Item No.:
14
|
|
Site:
Other-MAIN GALLEY - BAKERY/PAST
|
|
Violation:
Several trays of bread and pastries were stored uncovered on a trolley.
|
|
Recommendation:
Food must be protected from potential sources of contamination while in storage. Use of plastic wrap is acceptable for covering the food.
|
|
|
Item No.:
27
|
|
Site:
Other-MAIN GALLEY - COLD PANTRY
|
|
Violation:
Wiping cloths were stored on a preparation counter in between uses.
|
|
Recommendation:
Moist cloths or sponges used for wiping food spills on kitchenware and food contact surfaces of equipment shall be clean and must be rinsed frequently in a sanitizing solution and used for no other purpose. Wiping cloths and sponges shall be stored in a sanitizing solution between uses.
|
|
|
Item No.:
15
|
|
Site:
Other-FISH PREPARATION
|
|
Violation:
Raw fish was stored above ready-to-eat butter in the refrigerator.
|
|
Recommendation:
Because of the possibility of cross-contamination, cooked or ready-to-eat foods and raw poultry, meat or seafood must be stored either in separate refrigerators or freezers, in separate sections of the same refrigerator or freezer or on different shelves of the same refrigerator or freezer with cooked or ready-to-eat foods always stored above raw food.
|
|
|
Item No.:
15
|
|
Site:
Other-BUTCHER SHOP
|
|
Violation:
Raw pork was stored above raw beef in the refrigerator.
|
|
Recommendation:
When it becomes necessary to store various types of raw meats on the same shelving, then beef shall be stored on the top, followed by pork, and then poultry on the bottom. This is based on the required minimum cooking temperatures for meat.
|
|
|
Item No.:
15
|
|
Site:
Other-MAIN GALLEY - COLD PANTRY
|
|
Violation:
Raw shell eggs were stored above ready-to-eat food such as beets and mushrooms.
|
|
Recommendation:
Because of the possibility of cross-contamination, cooked or ready-to-eat foods and raw poultry, meat or seafood must be stored either in separate refrigerators or freezers, in separate sections of the same refrigerator or freezer or on different shelves of the same refrigerator or freezer with cooked or ready-to-eat foods always stored above raw food.
|
|
|
Item No.:
21
|
|
Site:
Other-COLD PANTRY
|
|
Violation:
An open seam was noted between the refrigerator and the bulkhead.
|
|
Recommendation:
Unless sufficient space is provided for easy cleaning between, behind and above each unit of fixed equipment, the space between it and adjoining equipment and adjacent bulkheads or deckheads shall be not more than 1/32-inch. If exposed to seepage, the equipment shall be sealed to the adjoining equipment or adjacent bulkheads or deckheads.
|
|
|
Item No.:
39
|
|
Site:
Other-MAIN HOT GALLEY
|
|
Violation:
Lighting was less than 20-footcandles or 220 lux above the ranges and in the middle of the soup kettle station and on the service counter in the Service Pantry.
|
|
Recommendation:
It is required that additional lighting be provided to insure at least 20-footcandles or 220 lux of light on all food preparation and service counters.
|
|
|
Item No.:
15
|
|
Site:
Other-DAIRY PROVISION & MEAT FR
|
|
Violation:
Raw shell eggs were stored above milk in the Dairy provision. Also a box of raw fish was sitting on a box of raw beef in the meat freezer.
|
|
Recommendation:
Because of the possibility of cross-contamination, cooked or ready-to-eat foods and raw poultry, meat or seafood must be stored either in separate refrigerators or freezers, in separate sections of the same refrigerator or freezer or on different shelves of the same refrigerator or freezer with cooked or ready-to-eat foods always stored above raw food. When storing fish and beef on the same shelving, then beef shall be stored on top.
|
|
|
Item No.:
3
|
|
Site:
Other-POTABLE WATER SYSTEM
|
|
Violation:
The recorder and analyzer for the potable water system showed readings for free halogen residuals between 0.5-0.6 parts per million. The actual test found zero parts per million free halogen residual. (Corrected During Inspection)
|
|
Recommendation:
The analyzer and chart recorder must be properly maintained, operated and calibrated in accordance with the manufacturer's instructions. The manual test must compare within 0.2 parts per million of the readings on the analyzer and chart recorder. The manual test shall be taken at least once per day by ship staff.
|
|
|
Item No.:
4
|
|
Site:
Other-POTABLE WATER SYSTEM
|
|
Violation:
Either an airgap or a backflow prevention device must be provided on the discharge line from the evaporators to the technical tank.
|
|
Recommendation:
|
|
|
Item No.:
4
|
|
Site:
Other-SWIMMING POOL
|
|
Violation:
Either an airgap or a backflow prevention device must be provided on the potable water line in the filter room. If potable water is not used, then the line shall be disconnected.
|
|
Recommendation:
|
|
|
Item No.:
40
|
|
Site:
Other-MAIN SCULLERY AND POTWASH
|
|
Violation:
The extraction of heat and humidity from the warewashing machine and sanitize compartment of the potwash sink should be improved. The areas are very hot and humid while in operation. A chemical sanitize of 50-100 ppm chlorine at a temperature of 75-100oF may be used for sanitizing at the potwash station. This would reduce the heat and humidity in the area.
|
|
Recommendation:
|
|