compartment.
|
|
|
Item No.:
26
|
|
Site:
Other-DINING ROOM PANTRY
|
|
Violation:
The teapots being washed in the utility sink were not sanitized as required.
|
|
Recommendation:
Equipment and utensils shall be sanitized by immersion for at least 30 seconds in clean water at a temperature above 170oF, or by immersion for at least 1 minute in clean water containing at least 50 ppm of available chlorine and at a temperature above 75oF.
|
|
|
Item No.:
19
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Employees were not washing their hands before performing food preparation activities.
|
|
Recommendation:
It is required that food service employees wash their hands as often as necessary to insure that their hands are kept clean at all times. All food-handling personnel must wash their hands when reporting to work, after each visit to the toilet, after each break, after handling raw meat, poultry or seafood and after coughing, sneezing, or handling garbage or similar sources of potential contamination of hands. After handling dirty dishes, staffers must wash their hands again before handling clean dishes and utensils.
|
|
|
Item No.:
26
|
|
Site:
Other-MAIN GALLEY SCULLERY
|
|
Violation:
The final sanitizing rinse temperature of the automatic dishwashing machine was 140oF.
|
|
Recommendation:
Automatic dishwashing machines utilizing hot water for sanitizing shall operate at a minimum of 165oF (74oC) measured at dish level.
|
|
|
Item No.:
27
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Moist cloths were used for general cleaning of food contact surfaces and were not placed in a sanitizing solution between uses. The three step cleaning method was not used.
|
|
Recommendation:
Moist cloths or sponges used for wiping food spills on kitchenware and food-contact surfaces of equipment shall be clean and rinsed frequently in one of the sanitizing solutions specified in Item 26 of the "Vessel Sanitation Operations Manual", August 1989. They shall be used for no other purpose and will be kept in the sanitizing solution between uses.
|
|
|
Item No.:
35
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The handwashing sinks were not equipped with paper towels and trash bins.
|
|
Recommendation:
Handwashing facilities shall include soap, a suitable soap dispenser, single-service paper towels, a suitable towel dispenser, and a suitable waste receptacle.
|
|
|
Item No.:
4
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Hoses were connected to sink faucets that were not protected with backflow preventers.
|
|
Recommendation:
Sink faucets that are connected with hoses must be protected against backflow or other contamination by vacuum breakers. Vacuum breakers must be properly installed and maintained in good repair at all times to assure reliable operation.
|
|
|
Item No.:
29
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The interior ledges of the exhaust hoods were heavily soiled with grease and food residue.
|
|
Recommendation:
Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Large gaps existed between the steamers and between the steamers and the bulkhead. These gaps were not easily cleanable.
|
|
Recommendation:
Unless sufficient space is provided for easy cleaning between, behind and above each unit of fixed equipment, the space between it and adjoining equipment and adjacent bulkheads or deckheads shall be not more than 1/32-inch. If exposed to seepage, the equipment shall be sealed to the adjoining equipment or adjacent bulkheads or deckheads.
|
|
|
Item No.:
29
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The gaps between the steamers were filled with grease and food residue.
|
|
Recommendation:
The gaps must be sealed to prevent the accumulation of food particles and grease.
|
|
|
Item No.:
28
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
A can opener blade was heavily soiled with food residue.
|
|
Recommendation:
All food preparation equipment, utensils, tableware, other food contact surfaces and food storage containers shall be washed, rinsed, and sanitized after every use or change in use. A food surface is that surface of equipment or utensil with which food normally comes in contact and those surfaces from which food may drip, drain, or splash back onto other surfaces normally in contact with food.
|
|
|
Item No.:
30
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Rags, boots, and a soiled apron were stored on the same shelf with clean pans.
|
|
Recommendation:
Cleaned and sanitized equipment and utensils shall be handled and stored in a way that protects them from contamination. Cleaned and sanitized utensils and equipment shall be stored at least 6-inches above the floor, or on moveable dish or glass dolly racks, in a clean, dry location in a way that protects them from contamination from splashes, dust, and other sources.
|
|
|
Item No.:
41
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Soiled cardboard was placed on several storage shelves.
|
|
Recommendation:
Only articles necessary for the food service operation shall be stored in food preparation and storage areas. The cardboard pieces must be discarded.
|
|
|
Item No.:
21
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Several unfinished wooden storage shelves were present throughout the Galley.
|
|
Recommendation:
Nonfood preparation equipment must be easily cleanable, in good repair, and corrosion-resistant.
|
|
|
Item No.:
29
|
|
Site:
Other-MAIN GALLEY KETTLE AREA
|
|
Violation:
The pipe insulation was soiled and in poor repair.
|
|
Recommendation:
The pipe insulation shall be replaced and maintained clean and in good repair.
