Cruise Ship: Wind Spirit Cruise Line: Windstar Cruises Inspection Date: 02/25/1996 Inspection Score: 85
This cruise ship inspection report lists deficiencies found during the inspection. Additional information corresponding to each item number is available in the latest edition of the VSP Environmental Public Health Standards.

View/Print Summary Report  |  View/Print Corrective Action Statement
Item No.: 10
Site: Other-MAIN GALLEY
Violation: Three pans of gravy which were cooked and refrigerated the previous day were found in a reach-in refrigerator with the following temperatures: a) One pan of gravy had an internal product temperature of 55oF. b) Two pans of gravy had internal product temperatures of 44 and 45oF., respectively.
Recommendation: The internal temperature of potentially hazardous foods stored in refrigerators shall be checked and must not exceed 45oF (7oC) after allowing for stabilization at refrigerator temperature. The maximum amount of time that a potentially hazardous food is allowed to be out of temperature during the cool down period (45oF to 140oF or 7oC to 60oC) is 4 hours. Potentially hazardous foods of large volume or prepared in large quantities, shall be rapidly cooled utilizing such methods as shallow pans, agitation, quick chilling or water circulation external to the food container. The cooling period shall not exceed 4 hours. The use of blast coolers should be considered.
Item No.: 11
Site: Other-MAIN GALLEY
Violation: At least one of the pans of gravy and probably all three of them were not rapidly cooled to 45oF or below within the required maximum four hour period.
Recommendation: Potentially hazardous food must be refrigerated in a manner that promotes rapid cooling. Such foods prepared in large volumes or quantities can be rapidly cooled utilizing such methods as shallow pans, agitation, quick chilling in freezer units, or ice baths external to the food container. The use of blast freezers are very effective in reducing temperatures quickly. In addition, food thermometers must be used for monitoring temperatures during the cool down process.
Item No.: 39
Site: Other-MAIN GALLEY
Violation: Two light fixture shields located above the hot ranges were warped from exposure to the heat.
Recommendation: All light bulbs in the area of food handling and preparation must be effectively shielded to protect against breakage and possible contamination of food. The shields shall be replaced.
Item No.: 29
Site: Other-MAIN GALLEY
Violation: The lower cabinet to the deep fat fryer had grease deposits in it apparently due to leakage from the frying well.
Recommendation: Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris. If leakage is occurring, then the unit shall be replaced or repaired.
Item No.: 26
Site: Other-MAIN GALLEY - SCULLERY
Violation: The main dishwashing machine was operating with final rinse sanitizing temperatures between 156-160oF while in use. (Corrected During Inspection)
Recommendation: Automatic dishwashing machines utilizing hot water for sanitizing shall operate at a minimum of 165oF (74oC) measured at dish level.
Item No.: 22
Site: Other-MAIN GALLEY - SCULLERY
Violation: Insure that pre-flushing of heavy food residue from dishware is done prior to racking the dishes to prevent food residue from being carried through the machine in the racks. Some food particles were noted on the clean landing table.
Recommendation:
Item No.: 29
Site: Other-MAIN PANTRY AND DINING RO
Violation: The drainlines from the coldtop tables were soiled with food residue.
Recommendation: Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris. A narrow brush shall be provided and used for cleaning the drain after each use.
Item No.: 29
Site: Other-VERANDAH FOOD SERVICE
Violation: The drainlines from the coldtop tables located in the dining room and along the service line were soiled with food debris and standing water.
Recommendation: Non-food contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles, and other debris.
Item No.: 6
Site: Other-SPA LOGS
Violation: During November and December 1995, many halogen residual readings for bromine were recorded in the log book as being less than the required minimum 2.0 parts per million. On some days, consecutive readings taken at 4-hour intervals, 4 times per day were shown to be less than 2.0 ppm. Some full day readings of 0.8 ppm and 1.3 ppm were noted.
Recommendation: Whirlpool, spa and hot tub water must be filtered and a free halogen residual of 2.0-5.0 ppm must be maintained at all times while the spa is open for use. If readings are found to be less than 2.0 ppm then the spa shall be taken out of service until corrective action is taken. It is recommended that CDC's "Interim Recommendations to Minimize Transmission of Legionnaires' Disease from Whirlpool Spas on Cruise Ships" dated January 23, 1995 be followed.
*Inspections scores of 85 or lower are NOT satisfactory