|
|
|
Item No.:
17
|
|
Site:
Other-MAIN GALLEY KETTLE AREA
|
|
Violation:
Soiled kettle paddles were stored in buckets of water.
|
|
Recommendation:
Between uses during service, food-dispensing utensils shall be stored in the food with the dispensing utensil handle extended out of the food, stored clean and dry or stored in running water. The storage of ice and food dispensing utensils in standing water is prohibited.
|
|
|
Item No.:
20
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Several wooden paddles and other wooden utensils were split and contained gaps that accumulated soil.
|
|
Recommendation:
Food-contact and ice-contact surfaces must be constructed of materials that are nontoxic, smooth, corrosion-resistant, nonabsorbent, and durable under conditions of normal use. Food-contact surfaces also must be easily cleanable and free of difficult-to-clean internal corners, crevices, and fasteners.
|
|
|
Item No.:
30
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Several workers were observed towel drying utensils and equipment that had just been washed.
|
|
Recommendation:
After sanitizing, all equipment and utensils shall be air dried. Cleaned and sanitized equipment and utensils shall be handled and stored in a way that protects them from contamination.
|
|
|
Item No.:
38
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The decks under the stoves, ovens, and fryers were soiled with food debris and grease.
|
|
Recommendation:
Decks, bulkheads, and deckheads shall be kept clean.
|
|
|
Item No.:
10
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Fish baked earlier in the morning for lunch service was found with an internal product temperature of 80oF.
|
|
Recommendation:
After being cooked or prepared, potentially hazardous foods either must be properly refrigerated in a unit with an air temperature at or below 40oF (4.5oC) or remain heated at or above 140oF (60oC).
|
|
|
Item No.:
11
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The baked fish was not cooled rapidly after preparation.
|
|
Recommendation:
Food must be prepared and served immediately after preparation. If cooked food is not going to be served immediately, then it must be cooled rapidly. Potentially hazardous food must be refrigerated in a manner that promotes rapid cooling. Such foods prepared in large volumes or quantities can be rapidly cooled utilizing such methods as shallow pans, agitation, quick chilling in freezer units, or ice baths external to the food container. The use of blast freezers are very effective in reducing temperatures quickly.
|
|
|
Item No.:
15
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Raw shell eggs, raw poultry, and raw meats were stored with ready-to-eat foods in the refrigerators.
|
|
Recommendation:
Because of the possibility of cross-contamination, cooked or ready-to-eat foods and raw poultry, meat or seafood must be stored either in separate refrigerators or freezers, in separate sections of the same refrigerator or freezer or on different shelves of the same refrigerator or freezer with cooked or ready-to-eat foods always stored above raw food.
|
|
|
Item No.:
22
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
A separate pot and pan washing area was not provided on the vessel. A two-compartment sink in the preparation area was used for pot and pan washing. Also, space was not provided to store dirty pots and pans.
|
|
Recommendation:
For manual washing, rinsing, and sanitizing of utensils and equipment, a sink with at least three compartments shall be provided and used. Sink compartments shall be large enough to contain the equipment and utensils, and each compartment of the sink shall be supplied with hot and cold potable running water. Sufficient storage space for clean and dirty pots and pans must be provided to avoid contamination of cleaned equipment.
|
|
|
Item No.:
14
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
The drain lines from the food preparation sinks were not provided with air gaps or air breaks.
|
|
Recommendation:
Drain lines from all fixtures, appliances, compartments, refrigeration units or devices that are used, designed for, or intended to be used in the preparation, processing, storage or handling of food, ice or drinks shall be indirectly connected to appropriate waste systems by means of an air gap or air break.
|
|
|
Item No.:
41
|
|
Site:
Other-MAIN GALLEY
|
|
Violation:
Cleaning lockers were not provided in the Galley for the storage of cleaning supplies and equipment.
|
|
Recommendation:
Lockers, cabinets or undersink shelves in as many areas as necessary shall be provided for the storage of cleaning materials and housekeeping supplies. They shall be labeled "CLEANING SUPPLIES ONLY".
|
|
|
Item No.:
37
|
|
Site:
Other-PROVISIONS
|
|
Violation:
Cans of spray insecticide were located in various areas of the garbage room.
|
|
Recommendation:
Poisonous or toxic materials shall not be stored or used in a way that contaminates food, equipment, or utensils, in a way that constitutes a hazard to employees or other persons, or in a way other than in full compliance with the manufacturer's labeling.
|
|
|
Item No.:
14
|
|
Site:
Other-PROVISIONS
|
|
Violation:
A fruit and vegetable cleaning and preparation room, separate from the Galley, was not provided.
|
|
Recommendation:
To prevent contamination from soiled boxes or soiled produce, it is recommended to unpack, wash, and prepare fruits and vegetables in a separate room or area.
|
|